Unity Hospital of Rochester - St. Mary’s
A dialysis facility in Rochester, New York 14611
89 Genesee Street, St. Mary’s Campus Dialysis, Rochester, New York 14611. (585) 368-3934.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 1of 5 CMS’s star rating
- Not rated patient survey rating
- 5 deficiencies cited in the last three years
- 21 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Aug 6, 2025: a standard inspection.
5 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
5 deficiencies in 1 month of the last 36. Last cited Aug 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Aug 6, 2025: standard inspection5 deficiencies
-
Ic - Wear Gowns, Shields/Masks; Staff Not Eat/Drink In Tx Area
The inspectors’ words, 650 words
“IC-GOWNS, SHIELDS/MASKS-NO STAFF EAT/DRINK CFR(s): 494.30(a)(1)(i) Staff members should wear gowns, face shields, eye wear, or masks to protect themselves and prevent soiling of clothing when performing procedures during which spurting or spattering of blood might occur (e.g., during initiation and termination of dialysis, cleaning of dialyzers, and centrifugation of blood). Staff members should not eat, drink, or smoke in the dialysis treatment area or in the laboratory. This Standard is not met as evidenced by: 40430 Based on policy review, observation, and interview, the facility does not ensure staff wear personal protective equipment (PPE-equipment worn for protection from workplace hazards such as blood) when cleaning/disinfecting patient care supplies/equipment and performing procedures which spurting or splattering of blood may occur. Findings include: Review of policy “Cleaning Reusable Equipment and Management of Multi-use Supplies Policy,” effective April 2024, indicated staff must wear PPE at all times while cleaning any reusable equipment. Review of the policy “Fresenius 2008 Dialysis Machine: Preparation and Setup Policy,” effective October 2024, indicated PPE equipment including clean gloves, gown and eye protection is required. If staff member has left machine during prime mode, they must wash hands and don (put on) clean gloves before returning to the machine. Review of the policy “Dialysis Infection Prevention Protocols (Supplemental) Policy,” effective March 2025, indicated personnel must wear disposable gloves for all patient and machine contact. Face protection (fluid barrier mask, goggles, shield, etc.) and an impervious (fluid resistant) gown must be worn by personnel while handling blood access, initiating or discontinuing treatment and dismantling equipment or whenever risk of blood contamination is evident. PPE is to be worn while performing procedures during which spurting or spattering of blood might occur. All personnel must scrupulously practice hand washing. Hand hygiene must be performed upon entering and exiting patient station, after all patient contact, when removing gloves and whenever hands are soiled. Observation on 08/04/25 at 10:20 AM at Station #22 revealed Staff (V), Patient Care Technician, was setting up/preparing a hemodialysis machine for the next scheduled patient. Staff (V) was wearing a short sleeve blue PPE gown, that did not cover their arms to their wrists, exposing their personal scrub jacket and was not wearing gloves while touching the machine and dialysis lines/set up with their bare hands. When the hemodialysis machine was priming, Staff (V) exited the station. At 10:30 AM Staff (V) returned to Station #19, did not don gloves, and used their bare hands to connect the dialysis lines together and touch the dialysis machine screen/buttons. At 12:20 PM at Station #15 for Patient #6, revealed Staff (O), Licensed Practical Nurse, initiating hemodialysis treatment via a central venous catheter (CVC-tube inserted into a large vein in the body to provide access for dialysis) wearing a short sleeve blue PPE gown, that did not cover their arms to their wrists, exposing their bare arms. At 03:40 PM at Station #22 for Patient #21, Staff (V) rinsed/returned blood to Patient #21 at the end of their hemodialysis treatment wearing a short sleeve blue PPE gown. At 03:50 PM at Station #13 for Patient 22, Staff (O) cannulated (put needles in) and initiated treatment wearing a short sleeve blue PPE gown. Observation on 08/05/25 at 09:30 AM revealed Staff (V), Patient Care Technician, wore gloves while typing on the computer keyboard (computer workstation on wheels) in front of Station #5. Staff (V) entered Station #5, wearing the same gloves and not wearing a PPE gown, to “tear down” and/or to remove the dirty/used dialysis blood lines from the hemodialysis machine. Staff (V) removed their gloves but did not perform hand hygiene prior to exiting the station. At 10:05 AM at Station #13, revealed Staff (Y), Registered Nurse, did not wear eye protection/goggles while “tearing down” and/or removing the dirty/used dialysis blood lines from the hemodialysis machine. Interview on 08/06/25 at 01:45 PM with Staff (F), Facility Administration, verified these findings.”
-
Ic - Supply Cart Distant/No Supplies In Pockets
The inspectors’ words, 323 words
“IC-SUPPLY CART DISTANT/NO SUPPLIES IN POCKETS CFR(s): 494.30(a)(1)(i) If a common supply cart is used to store clean supplies in the patient treatment area, this cart should remain in a designated area at a sufficient distance from patient stations to avoid contamination with blood. Such carts should not be moved between stations to distribute supplies. Do not carry medication vials, syringes, alcohol swabs or supplies in pockets. This Standard is not met as evidenced by: 40430 Based on policy review, observation, and interview, the facility did not ensure patient care supplies were stored in a manner to avoid contamination. Specifically, gloves are being placed in staff uniform pockets. Findings include: Review of the policy “Cleaning Reusable Equipment and Management of Multi-use Supplies Policy,” effective April 2024, indicated any supplies brought into the patient station that cannot be disinfected must be discarded. The policy did not include direction on storing patient care supplies in uniform pockets. Review of the policy “Dialysis Infection Prevention Protocols (Supplemental) Policy,” effective March 2025, indicated all personnel must scrupulously practice hand washing. Hand hygiene must be performed upon entering and exiting patient station, after all patient contact, when removing gloves and whenever hands are soiled. Observation on 08/04/25 at 10:40 AM at Station #21 revealed Staff (Q), Registered Nurse, was initiating treatment for Patient #20 via their central venous catheter (CVC-tube inserted into a large vein in the body to provide access for dialysis). After connecting the dialysis tubing to the catheter ports, Staff (Q) removed their gloves and without performing hand hygiene and exited the station to the retrieve several clean gloves from the box on the common supply cart, placing the gloves in their uniform pocket. Staff (Q) entered Station #21 and without performing hand hygiene, donned (put on) gloves that they took out of their uniform pocket, and touched the hemodialysis machine. Interview on 08/06/25 at 01:45 PM with Staff (F), Facility Administration, verified these findings.”
-
Ic - Staff Education Re Catheters/Catheter Care
The inspectors’ words, 642 words
“IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 40430 Based on policy review, observation, and interview, the facility did not ensure nursing staff maintained aseptic (steps taken to prevent the spread of infection) technique when performing central venous catheter care (CVC-tube inserted into a large vein above the heart to provide access for dialysis). Findings include: Review of the policy “Initiation and Termination of Dialysis with a Hemodialysis Catheter Policy,” effective April 2024, indicated to make sure the patient is masked. After treatment is complete and blood is returned to the patient, check blood pressure and ask them how they feel. Once post-treatment vital signs are stable and assessment is complete, perform hand hygiene, and don (put on) clean gloves. Review of “Hemodialysis Catheter Dressing Change Policy,” effective August 2024, indicated to place a mask on patient. Remove the old dressing and discard. Remove gloves, perform hand hygiene, and don clean gloves. Review of the policy “Dialysis Infection Prevention Protocols (Supplemental) Policy,” effective March 2025, indicated all personnel must scrupulously practice hand washing. Hand hygiene must be performed upon entering and exiting patient station, after all patient contact, when removing gloves and whenever hands are soiled. Observation on 08/04/25 at 10:20 AM at Station #9 for Patient #19, revealed Staff (U), Licensed Practical Nurse, initiated treatment via a central venous catheter (CVC- tube inserted into a large vein in the body to provide access for dialysis). Patient #19’s face mask was below their nose with their nostrils exposed. At 10:40 AM at Station #21 Staff (Q), Registered Nurse, was setting up to initiate treatment for Patient #20 via a CVC access. Staff (Q) removed their gloves, did not perform hand hygiene, and exited the station to the common supply cart to retrieve a mask for the patient. Staff (Q) re-entered the station and donned clean gloves without performing hand hygiene. After connecting the dialysis tubing to the CVC ports, Staff (Q) removed the old CVC dressing, removed their gloves, but did not perform hand hygiene prior to donning a new clean pair of gloves to cleanse the CVC exit site (site where the catheter enters the body). Staff (Q) removed their gloves, did not perform hand hygiene, reached down the neck hole of their PPE gown to retrieve their pen from the breast pocket of their uniform to label the new CVC dressing. Staff (Q) put the pen back in their breast pocket. Staff (Q) donned a new pair of gloves without performing hand hygiene and proceeded to apply a new dressing to the CVC exit site. Observation on 08/05/25 at 10:00 AM at Station #13 revealed Staff (O), Licensed Practical Nurse, discontinued treatment for Patient #12. After checking the sitting and standing blood pressure, Staff (O) removed their gloves, but did not perform hand hygiene prior to donning clean gloves to cleansing the CVC ports and disconnecting the dialysis tubing/blood lines. Interview on 08/06/25 at 01:45 PM with Staff (F), Facility Administrator, and 02:15 PM with Staff (I), Facility Administrator, verified these findings.”
-
Carbon Adsorption - Monitoring, Testing Frequency
The inspectors’ words, 412 words
“CARBON ADSORP-MONITOR, TEST FREQUENCY CFR(s): 494.40(a) 6.2.5 Carbon adsorption: monitoring, testing freq Testing for free chlorine, chloramine, or total chlorine should be performed at the beginning of each treatment day prior to patients initiating treatment and again prior to the beginning of each patient shift. If there are no set patient shifts, testing should be performed approximately every 4 hours. Results of monitoring of free chlorine, chloramine, or total chlorine should be recorded in a log sheet. Testing for free chlorine, chloramine, or total chlorine can be accomplished using the N.N-diethyl-p-phenylene-diamine (DPD) based test kits or dip-and-read test strips. On-line monitors can be used to measure chloramine concentrations. Whichever test system is used, it must have sufficient sensitivity and specificity to resolve the maximum levels described in [AAMI] 4.1.1 (Table 1) [which is a maximum level of 0.1 mg/L]. Samples should be drawn when the system has been operating for at least 15 minutes. The analysis should be performed on-site, since chloramine levels will decrease if the sample is not assayed promptly. This Standard is not met as evidenced by: 42572 Based on policy review, observation, and interview, the facility does not ensure the reverse osmosis system (RO-a water purification system to make the water safe for patient treatment) is running for 15 minutes before obtaining a water sample for chlorine and chloramines testing (used to disinfect water, harmful to patients). Findings include: Review of the policy “Dialysis - Chloramine Testing of Pre-Treated Water ... Dialysis Locations Procedure,” revised June 2025, indicated the water is to be tested every four hours and the RO must run for 15 minutes before every test. Observation on 08/05/25 at 02:10 PM in the water room, revealed that the RO system only runs when the water holding tank is being filled. Interview on 08/05/25 at 02:05 PM with Staff (P), Patient Care Technician, revealed they performed a total chlorine test on the RO system but did not know how to verify if the RO system was continuously running for at least 15 minutes prior to the testing. Interview on 08/05/25 at 02:10 PM with Staff (E), Biomedical Technician, verified that Staff (P), Patient Care Technician, did not know how to determine if the RO was running for 15 minutes prior to performing water testing for Chlorine/Chloramines. Staff (E) verified the RO system does not run for at least 15 minutes prior to each water test and only runs when the water holding tank is being filled.”
-
Pe - Building - Constructed/Maintained To Ensure Safety
The inspectors’ words, 239 words
“PE-BUILDING-CONSTRUCT/MAINTAIN FOR SAFETY CFR(s): 494.60(a) The building in which dialysis services are furnished must be constructed and maintained to ensure the safety of the patients, the staff and the public. This Standard is not met as evidenced by: 42572 Based on observation and interview, the building is not maintained, free from defects and/or hazards to ensure safety and functionality for patients, staff, and visitors. Findings include: Observation on 08/04/25 at 10:45 AM in the treatment area adjacent to the double doors, revealed a four-tier, steel wire shelf, used for the storage of gallon acid solution jugs used during the hemodialysis treatment. There were two areas at the front of the bottom two shelves, approximately four-inches square, that were rusty with a brown rusty colored precipitate (possible spill) spanning between the wires of the shelves. The rust has the potential to prevent proper disinfection when cleaning the surface. Observation on 08/04/25 at 11:45 AM in the water room, revealed two holes in the vinyl flooring. The first hole was approximately a six-inch long tear in the flooring behind the acid mixing tank where the flooring meets/extends up the wall. The second hole was an approximately three-inch by nine-inch hole in the flooring next to the floor drain in the middle of the room. Water under the flooring in these areas creates the potential for mold growth. Interview on 08/04/25 at 12:00 PM with Staff (E), Biomedical Technician, verified these findings.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Aug 6, 2025 | Standard inspection | 5 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Jan 1, 2011.
- Run as a non-profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis and a shift starting at 5 p.m. or later.
- Doesn’t offer peritoneal dialysis and home hemodialysis training.
- 21 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- CMS lists it as independent, not owned or managed by a chain.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 1 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, worse than expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 1 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 14 dialysis facilities CMS lists in Monroe County, 13 have a star rating from CMS: 7 rated 2 of 5, 6 rated 1 of 5.
- CMS rates this one 1 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.