Davita Mountain Park Dialysis
A dialysis facility in Stone Mountain, Georgia 30083
5235 Memorial Drive, Stone Mountain, Georgia 30083. (404) 296-1344.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 3 deficiencies cited in the last three years (needs attention)
- 16 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean4
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
- Condition-level deficiency
- For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.
What did inspectors find?
The last inspection on record was on Jul 18, 2024: a complaint inspection.
3 deficiencies cited in the last three years, 2 of them at condition level, the most serious.
2 deficiencies at condition level, the more serious of CMS’s two levels
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
3 deficiencies in 1 month of the last 36. Last cited Jul 2024. Most serious: Condition-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jul 18, 2024: complaint inspection3 deficiencies
-
Cfc - Water And Dialysate Quality
The inspectors’ words, 262 words
“CFC-WATER & DIALYSATE QUALITY CFR(s): 494.40 This Condition is not met as evidenced by: 49321 Based on observation, staff interviews, review of Fresenius Medical Care 2008K Hemodialysis Machine Operator’s Manual and a review of facility policy, it was determined that the facility failed to ensure that there was a safe environment for patients as evidenced by failure of three of three Patient Care Technicians (PCT AA, PCT BB, and PCT CC), and one of one Licensed Practical Nurse (LPN AA) to follow the manufacturer’s directions for use and facility’s policy regarding independently testing the machines’ dialysate (a solution of pure water, electrolytes and salts such as bicarbonate and sodium) pH (Acidity) using RPC K100-0117 E-Z Chek 6.8-8.5 pH test strips; and independently testing the conductivity (ability of the dialysate to conduct electricity) using the Myron L D-1 meter. This deficient practice had the potential to negatively affect the health and safety of seven of seven patients (P#2, P#3, P#4, P#7, P#8, P#10, and P#14) observed, during initiation of dialysis treatment. Complications as minor as nausea and fatigue or as severe as metabolic acidosis (decrease in pH that can cause rapid breathing, confusion, dizziness, shortness of breath, chest pain) can result if dialysate composition is incorrect. And if conductivity is off, the effectiveness of the treatment is reduced and patient electrolyte balance can be altered. Findings were: Cross Reference: V 250 - Failure of the facility to independently test the machine’s dialysate pH and conductivity according to the manufacturer’s directions for use and facility’s policy prior to the initiation of each dialysis treatment.”
-
Cfc - Governance
The inspectors’ words, 106 words
“CFC-GOVERNANCE CFR(s): 494.180 This Condition is not met as evidenced by: 49321 Based on observation, staff interviews, and review of records, it was determined that the Governing Body failed to demonstrate responsibility and accountability for the operations of the facility. This failure had the potential to negatively affect the health and safety of 70 in-center hemodialysis patients who were receiving hemodialysis treatment at this facility. Findings include: Cross Reference: V 250 - Failure of the facility to ensure that staff independently tested the machine’s dialysate pH and conductivity according to the manufacturer’s directions for use and facility’s policy, prior to the initiation of each dialysis treatment.”
-
Dialysate Proportioning - Monitor Ph/Conductivity
The inspectors’ words, 850 words
“DIALYS PROPORT-MONITOR PH/CONDUCTIVITY CFR(s): 494.40(a) 5.6 Dialysate proportioning: monitor pH/conductivity It is necessary for the operator to follow the manufacturer’s instructions regarding dialysate conductivity and to measure approximate pH with an independent method before starting the treatment of the next patient. This Standard is not met as evidenced by: 49321 Based on observation, staff interviews, review of Fresenius Medical Care 2008K Hemodialysis Machine Operator’s Manual and a review of facility policy, it was determined that the facility failed to ensure that there was a safe environment for patients as evidenced by failure of three of three Patient Care Technicians (PCT AA, PCT BB, and PCT CC), and one of one Licensed Practical Nurse (LPN AA) to follow the manufacturer’s directions for use and facility’s policy regarding independently testing the machines’ dialysate (a solution of pure water, electrolytes and salts such as bicarbonate and sodium) pH (Acidity) using RPC K100-0117 E-Z Chek 6.8-8.5 pH test strips; and independently testing the conductivity (ability of the dialysate to conduct electricity) using the Myron L D-1 meter. This deficient practice had the potential to negatively affect the health and safety of seven of seven patients (P#2, P#3, P#4, P#7, P#8, P#10, and P#14) observed, during initiation of dialysis treatment. Complications as minor as nausea and fatigue or as severe as metabolic acidosis (decrease in pH that can cause rapid breathing, confusion, dizziness, shortness of breath, chest pain) can result if dialysate composition is incorrect. And if conductivity is off, the effectiveness of the treatment is reduced and patient electrolyte balance can be altered. During observation in the Patient Treatment Room between 10:15 a.m. and 2:00 p.m., the following was revealed: - PCT AA was observed during preparation of the hemodialysis machines/extracorporeal circuits [the tubing, blood pump, heparin (blood thinner) pump, artificial kidney, and monitors for blood flow, blood pressure, and air bubbles] at Station (S) 2, S3, and S4 for the second shift patients (P#2, P#3, and P#4). - PCT AA was also observed during initiation of P#2, P#3, and P#4’s dialysis treatment. - PCT AA did not independently test pH and conductivity of final dialysate utilizing appropriate test strips and meter prior to each patient treatment. - PCT BB was observed during preparation of the hemodialysis machines/extracorporeal circuits at S7, S8, and S10 for the second shift patients (P#7, P#8, and P#10). - PCT BB was also observed during initiation of P#7, P#8, and P#10’s dialysis treatment. - PCT BB did not independently test pH and conductivity of final dialysate utilizing appropriate test strips and meter prior to each patient treatment. - LPN AA was observed during preparation of the hemodialysis machine/extracorporeal circuit at S14 for P#14. - LPN AA was also observed during initiation of P#14’s dialysis treatment. - LPN AA did not independently test pH and conductivity of final dialysate utilizing appropriate test strip and meter prior to P#14’s treatment. During staff interviews on 7/17/24, the following was revealed: - At 2:25 p.m., PCT AA was asked why he did not independently check the dialysate pH and conductivity on machines at S2, S3, and S4. He stated “we were taught to check our dialysis machines one time before the first shift patients get on the machine. Everyone here does it the same way, one time in the morning”. - At 2:55 p.m., PCT BB stated “I am a Preceptor and I was trained to check my dialysis machines for pH and conductivity before each shift. However, we were told here that we only have to check the pH and conductivity in the morning before the first shift patients get on the machine”. - At 3:20 p.m., LPN AA stated “the machines are checked every morning, it is also done like this at another sister facility (named) as well. Everyone does it every morning”. - At 3:47 p.m., the Charge Nurse was asked about performing pH and condictivity once daily, she stated “the Facility Administrator is responsible for training the staff. Yes, we only test the dialysis machines once in the morning for pH and conductivity”. - At 5:20 p.m., the Director of Operations (DO) was notified that staff was manually checking the dialysate pH and conductivity on dialysis machines once a day (in the morning only, before the first shift treatment starts). The DO stated “yes, okay”. A review of the Fresenius Medical Care 2008K Hemodialysis Machine Operator’s Manual, page 14 stated: The operator should always check conductivity and approximate pH of the dialysate with an independent device prior to initiating treatment and whenever concentrates are changed during operation. A review of Policy 1-03-02 titled, “Testing pH and Conductivity of Proportioned Dialysate and Verification of Temperature of Proportioned Dialysate” dated 2020 stated: Notes: * Manual pH testing must be performed prior to each patient treatment. * Requiement for independent conductivity testing is determined by Manufacturer’s guidelines. Refer to specific hemodialysis machine priming policies and procedures to determine the requirement of performing independent conductivity testing in the facility. Policy: 1. Trained teammates will test pH and conductivity of final dialysate utilizing appropriate test strips and/ or meter proir to each patient treatment.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jul 18, 2024 | Complaint inspection | 3 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Dec 21, 2006.
- Run for profit.
- Cited at For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. in the last three years: it didn’t meet a whole condition of Medicare’s rules for dialysis facilities.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- 3 deficiencies cited in the last three years came from inspections that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 16 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 25 dialysis facilities CMS lists in Dekalb County, 24 have a star rating from CMS: 1 rated 5 of 5, 4 rated 4 of 5, 11 rated 3 of 5, 6 rated 2 of 5, 2 rated 1 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.