Davita Pin Oak Dialysis
A dialysis facility in Katy, Texas 77494
24968 Katy Ranch Rd Unit 500, Katy, Texas 77494. (281) 574-4387.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 2 deficiencies cited in the last three years
- 20 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Dec 17, 2024: a complaint inspection.
2 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
2 deficiencies in 1 month of the last 36. Last cited Jul 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jul 17, 2024: complaint inspection2 deficiencies
-
Receive Services Outlined In Poc
The inspectors’ words, 847 words
“PR-RECEIVE SERVICES OUTLINED IN POC CFR(s): 494.70(a)(12) The patient has the right to- (12) Receive the necessary services outlined in the patient plan of care described in §494.90; This Standard is not met as evidenced by: 10802 Based on observation, interview, and record review, the facility’s staff failed to administer patients’ hemodialysis treatment based on physician’s orders in 2 of 7 sampled patients; Patient #s 1, 3, Findings: Patient #1 On 07/16/2024 at 9:00 a.m. Patient #1 who is identified in the complaint investigation, was observed on the treatment floor of the facility at station # 13, hemodialysis machine #3. The patient was receiving hemodialysis treatment at a blood flow rate of 400 mls/ minute and dialysate flow rate of 700 mls/ minute. The patient was utilizing dialysate concentrate of 2 mEq potassium , 2.5 mEq calcium and bicarbonate of 31 mEq/L. At the request of the Surveyor, Registered Nurse (D) opened the panel of the hemodialysis machine which indicated a bicarbonate setting of 31 mEq/dl. Review of the patient’s clinical record located in the chairside computer revealed a physician’s order dated 7/11/2024 for bicarbonate setting of 37 mEq. The surveyor immediately notified Registered (D) that the patient’s hemodialysis machine was not set to deliver prescribed bicarbonate of 37 mEq. Registered Nurse (D) states “ I will change the setting.” Review of the treatment sheet located in the chairside computer revealed the patient’s hemodialysis treatment began at 6:45 a.m. with bicarbonate setting at 31 mEq/ L until the Surveyor notified Registered Nurse (D) of the incorrect setting on the patient’s hemodialysis machine. Patient#1 Dialysate flow rate Review of the patient#1’s treatment sheet dated 06/20/2024 revealed a prescription for blood flow rate of 400 mls/ minute and dialysate flow rate of 700 mls/ minute. Review of the patient’s clinical record revealed a physician’s order dated 07/11/2024 for blood flow rate of 400 mls/ minute and dialysate flow rate of 700 mls/ minute. Review of the patient’s treatment sheet dated 06/20/2024 revealed documentation that patient’s blood flow rate was maintained at 350 mls/ minute from 06:04 a.m. to 10:04 a.m., instead of 400 mls/minute as ordered by the patient’s physician. There was no justification documented why the patient’s blood flow rate was not maintained at the prescribed rate of 400 mls/ minute. Review of the patient’s treatment sheet revealed documentation by the patient care technician assigned to the patient, that the patient’s hemodialysis treatment was initiated by the patient care technician at 06:04 a.m. and continued at 10:04 a.m. Review of the treatment sheet revealed documentation by the registered nurse assigned to the patient that she verified the patient’s prescription at 06:12 a.m. There was no documented intradialytic assessment conducted by the registered nurse assigned to the patient during the patient’s hemodialysis treatment. Review of the registered nurse’s post treatment assessment revealed the following documentation: “pt tolerated treatment well, asymptomatic.” Treatment sheet dated 06/29/2024. Review of the patient#1’s treatment sheet dated 06/29/2024 revealed a prescription for blood flow rate of 400 mls/ minute and dialysate flow rate of 700 mls/ minute. Review of the patient’s treatment sheet dated 06/29/2024 revealed the patient blood flow rate was maintained at 350 mls/ minute from 08:01 a.m. to 10:31 a.m., instead of 400 mls/minute as ordered by the patient’s physician. There was no justification documented why the patient’s blood flow rate was not maintained at the prescribed rate of 400 mls/ minute. Review of the patient’s treatment sheet revealed documentation by the patient care technician assigned to the patient that the patient’s hemodialysis treatment was initiated by the patient care technician at 06:59 a.m. at a blood flow rate of 400 mls/ minute. At 8:01 a.m. the patient care technician decreased the patient’s blood flow rate to 350 mls/ minute and maintained it at 350 mls./ minute until 10:31 a.m. There was no documentation that the registered nurse assigned to the patient was informed of the decreased blood flow rate or that the registered nurse conducted an assessment on the patient after the patient’s blood flow rate was decreased by the patient care technician. On 07/16/2024 the Surveyor reviewed patient#1’s treatment sheets with the Facility’s Medical Clinical Support personnel who validated that the patient’s blood flow rate was not maintained at the prescribed rate. Patient #3 Review of the patient#3’s treatment sheet dated 07/11/2024 revealed a prescription for dialysate flow rate of 700 mls/ minute. Review of the patient’s treatment sheet dated 07/11/2024 revealed the patient’s dialysate flow rate was maintained at 500 mls/ minute instead of 700 mls/minute as ordered by the patient’s physician. Review of the patient’s treatment sheet revealed documentation by the patient care technician that the patient’s hemodialysis treatment was initiated by the patient care technician at 05:16 a.m. and continued at 8:55 a.m. Review of the treatment sheet revealed documentation by the registered nurse assigned to the patient that she verified the patient’s prescription at 06:54 a.m. Interview on 07/17/2024 at 9:57 a.m. with Registered Nurse (E ), the surveyor reviewed the patient’s record ( treatment sheet) with the Facility’s Registered Nurse. She states, “I missed it.””
-
Manage Anemia/H/H Measured Monthly
The inspectors’ words, 545 words
“POC-MANAGE ANEMIA/H/H MEASURED Q MO CFR(s): 494.90(a)(4) The interdisciplinary team must provide the necessary care and services to achieve and sustain the clinically appropriate hemoglobin/hematocrit level. The patient’s hemoglobin/hematocrit must be measured at least monthly. The dialysis facility must conduct an evaluation of the patient’s anemia management needs. This Standard is not met as evidenced by: 10802 Based on observation, interview, and record review, the facility’s staff failed to administer patients’ medication based on physician’s orders in 2 of 7 sampled patients; Patient #s 3, 4 Findings: Patient #3 On 07/16/2024 at 8:27 a.m. Patient #3 was observed at station #9, hemodialysis machine #18. The patient was receiving hemodialysis treatment at a blood flow rate of 300 mls minute and dialysate flow rate of 700 mls/ minute via a right double lumen central venous catheter. Observation revealed a 10 ml syringe was observed attached to the medication administration port of the external blood line. The lumen of the medication port was filled with residual intravenous Venofer from previous administration of the medication to the patient. Review of the patient’s clinical record (treatment sheet ) dated 7/16/2024 revealed a prescription for Venofer 50 mg intravenously one time a week. Review of the patient’s treatment sheet revealed documentation that the medication was administered to the patient by the registered nurse at 06:38 a.m. Review of the patient’s clinical record revealed a physician’s order dated 2/9/2024 for Venofer 50 mg one time a week. Subsequent observation on 07/16/2024 at 10.44 a.m. revealed the patient’s hemodialysis treatment was discontinued and the patient left the unit while the Venofer remained in the lumen of the syringe. The Surveyor immediately notified and showed the facility’s acting administrator the Venofer in the medication administration lumen of the medication port. The Facility’s acting administrator states “ it’s a lot.” He then informed the Surveyor that the registered nurse who administered the medication at left for the day. Patient #4 On 07/16/2024 at 8:40 a.m. Patient #4 was observed at station #11, hemodialysis machine #3. The patient was receiving hemodialysis treatment at a blood flow rate of 300 mls minute and dialysate flow rate of 700 mls/ minute via a right double lumen central venous catheter. Observation revealed a 10 ml syringe was observed attached to the medication administration port of the external blood line. The lumen of the medication port was filled with residual intravenous Venofer from previous administration of the medication to the patient. Review of the patient’s clinical record (treatment sheet ) dated 7/16/2024 revealed a prescription for Venofer 50 mg intravenously one time a week. Review of the patient’s treatment sheet revealed documentation that the medication was administered to the patient by the registered nurse at 06:39 a.m. Review of the patient’s clinical record revealed a physician’s order dated 3/14/2023 for Venofer 50 mg one time a week. Subsequent observation on 07/16/2024 at 10.40 a.m. revealed the patient’s hemodialysis treatment was discontinued and the patient left the unit while the Venofer remained in the lumen of the syringe. The Surveyor immediately notified and showed the Facility’s Acting Administrator the Venofer left in the in the lumen of the medication Port. The Facility’s Acting Administrator informed the surveyor that the registered nurse who administered the medication at left for the day.”
All 2 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Dec 17, 2024 | Complaint inspection | No deficiencies cited |
| Jul 17, 2024 | Complaint inspection | 2 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Aug 21, 2002.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- 2 deficiencies cited in the last three years came from inspections that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 20 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 32 dialysis facilities CMS lists in Fort Bend County, 29 have a star rating from CMS: 4 rated 5 of 5, 1 rated 4 of 5, 13 rated 3 of 5, 2 rated 2 of 5, 9 rated 1 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.