Hearth Record

Usrc Cheektowaga Dialysis

A dialysis facility in Cheektowaga, New York 14227

2875 Union Road, Suite 13 C/D, Cheektowaga, New York 14227. (716) 684-0276.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 7 deficiencies in 1 month of the last 36. Last cited Mar 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Mar 19, 2025: a standard inspection.

7 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

7 deficiencies in 1 month of the last 36. Last cited Mar 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

7 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Mar 19, 2025: standard inspection7 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 334 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 40430 Based on policy review, observation, and interview, nursing staff do not follow standard infection control practices regarding the use of gloves and hand hygiene. Specifically, staff do not change gloves and/or perform hand hygiene when entering/exiting the dialysis station, when performing safety checks/touching the machine, and when using the computer keyboard while monitoring patients during their dialysis treatment. Findings Include: Review of the policy “Infection Control and Precautions for All Patients,” revised July 2023, indicated staff will perform hand hygiene using soap and water or antibacterial hand sanitizer before/after all patient contact and before applying and removing gloves. Hand hygiene must be performed after contact with the integrated keyboard or chairside computer, regardless of whether contact occurred through gloved or ungloved hands. Staff must remove gloves and perform hand hygiene between each patient or station. Observation on 03/17/25 at 02:38 PM at Station #2 for Patient #17 revealed Staff (K), Registered Nurse, touched the dialysis machine screen and computer keyboard with gloved hands. Without removing gloves and performing hand hygiene, Staff (K) exited Station #2 leaving their gloves on. Staff (K) entered Station #5 for Patient #21, wearing the same gloves, touched the dialysis machine screen to reset an alarm, and type on the computer keyboard. At 2:39 PM, wearing the same gloves, Staff (K) exited Station #5, entered Station #6 for Patient #22, and touched the dialysis machine screen and computer keyboard. At 2:40 PM, wearing the same gloves, Staff (K) exited Station #6, entered Station #8 for Patient #2, and touched the dialysis machine screen and computer keyboard. Staff (K) exited Station #8, removed their gloves, and performed hand hygiene. Interview on 03/19/25 at 01:45 PM with Staff (B), Nurse Manager and Staff (O), Clinical Specialist, verified these findings.”

    Rule V0113. Standard-level.

  • Ic - Handling Infectious Waste

    The inspectors’ words, 379 words

    “IC-HANDLING INFECTIOUS WASTE CFR(s): 494.30(a)(4)(i) [The facility must demonstrate that it follows standard infection control precautions by implementing-] (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the- (i) Handling, storage and disposal of potentially infectious waste; This Standard is not met as evidenced by: 34528 Based on policy review, observation, and interview, the facility does not ensure appropriate disposal of needles and sharps into sharps containers (puncture/leak resistant container) and that the sharps containers are secure to prevent tipping and/or spillage of contents. Findings Include: Review of the policy “Preparation and Administration of IV/Sub Q/IM Medications,” revised February 2023, indicated after drawing up the correct amount of medication from the vial, discard the vial in the appropriate container. Review of the policy “Guidelines for the Handling and Disposal of Infectious Medical Waste,” revised April 2023 indicated contaminated sharps including blades, needles, vacutainers and syringes are considered and treated as infectious and/or special waste materials. Special waste requires special handling and disposal to protect human health or the environment. All needles and sharps will be placed in puncture resistant containers. (The policy did not indicate sharps containers need to be secure to prevent tipping and/or spillage of contents). Observation on 03/17/25 and 03/18/25 from 08:30 AM to 03:40 PM and 03/19/25 from 08:30 AM to 12:00 PM, in the medication storage/preparation area, revealed an empty 10 x 6 x 6-inch cardboard box located on the medication area countertop. There were 10-20 used/empty glass medication vials and one capped one ml syringe (on 03/17/25), no longer in its packaging. Interview on 03/19/25 at 08:40 AM Staff (H), Licensed Practical Nurse, verified this finding and stated the facility does not have a small sharps container for the medication storage/preparation area. The cardboard box was used for sharps disposal. Staff empty the box into a secured sharps container at the end of each night. Observation on 03/19/25 at 01:03 PM in peritoneal dialysis (PD) training area revealed three training rooms that had a sharps container located on the floor, not secured to prevent tipping and/or spillage. Interview 03/19/25 at 01:15 PM with Staff (F), Home Hemodialysis/PD Nurse, and 01:45 PM with Staff (B), Nurse Manager and Staff (O), Clinical Specialist, verified these findings.”

    Rule V0121. Standard-level.

  • Ic - Staff Education Re Catheters/Catheter Care

    The inspectors’ words, 439 words

    “IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 40430 Based on policy review, observation, and interview, in four of four patients observed, nursing staff do not use the appropriate infection control measures to prevent infections for central venous catheters (CVC-tube inserted into a large vein in the body to provide access for dialysis). Specifically, staff do not replace the pad under the catheter with a new, clean pad at the completion of the dialysis treatments, prior to disconnecting the blood lines from the CVC ports (Patient #4, Patient #17, Patient #18, and Patient #19). Findings Include: Review of the policy “Accessing and De-Accessing the Dialysis Catheter,” revised June 2024, indicated staff are to replace the under pad beneath the CVC in preparation to disconnect the patient from the blood lines at the completion of their dialysis treatment. Observation on 03/17/25 at 02:24 PM at Station #12 for Patient #4 and at 03:00 PM at Station #2 for Patient #17 revealed Staff (H), Licensed Practical Nurse, did not replace the pad under the CVC with a clean pad at the completion of the dialysis treatments, prior to disconnecting the blood lines from the CVC ports. Observation on 03/18/25 at 10:45 AM at Station #1 for Patient #18 revealed Staff (N), Registered Nurse, did not replace the pad under the CVC with a clean pad at the completion of the dialysis treatments, prior to disconnecting the blood lines from the CVC ports. At 02:35 PM at Station #12 for Patient #19, Staff (M), Registered Nurse, did not replace the pad under the CVC with a clean pad at the completion of the dialysis treatments, prior to disconnecting the blood lines from the CVC ports. Interview on 03/19/25 at 01:45 PM with Staff (B), Nurse Manager, and Staff (O), Clinical Specialist, verified these findings.”

    Rule V0147. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 164 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 25545 Based on observation and interview, the facility does not maintain two of two eye washes with tepid water. Findings Include: Observation on 03/18/25 at 11:00 AM revealed that the eye wash station on the treatment floor and the eye wash station in the storage area were plumbed to cold water only. The temperature was measured at both eye wash stations at 41.7 degrees Fahrenheit. According to the American National Standard Institute Z358.1 2014: Emergency Eyewash & Shower Standard (for Emergency Eyewash and Shower Equipment), eyewash stations require tepid water as defined as 60 degrees Fahrenheit (F) to 100 degrees F. Interview on 03/18/25 at 11:00 AM with Staff (E), Biomedical Technician, verified these findings.”

    Rule V0403. Standard-level.

  • Pe-Fire Safety-Life Safety Code

    The inspectors’ words, 235 words

    “PE-FIRE SAFETY-LIFE SAFETY CODE CFR(s): 494.60(e)(1) (1) Except as provided in paragraph (d)(2) of this section, dialysis facilities that do not provide one or more exits to the outside at grade level from the patient treatment area level must comply with provisions of the Life Safety Code (NFPA 101 and its Tentative Interim Amendments TIA 12-1, TIA 12-2, TIA 12-3, and TIA 12-4) applicable to Ambulatory Health Care Occupancies, regardless of the number of patients served. This Standard is not met as evidenced by: 25545 Based on document review and interview, the facility does not document required parameters while the generator (source of emergency power) was running with a load (the electrical demand placed on a generator). Findings Include: Review on 03/19/25 of the “Monthly Generator Log,” dated 01/12/25, 02/09/25, and 03/16/25, revealed the generator was tested under a load. However, neither amps (the unit of measurement for an electrical current, which is the flow of electric current through a conductor) drawn by the load, or the water temperature and oil pressure were not documented. Interview on 03/19/2025 at 10:00 AM with Staff (E), Biomedical Technician, revealed they conducts the monthly generator test with a load, but they did not document either amps, or water temperature and oil pressure according to NFPA 110 Standards for Emergency and Standby Power Systems 2010 edition, which is a referenced publication of NFPA 101 Life Safety Code 2012 edition.”

    Rule V0417. Standard-level.

  • Appropriateness Of Dialysis Rx

    The inspectors’ words, 672 words

    “PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 40430 Based on policy review, observation, medical record review, and interview, for six of eight patients/medical records reviewed, the registered nurse does not ensure the hemodialysis prescription is implemented and/or maintained for the ultrafiltration profile (UF-amount of fluid removed in a specified time. Profiles allow for the fluid removal at various intervals vs. removing the same amount throughout a treatment), dialysate flow rates (DFR-rate dialysate flows through a dialyzer or artificial kidney, to remove toxins from a patient’s bloodstream), blood flow rates (BFR- rate at which blood is processed during dialysis), and the correct dialyzer (filter used to clean blood) for (Patient # 2, Patient #11, Patient #12, Patient #14, Patient #26, and Patient #27). Findings Include: Review of the policy “Pre-Treatment Assessment of Patient,” revised January 2020, indicated patients will receive hemodialysis treatment and nursing care based on data collected and pre dialysis nursing assessment. The pre-dialysis nursing assessment will occur within the first hour of patient contact or per stricter state regulations. Review of the policy “Initiation of Dialysis Treatment,” revised July 2024, indicated two staff members must verify and document the correct prescription on the treatment flowsheet. Prior to walking away from the patient’s dialysis machine, verify that all prescribed orders are followed. If unable to follow any part of the patient’s prescription, notify the charge nurse and document the notification. Prescription orders and safety measures include verification the dialyzer, DFR, BFR, and fluid removal (UF) goal are programmed correctly. Observation and medical record review on 03/18/25 from 11:25 AM to 12:06 PM revealed the following: - For Patient #11 at Station #5: The hemodialysis machine had an Optiflux 180 dialyzer (filter brand/size) dialyzer in use. The medical record flow sheet indicated the ordered dialyzer was an Optiflux 160 dialyzer. There was no documentation found in the medical record to indicate why a different size dialyzer was utilized. - For Patient #12 at Station #4: The hemodialysis machine was set with a DFR of 500 milliliters per minute (ml/min). The medical record flow sheet indicated the prescribed/ordered DFR was 600 ml/min. There was no documentation found in the medical record to indicate why the DFR was not implemented as ordered. Medical record review on 03/18/25 revealed the following: - For Patient #2: Review of the medical record flowsheets from 02/14/25 to 03/17/25 revealed a prescribed/ordered DFR of 800ml/min and BFR of 350ml/min. On 02/14/25, the DFR was set at 500ml/min. On 02/28/25, the BFR was set at 250-300ml/min. There was no documentation found in the medical record to indicate why the DFR and BFR were not implemented as ordered. - For Patient #14: Review of the medical record flowsheets from 02/19/25 to 03/10/25 revealed a prescribed/ordered DFR of 800ml/min. On 03/07/25, the DFR was reduced to 500ml/min. There was no documentation found in the medical record to indicate why the DFR was reduced and not maintained as ordered. - For Patient #26: Review of the medical record flowsheets from 02/24/25 to 03/17/25 revealed a prescribed/ordered UF profile #1 ( profile- instead of a constant rate profiling adjusts rate of fluid removal throughout treatment to reduce complications during dialysis). On 03/07/25, no UF profile was not set/implemented as ordered. There was no documentation found in the medical record to indicate why the UF profile was not implemented as ordered. - For Patient #27: Review of the medical record flowsheets from 02/22/25 to 03/15/25 revealed a prescribed/ordered BFR of 450ml/min and UF profile #3. On 03/04/25 and 03/06/25, the BFR was set at 200-325ml/min. On 03/13/25, the UF profile was not set/implemented as ordered. There was no documentation found in the medical record to indicate why the BFR and UF profile were not implemented as ordered. Interview on 03/19/25 at 01:45 PM with Staff (B), Nurse Manager, and Staff (O), Clinical Specialist, verified these findings.”

    Rule V0503. Standard-level.

  • Staff Licensed As Req/Qualified/Demonstrate Competencies

    The inspectors’ words, 377 words

    “PQ-STAFF LIC AS REQ/QUAL/DEMO COMPETENCY CFR(s): 494.140 All dialysis facility staff must meet the applicable scope of practice board and licensure requirements in effect in the State in which they are employed. The dialysis facility’s staff (employee or contractor) must meet the personnel qualifications and demonstrated competencies necessary to serve collectively the comprehensive needs of the patients. The dialysis facility’s staff must have the ability to demonstrate and sustain the skills needed to perform the specific duties of their positions. This Standard is not met as evidenced by: 40430 Based on policy review, medical record review, and interview, in one of eight medical records reviewed, the licensed practical nurse and/or patient care technician do not notify the registered nurse regarding changes in a patient’s condition (Patient #2). Findings include: Review of the policy “Reportable Parameters to Charge Nurse,” revised January 2020, indicated that intra-dialysis (during dialysis) issues to be reported to the charge nurse are to include a systolic (top value of a blood pressure or “BP” reading that measures the heart pumping rate) blood pressure reading of less than 90. Review on 03/19/25 of the medical record flowsheets for Patient #2, dated from 02/14/25 to 03/17/25, revealed the following: - On 02/17/25 at 01:31 PM, a patient care technician administered 150 milliliters (ml) of NS for a BP of 89/38. There is no documentation in the medical record indicating the registered nurse was notified. - On 02/28/25 at 01:05 PM, a licensed practical nurse administered 200 ml of NS for a BP of 65/36. At 01:09 PM, the licensed practical nurse reduced the ultrafiltration rate (UFR-rate of fluid removal during dialysis). There is no documentation in the medical record indicating the registered nurse was notified. - On 03/07/25 at 01:33 PM, a patient care technician administered 100 ml of NS for a BP of 72/35. There is no documentation in the medical record indicating the registered nurse was notified. - On 03/10/25 at 01:01 PM, a patient care technician administered 100 ml of NS and reduced the UFR for a BP of 89/48. There is no documentation in the medical record indicating the registered nurse was notified. Interview on 03/19/25 at 01:45 PM with Staff (B), Nurse Manager, and Staff (O), Clinical Specialist, verified these findings.”

    Rule V0681. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Mar 19, 2025Standard inspection7 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Dec 16, 2011.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: US Renal Care, Inc.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
  • Doesn’t offer a shift starting at 5 p.m. or later.
  • 13 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 5 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the US Renal Care, Inc. chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, better than expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 5 of 5 in CMS’s survey of in-center hemodialysis patients (33 interviews, Oct 18, 2024 to Jul 11, 2025): 77% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 55 of 5

How does it compare nearby?

  • Of the 17 dialysis facilities CMS lists in Erie County, 15 have a star rating from CMS: 3 rated 4 of 5, 5 rated 3 of 5, 5 rated 2 of 5, 2 rated 1 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.