Fkc North Wilmington
A dialysis facility in Wilmington, Delaware 19802
4000 Washington Street, Wilmington, Delaware 19802. (302) 762-2903.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 2of 5 CMS’s star rating
- Not rated patient survey rating
- 4 deficiencies cited in the last three years (needs attention)
- 17 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean4
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
- Condition-level deficiency
- For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.
What did inspectors find?
The last inspection on record was on Sep 27, 2024: a complaint and standard inspection.
4 deficiencies cited in the last three years, 1 of them at condition level, the most serious.
1 deficiency at condition level, the more serious of CMS’s two levels
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
4 deficiencies in 1 month of the last 36. Last cited Sep 2024. Most serious: Condition-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Sep 27, 2024: complaint and standard inspection4 deficiencies
-
Cfc - Physical Environment
The inspectors’ words, 283 words
“CFC-PHYSICAL ENVIRONMENT CFR(s): 494.60 This Condition is not met as evidenced by: 22676 Based on observation, staff interview, review of facility documents, and policy review, the facility failed to meet the Conditions for Coverage (CFC) when the facility did not 1. Ensure patients’ hemodialysis access sites were visible for one of three days of the survey. The patient and the access site (faces, needle insertion sites and line connections) must always be visible to staff during treatment, to ensure the lines and needles do not become dislodged or disconnected. Excessive blood loss can result from needle dislodgement, resulting in dire consequences such as severe hypotension, hospitalization, blood transfusions, and death, and could affect all 53 in-center hemodialysis patients receiving care at the facility. Following confirmation of the Immediate Jeopardy (IJ) with the State Survey Agency, the Covering Director of Operation and the Covering Facility Administrator were informed on 09/26/24 at 3:45 PM that an IJ at V407 was identified. The facility was informed it failed to meet the CfC for Physical Environment. A copy of the IJ template was provided by email at that time. The facility provided an acceptable plan for removal on 09/26/24 at 4:15 PM. The surveyor validated the facility implementation of the plan for removal. The Covering Director of Operations and the Covering Facility Administrator were notified that the interventions identified in the removal plan were reviewed and verified as implemented, and the IJ was removed at 09/27/24 at 3:40 PM. Finding Include: 1. The facility failed to ensure that Patient 1’s face and access were constantly in view and that the patient was not in a non-see-through privacy barrier alone and not constantly attended. Refer to Tag V407.”
-
Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols
The inspectors’ words, 421 words
“IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 22676 Based on observation, interview, facility policy review, and review of Centers for Disease Control (CDC) guidance, the facility failed to ensure that the wall boxes (dispensing outlets) of 16 of 16 dialysis (Station 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, and 16) stations observed were clean and free of a build-up of a dark yellow substance. This deficient practice had the potential to cause bacteria to grow in the wall boxes and could potentially affect the 53 patients receiving in-center hemodialysis at the facility. Findings include: During an observation of all wall boxes on 09/26/24 at 10:45 AM, at Stations 1, 2, 2, 3, 4, 6, 7, 8. 9, 10, 11, 12, 13, 14, 15, and 16, revealed a dark yellow sediment build-up on the bottom of the wall boxes. During an interview on 09/26/24 at 12:30 PM the Area Biomedical Technician Manager confirmed the above findings. He/she stated the staff were supposed to clean the wall boxes daily. Review of the facility policy titled, “Cleaning and Disinfection of the Dialysis Station”, dated 09/05/23, indicated, “Dialysis wall boxes and the area/wall around the wall box must be routinely cleaned at the end of each treatment day or immediately if splattered with blood. All surfaces shall be surface disinfected with 1:100 bleach solution. Special attention should be given, to removing build-up and/or cleaning splatter and spray of concentrate solution. If concentrate leaks are noted at the wall box, staff should notify biomedical services for repair.” Review of the “CDC Dialysis Safety” located on the CDC website at www.cdc.gov titled, “Wall boxes and Drains” page last reviewed: October 25, 2019, indicated, “All box surfaces should be disinfected at least daily (e.g., at the end of the day after all patients have dialyzed); cleaning and disinfection might be needed more frequently (e.g., when visibly dirty). Cleaning and disinfection of the wall box should be performed after the patient has left the station, and not during patient care activities. . . More than one disinfectant wipe or application may be needed to ensure all wall box surfaces are visibly wet with disinfectant to achieve contact time specified by the manufacturer.””
-
Pe - Hemodialysis Patients In View During Treatments
The inspectors’ words, 664 words
“PE-HD PTS IN VIEW DURING TREATMENTS CFR(s): 494.60(c)(4) Patients must be in view of staff during hemodialysis treatment to ensure patient safety, (video surveillance will not meet this requirement). This Standard is not met as evidenced by: 22676 Based on observation, staff interview, review of facility documents, and policy review, the facility failed to ensure the patient’s face and access were visible by having the patient seated in a non-see-through barrier for all times for one of three days of the survey. The patient and the access site (faces, needle insertion sites and line connections) must always be visible to staff during treatment, to ensure the lines and needles do not become dislodged or disconnected. Excessive blood loss can result from needle dislodgement, resulting in dire consequences such as severe hypotension, hospitalization, blood transfusions, and death, and could affect all 53 in-center hemodialysis patients receiving care at the facility. Findings: Observation in the treatment unit on 09/26/24 from 9:40 through 10:50 AM revealed the following information: At 9:55 AM, Patient (P) 1 at Station 12 was observed behind a non-see-through barrier that covered all the way around the patient with only a small corner section open. The patient could only be seen standing in front of the corner opening. Patient Care Technician (PCT) 8 was seen coming out of the patient barrier at 9:59 AM. The staff were all observed caring for other patients in the bay and were not seen back in the barrier with P1 until 10:25 AM. Staff could not visualize the patients’ face and access, unless they were in the barrier with the patient. Inability to observe the patient has the potential for patient access to become dislodged resulting in increased bleeding and potentially death. Review of P1’s treatment sheet for 09/26/24 revealed that staff was present in the barrier at 9:57 AM and the patient blood pressure was noted to be 89/58. They were not back in the barrier until 10:28 AM and the patient’s blood pressure was still low at 82/64. During an interview with PCT8 on 09/26/24 at 10:40 AM, he/she stated the patient was in the barrier because he was COVID-19 positive. He/she confirmed that the patient could not be seen unless standing directly in front of the corner opening. In an interview with Charge Nurse (CN) 7 on 09/26/24 at 10:45 AM, he/she stated they had been instructed to use the non-see-through privacy barriers for COVID-19 positive patients. He/she stated they were told they could not use the isolation room even though they currently do not have a positive hepatitis B patent. He/she agreed the patients could not be visualized through the non-see-through privacy barriers. He/she stated the facility did not have a positive hepatitis B patient on census. Review of the facility’s policy titled, “Guidance on Dialysis and Infection control Practices of COVID-19 in Fresenius Care (FKC) Dialysis Clinic,” date 04/30/24 indicated, “COVID-19 positive patients may be cohorted and treated within their home clinic treatment shifts with appropriate infection control precautions in place. The patients that are cohorted should be separated by a minimum of 6 feet from the nearest patient in all directions and ideally by a physical barrier, separate pod, or other top barriers between classifications of patients. COVID-19 positive patients and PUI [persons under investigation] patients may be treated in an unused isolation room within the clinic, following other infection control guidelines within this policy: Hepatitis B isolation rooms should only be used for patients with COVID-19 symptoms if: The patient is hepatitis B surface antigen positive OR the facility has no patient on census with a hepatitis B infection who require treatment in the isolation room. A review of the facility’s policy titled, “Patient Assessment and Monitoring,” dated 05/01/23, revealed, “All patients must be under direct visual observation by clinical staff during treatment. The lighting in the dialysis facility must allow for the ability to observe patients in the treatment area. Ensure each patient’s face is visible and uncovered ...””
-
Appropriateness Of Dialysis Rx
The inspectors’ words, 309 words
“PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 22676 Based on medical record reviews, interview, and policy review, the facility failed to follow the individualized dialysis (an artificial means of kidney function that removes the waste and excess fluid from the blood by passing through a filter) prescription as determined by the medical provider for one of six sampled in-center dialysis patients (Patient (P8). Failure to follow the medical providers’ dialysis prescription had the potential to negatively impact on the effectiveness of the prescribed dialysis treatments for all 53 patients receiving in-center dialysis treatments at this facility. Findings include: A review of P8’s electronic medical record (EMR) revealed a prescribed Blood Flow Rate (BFR) of 400 milliliters per minute (ml/min) and Dialysate Flow Rate (DFR) of 600 ml/min. A review of two of six “Post Treatment” flowsheets from 06/11/24 through 09/12/24 in the EMR indicated the following: a. On 06/11/24, the DFR was documented at 800 ml/min from 12:47 PM until 1:37 PM. b. On 09/12/24, the BFR was documented at 450 ml/min from 1:30 PM through 3:40 PM. There was no documentation for the change to the prescribed DFR and BFR. During an interview on 09/27/24 at 3:15 PM, the Covering Facility Administrator 3 confirmed the above findings and confirmed that the staff did not follow the physician’s order for dialysis treatment. A review of the facility’s policy titled, “Patient Assessment and Monitoring,” dated 05/01/23, revealed, “Check Machines settings and measurements: Check prescribed blood flow is being archived or reason is documented in the medical record if unable to meet prescribed blood flow rate. Check dialysate flow rate setting is correct, and the correct prescribed flow is being delivered ...””
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Sep 27, 2024 | Complaint and standard inspection | 4 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on May 14, 2008.
- Run for profit.
- Cited at For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. in the last three years: it didn’t meet a whole condition of Medicare’s rules for dialysis facilities.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- 4 deficiencies cited in the last three years came from inspections that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis and a shift starting at 5 p.m. or later.
- Doesn’t offer peritoneal dialysis and home hemodialysis training.
- 17 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 2 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 20 dialysis facilities CMS lists in New Castle County, 16 have a star rating from CMS: 2 rated 5 of 5, 2 rated 4 of 5, 7 rated 3 of 5, 5 rated 2 of 5.
- CMS rates this one 2 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Fkc Riverside Park | 3 |
| Christiana Care Health System | Not given |
| Nemours Children’s Health | Not given |
| Fkc Brandywine | 3 |
| Fkc Christiana | 2 |
| Fkc First State | 3 |
| Fkc Wilmington | 3 |
| Fkc Newport Pike | 4 |
| Fkc Middletown | 3 |
| Usrc Wilmington | 3 |
| Fkc Brandywine Home Therapies | 3 |
| Fkc Fox Run | 5 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.