Hearth Record

Usrc Williamsville Dialysis

A dialysis facility in Williamsville, New York 14221

7964 Transit Road, Suite 8-A, Williamsville, New York 14221. (716) 634-1841.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 8 deficiencies in 1 month of the last 36. Last cited Mar 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Mar 29, 2024: a standard inspection.

8 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

8 deficiencies in 1 month of the last 36. Last cited Mar 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

8 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Mar 29, 2024: standard inspection8 deficiencies
  • Ic - Clean/Dirty Areas, Med Prep Area, No Common Med Carts

    The inspectors’ words, 262 words

    “IC-CLEAN/DIRTY;MED PREP AREA;NO COMMON CARTS CFR(s): 494.30(a)(1)(i) Clean areas should be clearly designated for the preparation, handling and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or an adjacent area to that where used equipment or blood samples are handled. When multiple dose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multiple dose medication vials from station to station. Do not use common medication carts to deliver medications to patients. If trays are used to deliver medications to individual patients, they must be cleaned between patients. This Standard is not met as evidenced by: 32261 Based on observation, policy review, and interview, nursing staff do not ensure patient medications are secured. This has the potential for unauthorized access/tampering of patient medications. Findings include: Observation on 03/28/24 at 09:40 AM on the treatment floor revealed pre-draw heparin filled syringes labeled for Patient #17, #21, #22, and #23 that were placed on the back nursing station counter. The syringes were unsecured and not under the custody of staff. Review on 03/29/24 of the policy “Guidelines for Administration of medication,” last revised 02/2024 revealed medications will be locked in a cabinet or a medication fridge. Interview on 03/29/24 at 11:15 AM with Staff (A), Facility Administrator, and Staff (F), Area Clinical Coordinator, confirmed these findings.”

    Rule V0117. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 413 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 32261 Based on observation, policy review, and interview, staff do not clean and disinfect all contaminated surfaces at patient stations (Station #1, #2, #3, #4, #5, #6, #7, #8, #9, #10, #11 and #12). This lapse in disinfection places staff and patients at risk for the transmission of bloodborne pathogens and facility acquired infections. Findings include: Observation on 03/27/24 at 02:00 PM in the patient care unit at Station #11 revealed Staff (K), Patient Care Technician, and Staff (G), Licensed Practical Nurse, discontinued treatment for fistula Patient #12. They did not disinfect the sharps container or the biohazard waste bin that were brought into Station #11, prior to placing the container and bin back in a common area. At 02:25 PM at Station #5, Staff (G), Licensed Practical Nurse, initiated treatment for catheter Patient #8, but did not disinfect biohazard waste bin brought into Station #5, prior to placing the bin back in the common area. On 03/28/24 at 09:50 AM at Station #6, Staff (M), Registered Nurse, initiated treatment for catheter Patient #19, but did not disinfect biohazard waste bin brought into Station #6, prior to placing the bin back in the common area. Observation on 03/27/24 from 11:00 AM to 02:20 PM and on 03/28/23 from 09:00 AM to 12:30 PM in the patient care unit revealed that staff did not disinfect the garbage cans in Stations #1-#12 after each patient treatment. Review on 03/28/24 of the policy “Guidelines for Handling and Disposal of Infectious Medical Waste,” last revised 04/2023 revealed biohazard containers will be brought to the point of use (example: near chairside) to dispose of biohazard waste. (The policy does not include the need to disinfect the bins prior to returning to a common/storage area) Review on 03/28/24 of the policy “Disinfection and Cleaning of Dialysis Machine Equipment,” last revised 07/2023 revealed the disinfection procedure for cleaning/disinfecting the dialysis machine, the back counter, and the dialysis chair. (The policy does not include to disinfect garbage cans located in patient stations, between patient treatments). Interview on 03/29/24 at 11:15 AM with Staff (A), Facility Administrator, and Staff (F), Area Clinical Coordinator, confirmed these findings.”

    Rule V0122. Standard-level.

  • Ic - Staff Education Re Catheters/Catheter Care

    The inspectors’ words, 320 words

    “IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 32261 Based on policy review, medical record review, and interview, the facility does not ensure a registered nurse assesses the central venous catheter insertion site each hemodialysis treatment for three of three central venous catheter hemodialysis patients (Patients #8, #9 and #11). Lack of assessment has the potential to delay identification and treatment of a potential catheter infection or issue. Findings include: Review on 03/28/24 of policy “Dialysis Catheter Dressing Change Procedure” last revised 02/2023 revealed that the care of catheters will include an accurate assessment of the insertion site for signs/symptoms of infection and documentation of observations. Review on 03/28/24 of the treatment flowsheets for catheter Patient #8 on 03/11/24, 03/13/24, 03/18/24, 03/20/24, 03/22/24, and 03/25/24; Patient #9 on 03/08/24, 03/09/24, 03/15/24, 03/16/24, 03/18/24, 03/20/24, 03/22/24, 03/25/24, and 03/27/24; and Patient #11 on 12/12/23, 12/14/23, 12/16/23, 12/19/23, 01/20/24, 03/07/24, and 03/12/24 revealed no documentation that a registered nurse assessed the catheter insertion site. Interview on 03/29/24 at 11:15 AM with Staff (A), Facility Administrator, and Staff (F), Area Clinical Coordinator, verified these findings.”

    Rule V0147. Standard-level.

  • Softeners - Testing Hardness/Log

    The inspectors’ words, 196 words

    “SOFTENERS: TESTING HARDNESS/LOG CFR(s): 494.40(a) 6.2.4 Softeners: Testing hardness/log Users should ensure that test accuracy and sensitivity are sufficient to satisfy the total hardness monitoring requirements of the reverse osmosis machine manufacturer. Total hardness of the water exiting the water softener should be measured at the end of each treatment day. Water hardness test results should be recorded in a water softener log. This Standard is not met as evidenced by: 16136 Based on document review and interview, the facility does not ensure that the water hardness is tested at the end of each treatment day. Findings include: Review on 03/28/24 of the document “Water Treatment Log PM,” dated 12/2023, 01/2024, 02/2024, and 03/2024 revealed that the water hardness testing was not performed after the last dialysis patient had ended treatment. Staff tested the water hardness prior to 07:00 PM 15 of 27 days in December 2023, 18 of 26 days in January 2024, 14 of 25 days in February 2024, and 12 of 22 days in March 2024. Interview on 03/28/24 at 10:30 AM with Staff (A), Facility Administrator, and Staff (F), Area Clinical Coordinator, indicated that the last patient treatment ends at 07:00 PM.”

    Rule V0191. Standard-level.

  • Carbon Adsorption - 10 Minutes Ebct

    The inspectors’ words, 269 words

    “CARBON ADSORPTION-10 MINUTES EBCT CFR(s): 494.40(a) 5.2.5 Carbon adsorption: 10 min EBCT Refer to RD62:2001, 4.3.9 Carbon adsorption media: When granulated activated carbon is used as the adsorption medium ... each adsorption bed shall have an [empty bed contact time] EBCT of at least 5 minutes at the maximum product water flow rate (a total EBCT of at least 10 minutes). This Standard is not met as evidenced by: 16136 Based on observation, document review, and interview, the facility does not ensure that the carbon tank has an absorption empty bed contact time (EBCT- the amount of time water is in contact with the activated carbon in the tank) of at least five minutes at the maximum product water flow rate for a total empty bed contact time of 10 minutes. Failure to ensure the proper empty bed contact time is obtained may result in unsafe water being supplied to the dialysis patients. Findings include: Observation on 03/28/24 at 11:13 AM in the water room revealed that two carbon tanks were present. Each tank consisted of 5.5 cubic feet of carbon, providing for a total of 11 cubic feet of carbon. Review on 03/28/24 of the document “Daily Water Log AM,” revealed the water processed through the reverse osmosis unit (water filtration system) was nine gallons per minute. The total empty bed contact time was 9.1 minutes at the product water flow rate and did not reach the required total empty bed contact time of 10 minutes on 12/08/23, 12/14/23, 01/10/24, 01/30/24, and on 02/03/24. Interview on 03/28/24 at 10:40 AM with Staff (Q), Biomed Technician, verified this finding.”

    Rule V0195. Standard-level.

  • Mixing Sys - Follow Dfu/Monitor/Pm/Log/Sanitization

    The inspectors’ words, 296 words

    “MIX SYS-DFU/MONITOR/PM/LOG/SANITIZE CFR(s): 494.40(a) 5.4.4.1 Mixing systems: follow DFU/monitor/PM/log/sanitization If a concentrate mixing system is used, the preparer should follow the manufacturer’s instructions for mixing the powder with the correct amount of water. If a concentrate mixing system is used, the number of bags or the weight of powder added should be determined and recorded. Manufacturer’s recommendations should be followed regarding any preventive maintenance and sanitization procedures. Records should be maintained indicating the date, time, person performing the procedure, and results (if applicable). 6.4.1 Mixing systems: Systems for preparing either bicarbonate or acid concentrate from powder should be monitored according to the manufacturer’s instructions. This Standard is not met as evidenced by: 16136 Based on policy review, document review, and interview, the facility does not ensure that the filter on the acid mixing system is changed after six batches of acid solution has been prepared or that a rinse cycle has been performed before mixing another batch of acid solution. Findings include: Review on 03/28/24 of the policy “Dry Acid Mixing-Granuflo- #TM 03-05,” last revised 08/2021, indicated that the manufacturer’s recommendation is to change the filter after mixing six batches of acid solution and to perform a rinse cycle before mixing each batch of dry acid. Review on 03/28/24 of the document “Dry Acid Mixing-132 Gallon log,” dated from 11/03/23 to 02/03/24 revealed that the filter had been replaced on 11/03/23 and not again until 02/03/24, after the preparation of 19 batches of acid solution. No documentation was found to indicate the filter is changed after the preparation of six batches of acid and/or that the acid tank was rinsed prior to the mixing of the next new batch of acid solution. Interview on 03/28/24 at 04:30 PM with Staff (Q), Biomed Technician, verified these findings.”

    Rule V0226. Standard-level.

  • Dialysate Proportioning - Monitor Ph/Conductivity

    The inspectors’ words, 186 words

    “DIALYS PROPORT-MONITOR PH/CONDUCTIVITY CFR(s): 494.40(a) 5.6 Dialysate proportioning: monitor pH/conductivity It is necessary for the operator to follow the manufacturer’s instructions regarding dialysate conductivity and to measure approximate pH with an independent method before starting the treatment of the next patient. This Standard is not met as evidenced by: 16136 Based on policy review, document review, and interview, the facility does not ensure that an extended calibration is performed monthly on 3 of 3 Phoenix XL meters (meters #1, #2 and #3). Findings include: Review on 03/29/24 of the policy “Phoenix-Phoenix XL, Meter Cleaning and Calibration,” last revised 08/2020, indicated that the biomedical technician will perform extended range calibrations monthly. Review on 03/29/24 of the document “Monthly Phoenix XL Meter Logs,” April 2023 to March revealed that an extended monthly calibration was not performed for meters #1 and #2 in 05/2023, 07/2023, 08/2023 and 10/2023. Review on 03/29/24 of the document “Phoenix XL Meter AM Log” from 01/2024 through 03/2024 revealed that an extended calibration had not been performed for meter #3. Interview on 03/29/24 at 01:20 PM with Staff (Q), Biomed Technician, verified these findings.”

    Rule V0250. Standard-level.

  • Staff Licensed As Req/Qualified/Demonstrate Competencies

    The inspectors’ words, 383 words

    “PQ-STAFF LIC AS REQ/QUAL/DEMO COMPETENCY CFR(s): 494.140 All dialysis facility staff must meet the applicable scope of practice board and licensure requirements in effect in the State in which they are employed. The dialysis facility’s staff (employee or contractor) must meet the personnel qualifications and demonstrated competencies necessary to serve collectively the comprehensive needs of the patients. The dialysis facility’s staff must have the ability to demonstrate and sustain the skills needed to perform the specific duties of their positions. This Standard is not met as evidenced by: 32261 Based on policy review, medical record review, and interview, staff do not act within their scope of practice. Specifically, licensed practical nurses and patient care technicians did not notify the registered nurse regarding changes in a patient’s condition and/or treatment prescription for two of four patients (Patient #10 and #11). Lack of notification can delay assessment, treatment, and has the potential for an adverse patient outcome. Findings include: Review on 03/28/24 of policy “Reportable Parameters to Charge Nurse,” last revised 01/2020 revealed that intra-dialysis issues to be reported to the charge nurse include, but not limited to, a systolic blood pressure reading of less than 90 and poor blood flows. Review on 03/28/24 of the treatment flowsheet for Patient #10 (has a fistula access) dated 03/04/24 revealed that Staff (I), Patient Care Technician, decreased the blood flow rate to 250 and did not notify the registered nurse. The ordered blood flow rate was 450. Review on 03/28/24 of the treatment flowsheets for Patient #11 (has a catheter access) dated 12/16/23 revealed Staff (R), Patient Care Technician decreased the blood flow rate to 400. On 12/19/23, Staff (P), Licensed Practical Nurse, decreased the blood flow rate to 400. On 02/01/24, Staff (S), Patient Care Technician, decreased the blood flow rate to 250. There was no evidence the registered nurse was notified. The ordered blood flow rate was 450. Review on 03/28/24 of the treatment flowsheets for Patient #11 (has a catheter access) dated 01/30/24 revealed that Staff (G), Licensed Practical Nurse, administered 200 milliliters of normal saline due to a low blood pressure reading of 86/47. There was no evidence the registered nurse was notified. Interview on 03/29/24 at 11:15 AM with Staff (A), Facility Administrator, and Staff (F), Area Clinical Coordinator, verified these findings.”

    Rule V0681. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Mar 29, 2024Standard inspection8 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Jan 20, 2012.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: US Renal Care, Inc.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 13 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the US Renal Care, Inc. chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 3 of 5 in CMS’s survey of in-center hemodialysis patients (31 interviews, Oct 18, 2024 to Jul 11, 2025): 61% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 53 of 5

How does it compare nearby?

  • Of the 17 dialysis facilities CMS lists in Erie County, 15 have a star rating from CMS: 3 rated 4 of 5, 5 rated 3 of 5, 5 rated 2 of 5, 2 rated 1 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.