Hearth Record

Davita First Colony Dialysis Center

A dialysis facility in Sugar Land, Texas 77478

1447 Hwy 6 Suite #140, Sugar Land, Texas 77478. (281) 494-1465.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 4 deficiencies in 1 month of the last 36. Last cited Jan 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jan 26, 2024: a standard inspection.

4 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

4 deficiencies in 1 month of the last 36. Last cited Jan 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

4 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jan 26, 2024: standard inspection4 deficiencies
  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 359 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 22676 Based on observation, interview, facility policy review and review of Centers for Disease Control (CDC) guidance, the facility failed to ensure that the 13 out of 16 wall boxes (dispensing outlets) at dialysis stations and 10 out of 12 dialysis machines was cleaned and the buildup of white crystals and yellow substance removed. This deficient practice had the potential to cause bacteria to grow in the wall boxes and cause harm by infecting the 70 patients receiving in-center hemodialysis at the facility. Findings included: Observation of the wall boxes on 01/25/24 at 10:30 AM, at each dialysis station, stations numbered 1, 3, 6, 7, 9, 10, 11, 10, 11 and 12 revealed a dark yellow sediment with white sediment build-up on the wall boxes. During an interview on 01/25/24 at 10:30 AM, the Administrator 2 and Clinical Services Director 7, confirmed the wall boxes had a dark yellow with white crystal sediment build-up on the wall box. Review of facility’s policy titled, “Infection Control for Dialysis Facilities,” dated April 23, indicated, “ ...equipment including the dialysis delivery system ... wiped clean with bleach solution of the appropriate strength ...thought out the workday and after each treatment ...” Review of the “CDC Dialysis Safety” located on the CDC website at www.cdc.gov titled “Wall boxes and Drains” indicated, “All box surfaces should be disinfected at least daily (e.g., at the end of the day after all patients have dialyzed); cleaning and disinfection might be needed more frequently (e.g., when visibly dirty). Cleaning and disinfection of the wall box should be performed after the patient has left the station, and not during patient care activities ... More than one disinfectant wipe or application may be needed to ensure all wall box surfaces are visibly wet with disinfectant to achieve contact time specified by the manufacturer.””

    Rule V0122. Standard-level.

  • Environment: Secure And Restricted

    The inspectors’ words, 357 words

    “ENVIRONMENT-SECURE & RESTRICTED CFR(s): 494.40(a) 8 Environment: secure & restricted The water purification and storage system should be located in a secure area that is readily accessible to authorized users. The location should be chosen with a view to minimizing the length and complexity of the distribution system. Access to the purification system should be restricted to those individuals responsible for monitoring and maintenance of the system. This Standard is not met as evidenced by: 22676 Based on observation, interview, and policy review, the facility failed to restrict access to the water purification and storage system to only individuals responsible for monitoring and maintenance of the system on one of three survey days. Failure to restrict access to the water purification and storage system to only individuals responsible for monitoring and maintenance of the system had the potential to negatively impact the safety and well-being of the 77 in-center dialysis patients receiving treatments at this facility. Findings include: During tour of the facility on 01/25/24 at 10:00 AM, observed the door leading to the water purification system and the bicarb and acid storage area was locked with a coded entry. The locked area contained two rooms. On entry the room was a large area. Observed a second door that was secured with the same code, which opened into a room that contained the water purification system. During an interview on 01/25/24 at 10:00 AM, Biomed 6 confirmed access to the water purification and storage system was not restricted to only authorized users who were responsible for the monitoring and maintaining the system. Biomed 6 stated that all areas within the building use the same code as the water area.” During an interview on 01/25/24 at 11:00 AM, Administrator 2 confirmed that all staff were given the code to all coded areas, and it was the same as the water room code and the other doors in the facility. Review of the facility’s policy titled, “Water Treatment System Minimum Component Requirement,” dated October 2021, indicated, “Access to the water treatment system should be restricted to those personnel/trained teammates responsible for monitoring, maintenance of the system and supply ordering.””

    Rule V0184. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 258 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 22676 Based on review of glucometer logs, interview, facility policy review, and review of manufacturer’s instructions, the facility failed to ensure the glucometers were in the control range and follow manufacturer’s instructions for one of one glucometer used in the facility. This had the potential to provide inaccurate glucose results that could result in mistreated blood glucose levels to all 70 patients receiving care at the facility. Findings include: Review of Blood Glucose logs provided by the facility Administrator, for Glucometer (EE19100789) from 11/01/23 through 01/21/24 revealed the acceptable low blood glucose control range should be 94-126. On 12/09/23, the recorded low control was 127. During an interview on 01/25/24 at 1:35 PM, with the Facility Administrator 2 and the Manager of Clinical Services 7, he/she confirmed the staff did not repeat calibration of the abnormal low testing level. Review of the facility’s policy titled, “Embrace PRO Blood Glucose Monitoring System Quality Control” dated September 2020, revealed, “. . . 16. If control results fall outside the acceptable range the test must be repeated.” Review of the “Embrace Pro” blood glucose monitoring system manufactures instruction revision date 09/2020 revealed, “ ...p. eleven, if the “test fall outside the range printed on the test strip vial, repeat the test ...””

    Rule V0403. Standard-level.

  • Appropriateness Of Dialysis Rx

    The inspectors’ words, 253 words

    “PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 22676 Based on record reviews, interview, and policy review, the facility failed to follow the individualized dialysis (an artificial means of kidney function that removes the waste and excess fluid from the blood by passing through a filter) prescription as determined by the medical provider for one of seven sampled in-center patients (Patient (P) 21). Failure to follow the medical providers’ dialysis prescription had the potential to negatively impact the effectiveness of the prescribed dialysis treatments for the all 70 patients receiving in-center dialysis treatments at this facility. Findings include: Review of 21’s electronic medical record (EMR) revealed a prescribed blood flow rate (BFR) 350 milliliters per min (ml/min). Review of one of six “Post Treatment” flowsheets from 01/06/24 through 01/23/24, in the EMR indicated the following: On 01/02/24, the BFR was documented at 300 ml/min from 5:45 AM until 8:30 PM. There was no documented rationale for the change to the prescribed BFR. During an interview on 01/26/24 at 2:30 PM, the Administrator 2 and Manager of Clinical Services 7 confirmed the above findings and confirmed that staff did not follow the facility’s policy. Review of the facility’s policy titled, “Pre-Intra-Post Treatment Data Collection, Monitoring, and Assessment,” dated 10/23, revealed, “The Nursing assessment will be performed and documented ...Verification of the prescription including machine parameters ...””

    Rule V0503. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jan 26, 2024Standard inspection4 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on May 29, 2008.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis and a shift starting at 5 p.m. or later.
  • Doesn’t offer peritoneal dialysis and home hemodialysis training.
  • 13 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 5 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 55 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 32 dialysis facilities CMS lists in Fort Bend County, 29 have a star rating from CMS: 4 rated 5 of 5, 1 rated 4 of 5, 13 rated 3 of 5, 2 rated 2 of 5, 9 rated 1 of 5.
  • CMS rates this one 5 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.