The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 6 deficiencies in 1 month of the last 36. Last cited May 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on May 1, 2024: a standard inspection.

6 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 1 month of the last 36. Last cited May 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

May 1, 2024: standard inspection6 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 215 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 44819 Based on observation, policy review, and staff interview, it was determined that the facility failed to perform hand hygiene during patient care for 1 of 10 (Patient #2) patient care observations. Findings include: Facility policy titled “Hand Hygiene” dated 11/6/2023 stated, “...Hands will be decontaminated...before...direct contact with patients...after contact with inanimate objects near the patient...” Facility policy titled “Post Treatment Fistula Needle Removal” dated 7/6/2021 stated, “...Person removing needles perform hand hygiene and don clean gloves...” Patient #2 During observation of the discontinuation of dialysis treatment on 4/29/24 between 9:45 AM and 10:25 AM, Employee #2 was observed completing the following tasks: - performed hand hygiene and donned clean gloves - returned Patient #2’s blood - clamped bloodlines and needle lines, then removed the bloodlines from the needle lines and removed Patient #2’s first needle - discarded the needle then removed his/her gloves and performed hand hygiene Employee #2 failed to perform hand hygiene and change gloves before removing Patient #2’s needle. Employee #2 confirmed this finding on 4/29/24 at 10:25 AM.”

    Rule V0113. Standard-level.

  • Ic - Sinks Available

    The inspectors’ words, 160 words

    “IC-SINKS AVAILABLE CFR(s): 494.30(a)(1)(i) A sufficient number of sinks with warm water and soap should be available to facilitate hand washing. This Standard is not met as evidenced by: 48349 Based on observation, policy review, and staff interview, it was determined that the facility failed to ensure that soap was available to facilitate hand washing for 1 of 1 handwashing sinks in the “Lab Room.” Findings include: Facility policy titled “Hand Hygiene” dated 11/06/2023 stated, “...Sink Policy...Soap and a supply of paper towels protected from contamination must be available at each sink ...” During a tour of the facility on 4/29/24 between 9:15 AM and 9:25 AM in the room labeled “Lab Room,” it was observed that no hand soap was available at the handwashing sink. The canister which holds the hand soap was empty and no soap refills were located in the “Lab Room”. During an Interview on 4/30/24 at 8:31 AM, Employee # 8 confirmed the above finding.”

    Rule V0114. Standard-level.

  • Pe - Safe, Functional, Comfortable Environment

    The inspectors’ words, 358 words

    “PE-SAFE/FUNCTIONAL/COMFORTABLE ENVIRONMENT CFR(s): 494.60 The dialysis facility must be designed, constructed, equipped, and maintained to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment. This Standard is not met as evidenced by: 48349 Based on observation, policy review, and staff interview, it was determined that the facility failed to maintain a safe and sanitary environment for 31 of 31 patients at the dialysis facility on 4/29/24 and 4/30/24. Findings include: Facility policy titled “Storage of Supplies” dated 4/05/2021 stated, “...Proper storage conditions are necessary to provide a safe environment and to ensure supplies are not expired, contaminated, or damaged...All clean or sterile supplies...must be stored off the floor and a minimum of eighteen inches in a sprinklered facility from the ceiling...All liquid supplies must be stored separate from dry supplies to minimize damage from accidental breakage or spill...” Facility policy titled “General Cleanliness and Infection Control Guidelines” dated 2/7/22 stated, “...All areas must be kept clean and organized...solutions will be stored and labeled per policy...” During a flash tour of the room labeled “Janitor Closet” on 4/29/24 between 9:25 AM and 9:35 AM, the following was observed: - A bottle of Clorox Bleach cleaning product was stored on a shelf next to a large roll of hand paper towels. The roll of hand paper towels had a visible wet spot, 4 inches in diameter, on the side of the roll and was positioned next to the bottle of Clorox Bleach cleaning product. - A cardboard box was stored less than 18 inches (approximately 6 inches) from a sprinkler head. - A spray bottle with an unknown liquid inside was not labeled with the contents. During an interview on 4/29/24 at 9:41 AM, Employee #8 confirmed the above findings. During a tour of the room labeled “Storage” and “Training Room” on 4/30/24 between 10:18 AM and 10:33 AM, the following was observed: - Three (3) open paint cans were stored on the floor. - A rag in the corner of the room was covered with rodent feces. During an interview on 4/30/24 between 10:20 AM and 10:33 AM, Employee #15 confirmed the above findings.”

    Rule V0401. Standard-level.

  • Pe - Building - Constructed/Maintained To Ensure Safety

    The inspectors’ words, 145 words

    “PE-BUILDING-CONSTRUCT/MAINTAIN FOR SAFETY CFR(s): 494.60(a) The building in which dialysis services are furnished must be constructed and maintained to ensure the safety of the patients, the staff and the public. This Standard is not met as evidenced by: 44819 Based on observation and staff interview, it was determined that the Facility failed to maintain its facility to ensure the safety of 31 of 31 patients at the dialysis facility on 4/29/24 and 4/30/24. According to the 2012 Life Safety Code, “...Main and feeder circuit breakers are inspected annually...” During a facility tour on 4/30/24 between 10:18 AM and 10:33 AM it was observed that the main electrical panel was last inspected on 8/21/2017. Upon request, the Facility could not provide evidence that the main electrical panel has been inspected annually since 8/21/2017. During an interview on 4/30/24 at 10:33 AM, Employee #15 confirmed this finding.”

    Rule V0402. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 594 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 48349 Based on observation, policy and document review, and staff interview, it was determined that for 32 of 32 current patients, the facility failed to ensure that supplies and equipment were maintained according to the manufacturer’s directions for use and/or were used within the manufacturer’s recommended expiration dates. Findings include: I. Expired Supplies in “Lab Room” Facility policy titled “Storage of Supplies” dated 4/05/2021 stated, “...Proper storage conditions are necessary to provide a safe environment and to ensure supplies are not expired, contaminated or damaged...Supplies must be rotated First-in-First Out (FIFO) to ensure products maintain quality and do not expire. Appropriately dispose of items that have reached the expiration date...” A flash tour of the room labeled “Lab Room” was completed on 4/29/24 between 9:15 AM and 09:24 AM. It was observed that a total of eight (8) blood draw tubes were expired. The expired items included: - Seven (7) “BD Vacutainer no additive” tubes (Lot #2259048, Reference # 366703) with an expiration date of 3/31/24. - One (1) “BD Vacutainer K2 EDTA” tube, (Lot # 2321385, Reference # 367861) with an expiration date of 3/31/24. During an interview on 4/29/24 at 9:39 AM, Employee #8 confirmed the above findings. II. Expired Supplies on Emergency Cart Facility policy titled “Emergency Medications, Equipment and Supplies” dated 05/01/2023 stated, “...Emergency Cart...Items approaching expiration must be reordered and replaced prior to the actual expiration date...” During an inspection of the facility’s emergency cart on 4/29/24 between 10:13 AM and 10:44 AM it was observed that 6 out of 12 “Sysloc Mini Safety A.V. Fistula Needle Sets” (Lot # 190328331, Reference # 864-1500-33) located in the emergency cart had an expiration date of 3/28/2024. During an interview on 4/29/24 between 10:38 AM and 10:44 AM, Employee #6 confirmed the above finding. III. Storage room with equipment not labeled for use. Facility policy titled, “Use of Hemodialysis & Ancillary Machine Repair/Return Tag” dated 11/04/2019 stated, “...The Standard Repair Request tag will be filled out and affixed to the hemodialysis machine or ancillary equipment whenever it is removed from service...Only the Standard Repair Request tag will be used to label machines removed from service. No other tagging system will be used... The Standard Ready for Use tag will be filled out and affixed to the hemodialysis machine or ancillary equipment whenever a machine is ready to return to service...” During a tour of the “Storage Room” on 4/30/24, it was observed that numerous pieces of equipment were not labeled for use. It could not to be determined if the equipment needed service or was ready for use. The equipment not labeled for use included: - Hoyer lift with inspection sticker dated “due” on 7-2021 (Serial # 1004L0567, Model #HPL 402) - Hoyer lift with inspection sticker dated “due” on 10/2023 (Serial # 1902L0692, Model #HPL902) - Portable RO Machine, Manufacturer “Better Water LLC” (Serial #1410144) - Portable RO Manufacturer, Manufacturer “Better Water LLC” (Serial #1410140) - Portable RO Manufacturer “Mar Cor” Serial #1320284 not labeled for use - Water Quality Monitor, Manufacturer “Better Water LLC” (Model #EQRO-1232-2800- 01001 Serial #EQR01508006) - Helmer medication fridge (Asset #2127773) - Three (3) Tan recliner chairs, Manufacturer “Winco” During an interview on 4/29/24 between 10:18 AM and 12:05 PM, Employee #15 confirmed the above findings.”

    Rule V0403. Standard-level.

  • Manage Anemia/H/H Measured Monthly

    The inspectors’ words, 278 words

    “POC-MANAGE ANEMIA/H/H MEASURED Q MO CFR(s): 494.90(a)(4) The interdisciplinary team must provide the necessary care and services to achieve and sustain the clinically appropriate hemoglobin/hematocrit level. The patient’s hemoglobin/hematocrit must be measured at least monthly. The dialysis facility must conduct an evaluation of the patient’s anemia management needs. This Standard is not met as evidenced by: 44819 Based on medical record review, Facility policy and protocol review, and staff interview, it was determined that for 1 of 4 patients (Patient #1) in the medical record review sample, the interdisciplinary team failed to ensure services to achieve the desired/appropriate hemoglobin level goal. Findings include: Facility algorithm titled “Corporate MAB [CMAB] Recommended Anemia Algorithm Mircera IVP [intravenous push] Administration (InCenter Only) Version 4.0” dated August 2019 documents that when the hemoglobin level is between 10.6 and 11.2, the Mircera dose should be decreased from maintenance dose of 60 mcg (micrograms) to 50 mcg every 2 weeks. Patient #1 Medical record review revealed: - Physician orders dated 5/1/2023 for CMAB recommended anemia algorithm for Mircera IVP Administration (InCenter only) version 4.0 - ESA (erythropoietin-stimulating agent) details in the “Treatment Sheet” dated 4/8/24 documented the patient is to receive Mircera 60 mcg IVP (intravenous push) every 2 weeks with the last dose received on 4/1/24. - Report of hemoglobin value dated 4/10/24 documents result of 10.7. According to the ordered algorithm, the next Mircera dose should be decreased to 50 mcg. - “Treatment Sheet” dated 4/15/24 documents patient received 60 mcg Mircera. During an interview on 5/1/24 at 10:05 AM, Employee #8 confirmed that staff failed to follow the ordered protocol to decrease Patient #1’s Mircera dose to 50 mcg on 4/15/24.”

    Rule V0547. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
May 1, 2024Standard inspection6 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Jun 22, 2018.
  • Run as a non-profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 12 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 20 dialysis facilities CMS lists in New Castle County, 16 have a star rating from CMS: 2 rated 5 of 5, 2 rated 4 of 5, 7 rated 3 of 5, 5 rated 2 of 5.
  • CMS rates this one 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.