Dci Birmingham
A dialysis facility in Birmingham, Alabama 35206
8713 Parkway East, Birmingham, Alabama 35206. (205) 838-5400.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 5of 5 CMS’s star rating
- Not rated patient survey rating
- 4 deficiencies cited in the last three years
- 16 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on May 21, 2025: a standard inspection.
4 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
4 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
May 21, 2025: standard inspection4 deficiencies
-
Ic - Wear Gloves/Hand Hygiene
The inspectors’ words, 240 words
“IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 22676 Based on observation, interview, and policy review, the facility failed to ensure proper hand hygiene was performed during central venous catheter access for one of one patient (Patient (P) 7) observed with a central venous catheter. Failure to perform proper hand hygiene has the potential to place all patients and visitors at risk for cross contamination. Findings include: During an observation on 05/19/25 at 11:15 AM, Registered Nurse (RN) 9 was observed accessing P7’s central venous catheter for dialysis treatment. RN9 repeatedly used the hand sanitizer that was mounted on the patient’s dialysis machine at Station 4 instead of using the hand sanitizer mounted on P7’s dialysis machine. During an interview on 05/19/25 at 11:30 AM, RN 9 confirmed the above findings. During an interview on 05/19/25 at 11:15 AM, Nurse Manager 3, who was present during the observation, confirmed the above findings. Review of the facility’s policy titled, “General Facility Infection Control,” dated 03/12/19 revealed, “. . . Items taken into the dialysis station should either be disposed of, dedicated for use on a single patient, or cleaned and disinfected before being taken to a common clean area or used on another patient . . .””
-
Ic - Items Taken To Station Disposed/Dedicated Or Disinfected
The inspectors’ words, 291 words
“IC-IF TO STATION=DISP/DEDICATE OR DISINFECT CFR(s): 494.30(a)(1)(i) Items taken into the dialysis station should either be disposed of, dedicated for use only on a single patient, or cleaned and disinfected before being taken to a common clean area or used on another patient. -- Nondisposable items that cannot be cleaned and disinfected (e.g., adhesive tape, cloth covered blood pressure cuffs) should be dedicated for use only on a single patient. -- Unused medications (including multiple dose vials containing diluents) or supplies (syringes, alcohol swabs, etc.) taken to the patient’s station should be used only for that patient and should not be returned to a common clean area or used on other patients. This Standard is not met as evidenced by: 22676 Based on observation, interview, and policy review, the facility failed to ensure the hemostats and clamps used in patient care were disinfected appropriately. This increased the risk of cross contamination for 36 of 36 patients receiving care at the facility. Findings include: During an observation on the treatment floor on 05/21/25 at 9:30 AM, the hemostats used in patient care were observed to be soaking in the disinfectant in the closed position versus the open position to ensure adequate disinfection of the interior surface of the clamp. During an interview on 05/21/25 at 9:40 AM, the Nurse Manager confirmed the clamps were to be in the open position when places in the disinfectant to ensure the inside of the clamps were adequately disinfected. Review of the facility’s policy titled, “Disinfection of Clamps,” dated 04/36/10, revealed, “ . . . As the clamps are used open them and observe for blood. If blood is found rinse them with tap water, place the clamps in the bucket of bleach . . .””
-
Ic - Handling Infectious Waste
The inspectors’ words, 275 words
“IC-HANDLING INFECTIOUS WASTE CFR(s): 494.30(a)(4)(i) [The facility must demonstrate that it follows standard infection control precautions by implementing-] (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the- (i) Handling, storage and disposal of potentially infectious waste; This Standard is not met as evidenced by: 22676 Based on observation, interview, and policy review, the facility failed to sanitize and disinfect trash receptables and empty trash bags between patients at five of five treatment stations (Stations 3, 4, 5, 6, and 8) observed. This had the potential to lead to cross contamination between all patients who dialyze at the dialysis stations. Findings include: During observation in the dialysis treatment room on 05/19/25 between 9:45 AM-11:30 AM, it was noted that the outside of the trash receptacles were not sanitized and disinfected between patients at Stations 3, 4, 5, 6, and 8. These trash receptacles were located at each station, touching each station between the chair and in front of dialysis machine. It was noted the trash bags were not emptied between patients. During an interview on 05/19/25 at 11:45 AM, the Nurse Manager, who was present during the observation, confirmed that the outside of the trash receptacles were not cleaned between patients and the trash bags were not emptied or changed between patients. Review of the facility’s policy titled, “General Facility Infection Control,” dated 03/12/19, revealed, “. . . Items taken into the dialysis station should either be disposed of, dedicated for use on a single patient. Or cleaned and disinfected before being taken to a common clean area or used on another patient . . .””
-
Pe - Building - Constructed/Maintained To Ensure Safety
The inspectors’ words, 187 words
“PE-BUILDING-CONSTRUCT/MAINTAIN FOR SAFETY CFR(s): 494.60(a) The building in which dialysis services are furnished must be constructed and maintained to ensure the safety of the patients, the staff and the public. This Standard is not met as evidenced by: 22676 Based on observation and interview, the facility failed to maintain the water room floor in a safe and clean condition to ensure the safety of the patients and staff and reduce the risk of infection for 36 of 36 patients receiving care at the facility. Findings include: Observations of the water room on 05/19/25 at 9:30 AM revealed the floor of the water room had rust stains, a black substance, and was partially sealed. The unsealed portion was porous concrete. An area approximately one foot by three feet in the center of the room was porous concrete with rust stains and a black substance. During an interview on 05/19/25 at 9:30 AM, Biomedical Technician 6 confirmed the flooring was porous concrete with black substance. During an interview on 05/21/25 at 9:30 AM, the Administrator stated the facility did not have a specific policy that covered the water room.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| May 21, 2025 | Standard inspection | 4 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Dec 18, 1997.
- Run as a non-profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Dialysis Clinic, Inc.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis and peritoneal dialysis.
- Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
- 16 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Dialysis Clinic, Inc. chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 5 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 5 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 29 dialysis facilities CMS lists in Jefferson County, 27 have a star rating from CMS: 2 rated 5 of 5, 2 rated 4 of 5, 13 rated 3 of 5, 10 rated 2 of 5.
- CMS rates this one 5 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.