Fmc Trussville
A dialysis facility in Birmingham, Alabama 35235
3671 Roosevelt Blvd, Birmingham, Alabama 35235. (205) 655-0961.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 14, 2026.
- 5of 5 CMS’s star rating
- 4of 5 patient survey rating
- 2 deficiencies cited in the last three years
- 20 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jul 17, 2025: a standard inspection.
2 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
When those deficiencies happened
2 deficiencies in 1 month of the last 36. Last cited Jul 2025. Most serious: Standard-level. The last 3 years, to Oct 19, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
Jul 17, 2025: standard inspection2 deficiencies
-
Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols
The inspectors’ words, 492 words
“IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 35949 Based on observation, interview, and facility policy review, the facility failed to ensure all environmental surfaces in the dialysis treatment stations were disinfected at the end of each dialysis treatment during 2 of 2 observations. This failure had the potential to negatively impact the safety and wellbeing of the 37 current patients who received dialysis treatments at the facility. Findings included: A facility policy titled, “Cleaning and Disinfecting the Dialysis Station,” dated 09/05/2023, indicated, “The Centers for Medicare and Medicaid Services (CMS) has regulations that in order to prevent cross contamination, a dialysis station must be cleaned and disinfected between dialysis patients. The chair and dialysis equipment are used by multiple patients during a treatment day and it is critical that these items be thoroughly cleaned and disinfected between uses.” The section of the policy titled “Definition” revealed that a “Dialysis Station” was defined as an “Area including the dialysis machine, chair/bed and other reusable equipment or supplies utilized during dialysis treatment, patient training, and/or patient clinic visits. Equipment in the dialysis station may include (but is not limited to) the following: - Dialysis machine/cycler and attachments such as IV [intravenous] pole, BP [blood pressure] cuff and hand sanitizer/holder, organizer - Chair/bed - [brand name of a water and dialysate preparation system] - Individual television and remote.” An observation of the hemodialysis treatment area on 07/14/2025 at 10:42 AM revealed Certified Clinical Hemodialysis Technician (CCHT) #5 failed to disinfect the sanitizer bottle and the bracket attached to the side of the dialysis machine while disinfecting Station 11. An observation of the hemodialysis treatment area on 07/14/2025 at 10:45 AM revealed CCHT #4 failed to disinfect the sanitizer bottle and the bracket attached to the side of the dialysis machine while disinfecting Station 8. During an interview on 07/14/2025 at 10:54 AM, CCHT #4 acknowledged she/he was trained and expected to disinfect all surfaces in the treatment stations after each dialysis treatment. During an interview on 07/14/2025 at 10:58 AM, CCHT #5 acknowledged she/he was trained and expected to disinfect all surfaces in the treatment stations after each dialysis treatment. During an interview on 07/14/2025 at 10:59 AM, the Clinical Manager confirmed staff were expected to disinfect all surfaces in the dialysis treatment stations after each dialysis treatment, including the sanitizer bottles and the brackets attached to the sides of the dialysis machines. During an interview on 07/17/2025 at 10:20 AM, the Medical Director confirmed staff were expected to disinfect all surfaces in the dialysis treatment stations after each dialysis treatment, including the sanitizer bottles and the brackets attached to the sides of the dialysis machines.”
-
Pe - Equipment Maintenance - Manufacturer’S Dfu
The inspectors’ words, 671 words
“PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 35949 Based on observation, interview, manufacturer’s instructions for use (IFU) review, and facility procedure review, the facility failed to follow the bloodline manufacturer’s IFU by not maintaining the arterial drip chamber fluid levels at approximately 90% full and the venous drip chamber fluid levels at approximately 70% full during 4 of 4 observations. Failure to follow the manufacturer’s IFU had the potential to result in equipment malfunction and/or failure and negatively impact the safety and wellbeing of the 37 current patients who received dialysis treatments at the facility. Findings included: A facility procedure titled, “Priming an Optiflux Single Use E-beam Dialyzer,” published 05/05/2025, indicated, “8. Fill the Pre-pump arterial chamber: Vent the chamber by loosening the cap and opening the clamp on the level adjust line. Fill chamber 85% - 95% full and tighten cap. Close the clamp on the level adjust line.” Further review indicated, “12. Fill venous chamber: Vent the chamber by loosening the cap and opening the clamp on the level adjust line. Fill chamber 65% - 75% full. Tighten cap and close clamp on the level adjust line when chamber is filled.” The manufacturer’s IFU titled, “CombiSet True Flow Series Hemodialysis Blood Tubing Set with Attached Priming Set and Transducer Protectors,” indicated, “During Treatment a. Periodically check the extracorporeal circuit for any evidence of possible separation or leaks. b. Do not allow the access or bloodline connections to be covered with a blanket or clothing during treatment. c. Maintain fluid level in arterial chamber at approximately 90% full and venous chamber at approximately 70% full. Levels may rise or drop during the treatment due to changes in pressure or flow rate. Readjust levels as needed. Air leaks will also cause the chamber levels to fluctuate.” Observation of the hemodialysis treatment area on 07/14/2025 at 10:30 AM revealed the arterial drip chamber fluid levels were approximately less than (<) 90% full in Stations 1, 4, 5, 6, 10, 12, 13, 14, 17, 18, 19, and 20, and approximately greater than (>) 70% full in Stations 1, 4, 5, 10, 13, 14, 17, 18, 19, and 20. Observation of the hemodialysis treatment area on 07/16/2025 at 11:37 AM and 11:45 AM revealed the arterial drip chamber fluid levels were approximately < 90% full in Stations 1, 2, 3, 10, 11, 12, 13, 15, 16, 17, 19, and 20, and approximately > 70% full in Stations 1, 2, 3, 7, 9, 10, 11, 12, 13, 15, 16, 17, 19, and 20. Observation of the hemodialysis treatment area on 07/16/2025 at 3:15 PM revealed the arterial drip chamber fluid levels were approximately < 90% full in Stations 2, 4, 8, and 18, and approximately > 70% full in Stations 2, 4, 7, 8, and 18. During an interview on 07/16/2025 at 3:15 PM in the treatment area with the Clinical Manager (CM) after review of the manufacturer’s IFU, the CM confirmed the drip chamber fluid levels were not maintained according to the manufacturer’s IFU. During an interview on 07/16/2025 at 4:15 PM, Registered Nurse (RN) #3 stated the drip chamber fluid levels should be “one third of the way” full. RN #3 confirmed the drip chamber fluid levels were not maintained according to the manufacturer’s IFU. During an interview on 07/16/2025 at 4:39 PM, Certified Clinical Hemodialysis Technician #5 stated the drip chambers should be “at least 80 [percent]” in the venous chamber and “90 [percent] in the arterial chamber. CCHT #5 confirmed the drip chamber fluid levels were not maintained according to the manufacturer’s IFU. During an interview on 07/17/2025 at 10:20 AM, the Medical Director confirmed the facility staff were expected to follow the manufacturer’s IFU for maintaining the drip chamber fluid levels during dialysis treatment and readjust as needed.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jul 17, 2025 | Standard inspection | 2 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Sep 28, 2016.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 20 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
- In CMS’s survey, patients rate its staff 4 of 5.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 5 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- Patients rate it 4 of 5 in CMS’s survey of in-center hemodialysis patients (31 interviews, Oct 18, 2024 to Jul 11, 2025): 91% rated the facility 9 or 10 out of 10.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 5 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | 4 of 5 |
How does it compare nearby?
- Of the 29 dialysis facilities CMS lists in Jefferson County, 27 have a star rating from CMS: 2 rated 5 of 5, 2 rated 4 of 5, 13 rated 3 of 5, 10 rated 2 of 5.
- CMS rates this one 5 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 19, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 19, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 14, 2026 and checked Oct 19, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 19, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.