Hearth Record

Pontiac General Hospital

A psychiatric hospital in Pontiac, Michigan 48341

461 W Huron Street, Pontiac, Michigan 48341. (248) 857-7200.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 20, 2026.

The last 24 months 10 deficiencies in 1 month of the last 36. Last cited Jul 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean2
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jul 7, 2026: a complaint inspection.

10 deficiencies cited in the last three years.

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

When those deficiencies happened

10 deficiencies in 1 month of the last 36. Last cited Jul 2025. Most serious: Standard-level. The last 3 years, to Nov 5, 2026.

10 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 Dec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOctNov

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Jul 23, 2025: standard inspection6 deficiencies
  • Patient Rights: Care In Safe Setting

    The inspectors’ words, 256 words

    “PATIENT RIGHTS: CARE IN SAFE SETTING CFR(s): 482.13(c)(2) The patient has the right to receive care in a safe setting. This Standard is not met as evidenced by: 45246 Based on observation, interview and record review, the facility failed to ensure the door was locked to the nurses’ station resulting in the potential for an unsafe environment and potential for negative outcomes for all patients receiving care on the unit. Findings include: During the initial tour of the facility, on 07/21/25 at 1037, the nurses’ station door on 5 South unit was observed unlocked. Patients were observed walking the hallway while the door was unlocked. Nurses’ station area had easily accessible office supplies, telephone, computers and equipment cords, and a heavy-duty metal paper punch. On 07/22/25 at 0958, during tour of the 5 South unit, nurses’ station door was observed unlocked. Registered nurse, Staff O, was present in the area and was interviewed regarding safety on the unit. Staff O was asked if the door to nurses’ station needs to be locked. She stated “yes”. Mental health technician was observed on the unit making safety rounds. On 07/22/25 at 1020 Chief Compliance Officer, Staff A, was interviewed regarding the unlocked door. Staff A confirmed that the door has to be locked. Facility policy “Precautions and Level of Monitoring” dated 5/10/21 and revised 8/12/24 was reviewed and revealed: “IV. The MHT (mental health technician) will: N. Identify and report any findings while conducting observation rounds: 2. Ensure doors that are to be locked are, in fact, locked”.”

    Rule A0144. Standard-level.

  • Nursing Care Plan

    The inspectors’ words, 550 words

    “NURSING CARE PLAN CFR(s): 482.23(b)(4) The hospital must ensure that the nursing staff develops, and keeps current, a nursing care plan for each patient that reflects the patient’s goals and the nursing care to be provided to meet the patient’s needs. The nursing care plan may be part of an interdisciplinary care plan. This Standard is not met as evidenced by: 48772 Based on interview and record review, the facility failed to establish an individualized plan of care for 2 (P-16, P-18) of 20 patients reviewed, resulting in the potential for unmet care needs and negative outcomes for these patients. Findings include: P-16: This 18-year-old female was admitted to the facility on 1/3/25 with diagnoses of brief psychotic disorder, rule out schizoaffective disorder, bipolar type, intellectual and developmental disabilities, and attention deficit hyperactivity disorder. Admission was petitioned by P-16’s mother, who is also her guardian. During record review on 7/22/25, it was noted that the initial psychological evaluation dated 1/4/25, stated, “intelligence is below average based on history, grammar, and speech.” The master treatment plan dated 1/3/25 included three problems: aggression, altered thought process, and potential for fall resulting injury which was added on 1/14/25. The treatment plan failed to include intellectual and developmental disabilities or any barriers that could potentially impact learning, understanding, or care. This finding was reviewed and acknowledged by the Director of Nursing (Staff F) during an interview on 7/22/25 at 1200. 50585 On 7/22/2025 at 1345, P-18’s medical record was reviewed with Director of Quality Staff H. P-18 was admitted on 2/27/2025 for schizoaffective disorder and had a past medical history that included “Significant for sleep apnea, type 2 diabetes, hypertension, hyperlipidemia, and asthma.” On 2/27/2025, P-18’s Master Treatment plan included ten listed problems including diabetes mellitus and asthma/COPD (chronic obstructive pulmonary disease). On 2/27/2025, P-18 had individual treatment plans developed for diabetes with a target date on 3/13/25 and asthma with a target date of 3/13/25. On 3/7/2025, P-18’s individual plan of service progress summary had 4 identified problems (Altered thought process, Danger to self, Borderline Personality Traits, and Ineffective Coping) and there was no documentation or updates for P-18’s diabetes and asthma problems. On 7/23/2025 at 1145, P-18’s medical record was reviewed with Nurse Staff O and Staff O confirmed that the individual plan of service progress summary on 3/7/25 should have included information on diabetes and asthma. The facility’s policy titled Individualized Treatment Plan dated 12/18/2024 stated, “Based on the psychiatric evaluation and the Nursing Assessment, the Nurse initiates the ITP (individual treatment plan) by listing identified problems, strengths, and weaknesses. The problem list is developed from intake information, the medical/physical History and Physical, the Nursing Assessment, an initial interview with the patient and/or family, and any other assessments already completed.” The policy also revealed “ITPs will be reviewed and revised at least every seven (7) days and as needed in response to assessments conducted the multidisciplinary team and changes in a patient’s condition. Record progress or lack of progress for each short term goal. Determine the extent to which the interventions were implemented and the extent to which the goals were accomplished. Discuss any modifications that should be made to the interventions or goals and give a narrative statement describing progress or response to the treatment intervention in the lines provided.””

    Rule A0396. Standard-level.

  • Pharmacy Administration

    The inspectors’ words, 365 words

    “PHARMACY ADMINISTRATION CFR(s): 482.25(a) [§482.25 Condition of Participation: Pharmaceutical Services .....The medical staff is responsible for developing policies and procedures that minimize drug errors. This function may be delegated to the hospital’s organized pharmaceutical service.] §482.25(a) Standard: Pharmacy Management and Administration The pharmacy or drug storage area must be administered in accordance with accepted professional principles. This Standard is not met as evidenced by: 50585 Based on observation, interview, and record review, the facility failed to maintain the cleanliness of 1 of 2 medication refrigerators observed and failed to ensure the digital thermometers for recording the temperatures for the medication refrigerators and medication freezer were within the due dates for calibration for 3 of 3 thermometers observed resulting in the increased likelihood of negative consequences for all patients. Findings include: On 7/21/2025 at 1000 during a tour of the main pharmacy, two digital thermometers for recording medication refrigerator and freezer temperatures were observed to be past their listed calibration due dates. The thermometer connected to the medication refrigerator had a due date 7/13/2025 and the thermometer connected to the medication freezer had a due date of 2/5/03. Director of Pharmacy Staff G confirmed the findings at the time of discovery. On 7/21/2025 at 1010, during an inspection of the medication refrigerator in the main pharmacy, a black substance was observed along the inside rubber lining on top of the medication refrigerator door. Staff G was queried what was that substance, and they revealed it looks like “mold” and confirmed the findings at the time of discovery. On 7/21/2025 at 1045, during a tour of the 5 North medication room, the digital thermometer connected to the medication refrigerator was observed to have a calibration due date July 20, 2020. Staff G confirmed the findings at the time of discovery. According to the facility’s policy “Medication Management,” dated 1/13/2025, “Medications are stored under necessary conditions to ensure stability and in the most ready-to-administer forms available, when feasible, Temperature readings must be taken daily or twice a day if vaccines are stored at the location.” The policy also revealed that “All medication storage areas are inspected periodically to ensure proper medication storage as per Department of Pharmacy policy.””

    Rule A0491. Standard-level.

  • Maintenance Of Physical Plant

    The inspectors’ words, 560 words

    “MAINTENANCE OF PHYSICAL PLANT CFR(s): 482.41(a) The condition of the physical plant and the overall hospital environment must be developed and maintained in such a manner that the safety and well-being of patients are assured. This Standard is not met as evidenced by: 43001 Based upon observation, record review and interview, the facility failed to maintain chilled water piping, proper exhaust ventilation and air pressure relationships and clean ceiling tiles resulting in potential failure of the chilled water system and spread of infectious agents. Findings include: 1. At 1054 on 7/21/25 during a tour of the power plant, it was observed that the chilled water supply line was leaking, with the leak being directed right into a drain on the floor that was overflowing and not draining at the speed the water was being supplied from the leak. The chilled water return line was also leaking from the pump assembly onto the floor. Staff E was asked what the situation with the chilled water piping was and they explained that the supply line pump failed in February of this year and the return line was now being used temporarily as the supply line. The replacement part was in the power plant ready to be installed for a week or so at the time of the observation, but they have not been able to replace the part without shutting the hospital down. When Staff E was asked when the return line started leaking they said recently, but they were not concerned that that leak was a serious risk of failure for the chilled water system and were not anticipating on fixing it until October when the next anticipated hospital shut down was. 2. At 1201 on 7/21/25 during a tour of the 5th floor north wing of the hospital, it was observed that the soiled utility room did not have a negative air pressure relationship with the respect to the corridor after performing the tissue test at the base of the door. Staff E was asked if there was an issue with the exhaust fan serving this room and they stated they weren’t aware of an issue. A tissue was also placed on the vent where the exhaust should be pulling air from the room and it was not exhausting at all at the vent. Record review showed that there were no exhaust fans out of operation and they all were working properly on the last preventative maintainance check, around 7/1/25. 3. At 1006 on 7/22/25 during a tour of the 4th floor south wing of the hospital, it was observed that soiled utility room 475 did not have a negative air pressure relationship with respect to the corridor while performing the tissue test at the base of the door. Staff E was asked when this fan was not operating correctly and they stated that they were not aware that this was not working correctly. 4. At 1015 on 7/22/25 during a tour of the 4th floor south wing of the hospital, 4 stained ceiling tiles were observed in the dining room 461 and storage room adjacent to the dining room. Staff E was asked why the ceiling tiles were stained and they stated that their boiler recently failed which caused excessive humidity to condensate in the HVAC system in the hospital and was dripping water down on the ceiling tiles.”

    Rule A0701. Standard-level.

  • Facilities, Supplies, Equipment Maintenance

    The inspectors’ words, 328 words

    “FACILITIES, SUPPLIES, EQUIPMENT MAINTENANCE CFR(s): 482.41(c)(2) Facilities, supplies, and equipment must be maintained to ensure an acceptable level of safety and quality. This Standard is not met as evidenced by: 22960 Based on observation, interview, and record review, the facility failed to maintain kitchen equipment in proper working order, resulting in the potential for the backflow of contaminates into equipment. This deficient practice had the potential to affect all patients in the facility. Findings include: On 7/22/25 at 9:30 AM, the ice machine drain lines were observed to extend down below the flood level rim of the floor drain. When queried at that time, Consultant Registered Dietitian Staff BB provided no explanation. According to the Food & Drug Administration (FDA) 2022 Model Food Code section 5-202.13 Backflow Prevention, Air Gap, “An air gap between the water supply inlet and the flood level rim of the PLUMBING FIXTURE, EQUIPMENT, or nonfood EQUIPMENT shall be at least twice the diameter of the water supply inlet and may not be less than 25 mm (1 inch).” According to the Food & Drug Administration (FDA) 2022 Model Food Code, Section 5-402.11 Backflow Prevention, “(A) Except as specified in (B), (C), and (D) of this section, a direct connection may not exist between the sewage system and a drain originating from equipment in which food, portable equipment, or utensils are placed.” On 7/22/25 at 11:30 AM, the following pieces of kitchen equipment were observed with “Out of Order” signs: The dish machine, Traulsen reach-in cooler #2, #14 and #15. When queried at that time, Consultant Registered Dietitian Staff BB stated the plan was to repair the equipment, but that they are waiting on funding. According to the Food & Drug Administration (FDA) 2022 Model Food Code section 6-501.114 Maintaining Premises, Unnecessary Items and Litter, “The PREMISES shall be free of: (A) Items that are unnecessary to the operation or maintenance of the establishment such as EQUIPMENT that is nonfunctional or no longer used;”.”

    Rule A0724. Standard-level.

  • Infection Control Program

    The inspectors’ words, 615 words

    “INFECTION CONTROL PROGRAM CFR(s): 482.42(a)(1) The hospital infection prevention and control program, as documented in its policies and procedures, employs methods for preventing and controlling the transmission of infections within the hospital and between the hospital and other institutions and settings; This Standard is not met as evidenced by: 22960 Based on observation, interview, and record review, the facility failed to prepare food in accordance with professional standards for food service safety. This deficient practice has the potential to result in food borne illness among all patients that consume food from the kitchen. Findings include: On 7/22/25 at 10:00 AM, the Consultant Registered Dietitian (RD) Staff BB was queried regarding the lunch menu for the current day. Staff BB stated that Dietary Manager (DM) Staff CC was currently at the store purchasing the food items to be served for that day’s lunch meal. On 7/22/25 at 11:00 AM, DM Staff CC was observed entering the kitchen, carrying numerous grocery bags. DM Staff CC was observed placing the bags on the food preparation table. DM Staff CC then donned an apron, and began preparing the food items for lunch service, without first performing hand washing. On 7/22/25 at 11:25 AM, when queried, Consultant RD Staff BB confirmed that staff should be washing their hands upon entering the kitchen. Record review of standard of practice in the 2022 FDA Food Code noted: “Section 2-301.14 When to Wash. Food employees shall clean their hands and exposed portions of their arms as specified under § 2-301.12 immediately before engaging in food preparation including working with exposed food, clean equipment and utensils, and unwrapped single-service and single-use articles P and: (A) After touching bare human body parts other than clean hands and clean, exposed portions of arms; P (B) After using the toilet room; P (C) After caring for or handling service animals or aquatic animals as specified in 2-403.11(B); P (D) Except as specified in 2-401.11(B), after coughing, sneezing, using a handkerchief or disposable tissue, using tobacco, eating, or drinking; P (E) After handling soiled equipment or utensils; P (F) During food preparation, as often as necessary to remove soil and contamination and to prevent cross contamination when changing tasks; P (G) When switching between working with raw food and working with ready-to-eat food; P (H) Before donning gloves for working with food; P and (I) After engaging in other activities that contaminate the hands.” On 7/22/25 at 11:15 AM, DM Staff CC was observed slicing zucchini to be served for the lunch meal. When finished, DM Staff CC rinsed the knife under running water at the food prep sink, dipped the knife blade in the sanitizer bucket (which also contained a wiping cloth), and placed the knife back into the knife rack. On 7/22/25 at 11:25 AM, DM Staff CC was queried about the washing of the knife used to cut the zucchini. DM confirmed that the knife was rinsed in the sanitizer bucket and then put away. Record review of standard of practice in the 2022 FDA Food Code noted: “Section 4-303.11 Cleaning Agents and Sanitizers, Availability (A) Cleaning agents that are used to clean EQUIPMENT and UTENSILS as specified under Part 4-6, shall be provided and available for use during all hours of operation. P” Record review of standard of practice in the 2022 FDA Food Code noted: “Section 4-501.17 Warewashing Equipment, Cleaning Agents. When used for WAREWASHING, the wash compartment of a sink, mechanical warewasher, or wash receptacle of alternative manual WAREWASHING EQUIPMENT as specified in 4-301.12(C), shall contain a wash solution of soap, detergent, acid cleaner, alkaline cleaner, degreaser, abrasive cleaner, or other cleaning agent according to the cleaning agent manufacturer’s label instructions. Pf””

    Rule A0749. Standard-level.

Jul 22, 2025: standard inspection4 deficiencies
  • Initial Comments - Not A Deficiency Citation

    The inspectors’ words, 148 words

    “On July 21 and 22, 2025, a Life Safety Initial Certification Survey was conducted by the Michigan Department of Licensing and Regulatory Affairs. At the survey, Pontiac General Hospital was found in substantial compliance with the requirements for participation in Medicare/Medicaid and the applicable provisions of the 2012 Edition of the National Fire Protection Association (NFPA) 101, Life Safety Code (LSC), Chapter 19 Existing Health Care. This 7 story facility with a walk-out basement was determined to be at a minimum of Type II (222) construction, is fully protected by an automatic sprinkler system in the CMS certified areas and is separated by a 2 hour assembly from the non-certified use areas. The facility was constructed in 1980. The facility has 124 certified beds located on the 4th, 5th, and 6th floors and are for Hospital-Psych use only. At the time of the survey the census was 4.”

    Rule K0000. Standard-level.

  • Egress Doors

    The inspectors’ words, 487 words

    “Egress Doors CFR(s): NFPA 101 Egress Doors Doors in a required means of egress shall not be equipped with a latch or a lock that requires the use of a tool or key from the egress side unless using one of the following special locking arrangements: CLINICAL NEEDS OR SECURITY THREAT LOCKING Where special locking arrangements for the clinical security needs of the patient are used, only one locking device shall be permitted on each door and provisions shall be made for the rapid removal of occupants by: remote control of locks; keying of all locks or keys carried by staff at all times; or other such reliable means available to the staff at all times. 18.2.2.2.5.1, 18.2.2.2.6, 19.2.2.2.5.1, 19.2.2.2.6 SPECIAL NEEDS LOCKING ARRANGEMENTS Where special locking arrangements for the safety needs of the patient are used, all of the Clinical or Security Locking requirements are being met. In addition, the locks must be electrical locks that fail safely so as to release upon loss of power to the device; the building is protected by a supervised automatic sprinkler system and the locked space is protected by a complete smoke detection system (or is constantly monitored at an attended location within the locked space); and both the sprinkler and detection systems are arranged to unlock the doors upon activation. 18.2.2.2.5.2, 19.2.2.2.5.2, TIA 12-4 DELAYED-EGRESS LOCKING ARRANGEMENTS Approved, listed delayed-egress locking systems installed in accordance with 7.2.1.6.1 shall be permitted on door assemblies serving low and ordinary hazard contents in buildings protected throughout by an approved, supervised automatic fire detection system or an approved, supervised automatic sprinkler system. 18.2.2.2.4, 19.2.2.2.4 ACCESS-CONTROLLED EGRESS LOCKING ARRANGEMENTS Access-Controlled Egress Door assemblies installed in accordance with 7.2.1.6.2 shall be permitted. 18.2.2.2.4, 19.2.2.2.4 ELEVATOR LOBBY EXIT ACCESS LOCKING ARRANGEMENTS Elevator lobby exit access door locking in accordance with 7.2.1.6.3 shall be permitted on door assemblies in buildings protected throughout by an approved, supervised automatic fire detection system and an approved, supervised automatic sprinkler system. 18.2.2.2.4, 19.2.2.2.4 This Standard is not met as evidenced by: 38040 Based on observation and interview, the facility failed to ensure doors in a required means of egress are not equipped with a latch or lock that requires the use of a tool or key from the egress side unless meeting the special locking arrangements for clinical needs in accordance with 19.2.2.2.5.1 and 19.2.2.2.6. This deficient practice could affect 4 out of 4 occupants in the event of a fire emergency. Findings Include: On July 21, 2025, at approximately 10:00 AM, observation revealed the facility has placed unapproved special locking devices on all egress doors located in the facility’s lobby. A key card swipe pad was observed in place and needed to exit the facility. The lobby area is for business use only and not for patient care. The Facility Maintenance Director and the Hospital Chief Operating Officer (COO) confirmed these findings during interview at the time of observation.”

    Rule K0222. Standard-level.

  • Hazardous Areas - Enclosure

    The inspectors’ words, 301 words

    “Hazardous Areas - Enclosure CFR(s): NFPA 101 Hazardous Areas - Enclosure Hazardous areas are protected by a fire barrier having 1-hour fire resistance rating (with 3/4 hour fire rated doors) or an automatic fire extinguishing system in accordance with 8.7.1 or 19.3.5.9. When the approved automatic fire extinguishing system option is used, the areas shall be separated from other spaces by smoke resisting partitions and doors in accordance with 8.4. Doors shall be self-closing or automatic-closing and permitted to have nonrated or field-applied protective plates that do not exceed 48 inches from the bottom of the door. Describe the floor and zone locations of hazardous areas that are deficient in REMARKS. 19.3.2.1, 19.3.5.9 Area Automatic Sprinkler Separation N/A a. Boiler and Fuel-Fired Heater Rooms b. Laundries (larger than 100 square feet) c. Repair, Maintenance, and Paint Shops d. Soiled Linen Rooms (exceeding 64 gallons) e. Trash Collection Rooms (exceeding 64 gallons) f. Combustible Storage Rooms/Spaces (over 50 square feet) g. Laboratories (if classified as Severe Hazard - see K322) This Standard is not met as evidenced by: 38040 Based on observation and interview, the facility failed to provide hazardous areas protected by a fire barrier having 1-hour fire resistance rating (with 3/4 hour fire rated doors) or an automatic fire extinguishing system in accordance with 19.3.5.9. Doors shall be self-closing or automatic-closing. This deficient practice could affect 2 out of 4 occupants in the event of a fire emergency. Findings Include: On July 22, 2025, at approximately 10:00 AM, observation revealed the facility failed to install a required automatic closer on the storage closet #613. The closet will be used for combustible storage and is open to the patient hallway. The Facility Maintenance Director and the Hospital Chief Operating Officer (COO) confirmed these findings during interview at the time of observation.”

    Rule K0321. Standard-level.

  • Sprinkler System - Installation

    The inspectors’ words, 239 words

    “Sprinkler System - Installation CFR(s): NFPA 101 Spinkler System - Installation 2012 EXISTING Nursing homes, and hospitals where required by construction type, are protected throughout by an approved automatic sprinkler system in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems. In Type I and II construction, alternative protection measures are permitted to be substituted for sprinkler protection in specific areas where state or local regulations prohibit sprinklers. In hospitals, sprinklers are not required in clothes closets of patient sleeping rooms where the area of the closet does not exceed 6 square feet and sprinkler coverage covers the closet footprint as required by NFPA 13, Standard for Installation of Sprinkler Systems. 19.3.5.1, 19.3.5.2, 19.3.5.3, 19.3.5.4, 19.3.5.5, 19.4.2, 19.3.5.10, 9.7, 9.7.1.1(1) This Standard is not met as evidenced by: 36613 Based on observation and interview, the facility failed to ensure hospitals where required by construction type are protected throughout by an approved automatic sprinkler system in accordance with NFPA 13. This deficient practice could affect 4 out of 4 occupants in the event of a fire emergency. Findings Include: On July 22, 2025, at approximately 12:30 PM observation revealed open grate ceiling tiles in the 4th floor pantry room 476. This will allow heat to bypass the wet fire suppression system sprinkler head. No sprinkler heads are installed above the open grate ceiling. These findings were confirmed thorough interview with the maintenance director at the time of observation.”

    Rule K0351. Standard-level.

All 4 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Jul 7, 2026Complaint inspectionNo deficiencies cited
Apr 9, 2026Complaint inspectionNo deficiencies cited
Jul 23, 2025Standard inspection6 deficiencies cited
Jul 22, 2025Standard inspection4 deficiencies cited

How do patients fare?

  • CMS gives no overall : “Data are shown only for hospitals that participate in the Inpatient Quality Reporting (IQR) and Outpatient Quality Reporting (OQR) programs.”
  • CMS publishes no patient survey results for it.
Ratings and measures, as published
MeasureRating
Overall ratingCMS’s overall hospital quality star rating, 1 to 5Not rated
Patient survey ratingCMS star rating from its survey of the hospital’s patients (HCAHPS), 1 to 5Not rated

Is it certified, and in good standing?

  • Medicare-certified psychiatric hospital since Sep 25, 2025.
  • Ownership: proprietary.
  • It is accredited by The Joint Commission, whose surveys stand in for the state’s routine inspections.
  • No deficiency on record in the last three years.
  • Proprietary.
Source:

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for hospitals.
  • CMS’s HAC Reduction Program file has no result for it: the program covers general acute care hospitals Medicare pays under its inpatient prospective payment system.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, Hospital-Acquired Condition (HAC) Reduction Program. Released Aug 13, 2026. Updated yearly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

What do patients say about their care?

  • CMS doesn’t publish staffing levels for hospitals.
Source:

CMS, Patient survey (HCAHPS) - Hospital and Timely and Effective Care - Hospital. Released Aug 13, 2026. Updated quarterly.

Who owns it?

  • SANT Partners LLC owns 80% directly since May 1, 2016.
  • Axiom Management Group LLC runs it.
  • 10 owners or officers are people: Sanyam Sharma (owns 5% or more through other companies, 80%); Surindar K Jolly (owns 5% or more directly, 15%); Jawad Shah (owns 5% or more directly, 5%); Priyamvada Sinvhal-Sharma (corporate officer, 0%); Priyamvada Sinvhal-Sharma (corporate director, 0%); Sanyam Sharma (corporate officer, 0%); Sanyam Sharma (corporate director, 0%); Sanyam Sharma (runs it (operational or managerial control), 0%); Lalit Arora (corporate officer, 0%); Surindar K Jolly (corporate director, 0%).
  • CMS’s Provider of Services file records no change of ownership.
  • No private-equity firm among the owners CMS lists.
  • No real-estate investment trust among the owners CMS lists.
Source:

CMS, Hospital All Owners and Hospital Enrollments. Released Sep 29, 2026. Updated monthly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

Organisations CMS lists
OrganisationRoleShareSince
SANT Partners LLCOwns 5% or more directly80%May 1, 2016
Axiom Management Group LLCRuns it (operational or managerial control)0%May 1, 2017

How does it compare nearby?

  • Of the 14 hospitals CMS lists in Oakland County, 9 have an overall star rating from CMS: 2 rated 4 of 5, 5 rated 3 of 5, 2 rated 2 of 5.
  • CMS gives this hospital no overall star rating to compare.
Source:

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for hospitals, so none are shown. The one payment cut CMS publishes for each hospital, under its Hospital-Acquired Condition Reduction Program, is shown where it applies.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • Most hospitals are accredited by a private organisation (The Joint Commission, DNV and others) whose routine inspections stand in for the state’s; those reports aren’t public, and QCOR holds only the state’s surveys: no inspection on record here doesn’t mean none took place.
  • QCOR says its hospital inspection data are complete only through September 17, 2026, while it moves to a new system.
  • CMS doesn’t publish staffing levels for hospitals.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Nov 5, 2026.

From the hospital

The public record above comes first. Anything the hospital adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the hospital will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the hospital”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.