Davita Birmingham North Dialysis
A dialysis facility in Birmingham, Alabama 35207
1917 32nd Avenue North, Birmingham, Alabama 35207. (205) 297-9052.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 2of 5 CMS’s star rating
- Not rated patient survey rating
- 3 deficiencies cited in the last three years
- 24 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jun 27, 2025: a standard inspection.
3 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
3 deficiencies in 1 month of the last 36. Last cited Jun 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jun 27, 2025: standard inspection3 deficiencies
-
Mixing Systems - Permanent Record/Verification Testing
The inspectors’ words, 527 words
“MIXING SYSTEMS-PERM RECORD/VERIF TEST CFR(s): 494.40(a) 5.4.4.1 Mixing systems: perm record/verification testing In addition to container labeling, there should be permanent records of batches produced. These records should include the concentrate formula produced, the volume of the batch, the lot numbers of powdered concentrate packages, the manufacturer of the powdered concentrate, the date and time of mixing, any test results, the person performing the mixing, the person verifying mixing and test results, and the expiration date (if applicable). 6.4.1 Mixing systems Acid and bicarbonate concentrates may be tested by using conductivity or by using a hydrometer. Concentrates should not be used or transferred to holding tanks or distribution systems until all tests are completed. The test results and verification that they meet all applicable criteria should be recorded and signed by the individuals performing the tests. This Standard is not met as evidenced by: 22676 Based on observation, record review, interview, and review of the facility’s policy, the facility staff failed to test the bicarbonate solution (part of the solutions used in the dialysis treatment) prior to releasing the solution to the treatment floor as required for three months of three months of bicarbonate mixing records reviewed from (04/02/25-06/25/25). This deficient practice had the likelihood of affecting all 44 in-center hemodialysis patients receiving care at the facility. Findings include: During a review of the bicarbonate mixing log from 04/02/25 through 06/25/25 revealed there was no documentation of conductivity or specific gravity on the log. An interview with Biomedical Technician on 06/25/25 at 9:15 AM confirmed staff does not record the testing of the bicarb on the log, and they do not test the bicarbonate prior to releasing the solution to the holding tank. The Biomedical Technician confirmed the manufacturer did not specify a conductivity or specific gravity range. A review of the manufacturer’s instruction for “Nipro Bicarbonate Powder” revealed the manufacturer had no recommendations regarding the testing of reconstituted bicarbonate concentrate for conductivity, specific gravity, or pH (acidity or alkalinity of a solution). A review of the facility’s policy titled, “Bicarbonate Concentrate Mixing System” dated 09/24, revealed the following, “All bicarbonate concentrate will be performed in accordance with the bicarbonates manufacturer’s recommendations.” The federal regulations adopted the “ANSI/AAMIRD52:2004” which gives guidance on the mixing of bicarbonate solutions revealed the following, “5.4.4.1 Mixing systems: perm record/verification testing. In addition to container labeling, there should be permanent records of batches produced. These records should include the concentration formula produced, the volume of the batch, the lot numbers of powdered concentrate packages, the manufacturer of the powdered concentrate, the date and time of mixing, any test results, the person performing the mixing, the person verifying mixing and test results, and the expiration date (if applicable). 6.4.1 Mixing systems- Acid and bicarbonate concentrates may be tested by using conductivity or by using a hydrometer. Concentrates should not be used or transferred to holding tanks or distribution systems until all tests are completed. The test results and verification that meet all applicable criteria should be recorded and signed by the individuals performing the tests.” The facility failed to have a policy that sets the test range for the facility staff to follow.”
-
Achieve Adequate Clearance
The inspectors’ words, 420 words
“POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 22676 Based on record review, interview, and policy review, the facility failed to follow the individualized dialysis plan (an artificial means of kidney function that removes the waste and excess fluid from the blood by passing through a filter) by following the physician prescription as determined by the medical provider for three of five sampled in-center dialysis patients (Patient (P1), P3 and P5). Failure to follow the medical providers’ dialysis prescription had the potential to negatively impact on the effectiveness of the prescribed dialysis treatments for all 44 patients receiving in-center dialysis treatments at this facility. Findings include: 1. Review of P1’s “Treatment Detail Report” in the electronic medical record (EMR) revealed a prescribed Blood Flow Rate (BFR) of 450 milliliters per minute (ml/min). Review of one of six flowsheets from 06/11/25 through 06/23/25 indicated the following: a. On 06/16/25 from 5:54 AM until 9:00 AM, the BFR was documented at 400 ml/min. There was no documentation for the change to the prescribed BFR. 2. Review of P3’s “Treatment Detail Report” in the EMR revealed a prescribed BFR of 450 ml/min. Review of one of six flowsheets from 06/11/25 through 06/23/25 indicated the following: a. On 06/16/25 from 1:01 PM until 2:36 PM, the BFR was documented at 395 ml/min. b. On 06/20/25 from 11:01 AM until 2:14 PM the BFR was documented at 400 ml/min. c. On 06/23/25 from 11:01 AM until 2:30 PM the BFR was documented at 400 ml/min. There was no documentation for the change to the prescribed BFR. 3. Review of P5’s “Treatment Detail Report” in the EMR revealed a prescribed BFR 400 ml/min. Review of one of six flowsheets from 06/11/25 through 06/23/25 indicated the following: a. On 06/16/25 from 6:01 AM until 9:20 AM, the BFR was documented at 300 ml/min. There was no documentation for the change to the prescribed BFR. During an interview on 06/27/25 at 11:30 AM, the Administrator confirmed the above findings, and that staff did not follow the physician’s order for dialysis treatment. Review of the facility’s policy titled, “Pre-Intra-Posttreatment Data, Collection, Monitoring and Nursing Assessment,” dated April 2024, states identity, prescription, and machine settings are verified by teammate ... f. Blood flow rate ...”
-
Medical Records - Complete, Accurate, Accessible
The inspectors’ words, 243 words
“MR-COMPLETE, ACCURATE, ACCESSIBLE CFR(s): 494.170 The dialysis facility must maintain complete, accurate, and accessible records on all patients, including home patients who elect to receive dialysis supplies and equipment from a supplier that is not a provider of ESRD services and all other home dialysis patients whose care is under the supervision of the facility. This Standard is not met as evidenced by: 22676 Based on interview, document review, and policy review, the facility failed to prevent the staff from obliterating numbers when identifying an incorrect entry in a record one day of 37 days of Citric Acid Records reviewed. Failure to correct the records correctly has the potential to affect the release of information for all 44 patients receiving treatments at this facility. Findings include: Review of the facility’s document titled, “Water and testing Devices Procedure” for the “2% Citric Acid Mixing Log” on 06/26/25 at 11:30 PM, it was identified that on 04/07/25 under the column titled “Lot Numbers” the staff obliterated by writing over a number and wrote another number in the column titled “Container Labeled with Date/Time and initial.” In an interview with the Administrator on 06/26/25 at 11:30 AM, it was confirmed an obliteration was done to a recorded number and that staff failed to follow the facility policy. Review of the facility’s policy titled, “Medical Record Corrections” states, “No paper medical record entry is to be erased (including the use of correction fluid), obliterated, altered or destroyed.””
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jun 27, 2025 | Standard inspection | 3 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Aug 1, 1998.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 24 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, worse than expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, worse than expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 2 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 29 dialysis facilities CMS lists in Jefferson County, 27 have a star rating from CMS: 2 rated 5 of 5, 2 rated 4 of 5, 13 rated 3 of 5, 10 rated 2 of 5.
- CMS rates this one 2 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing