Hearth Record

Fkc Middletown

A dialysis facility in Middletown, Delaware 19709

104 Sleepy Hollow Drive, Suite 100, Middletown, Delaware 19709. (302) 449-1601.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 3 deficiencies in 1 month of the last 36. Last cited Feb 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Feb 12, 2025: a standard inspection.

3 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

3 deficiencies in 1 month of the last 36. Last cited Feb 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

3 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Feb 12, 2025: standard inspection3 deficiencies
  • Dialysis Emergency Equipment

    The inspectors’ words, 390 words

    “Dialysis Emergency Equipment CFR(s): §494.62(b)(9) Condition for Coverage: [(b) Policies and procedures. The dialysis facility must develop and implement emergency preparedness policies and procedures, based on the emergency plan set forth in paragraph (a) of this section, risk assessment at paragraph (a)(1) of this section, and the communication plan at paragraph (c) of this section. The policies and procedures must be reviewed and updated at least every 2 years. At a minimum, the policies and procedures must address the following:] (9) A process by which the staff can confirm that emergency equipment, including, but not limited to, oxygen, airways, suction, defibrillator or automated external defibrillator, artificial resuscitator, and emergency drugs, are on the premises at all times and immediately available. This Standard is not met as evidenced by: 52387 Based on observation, interview and review of facility’s policy and procedure, facility’s staff failed to maintain emergency supplies in one of one emergency cart located in the facility’s home dialysis suite. Findings include: 1.Observation on 02/11/25 at 9:22 AM in the facility’s home dialysis suite revealed an emergency cart containing emergency supplies. Observation in a drawer labelled “six” of the emergency cart revealed a Bemis suction container (reference number 424410) with and expiration date of 08/01/20. Interview with Registered Nurse (RN) 18 who was present during the observation stated, “ I did not know the Bemis suction container was expired.” 2. Observation on 02/11/25 at 9:28 AM of the facility’s home hemodialysis treatment room revealed a storage cupboard. Observation of the cupboard revealed three standard infusion sets with Lot #s (32483401) and expiration date of 11/30/24, The infusion sets were co-mingled with unexpired patients’ supplies. Interview with RN18 revealed he/she had checked the cupboard but did not identify that the infusions sets were expired. Review of the facility’s policy and procedure titled “Emergency Medications, Equipment and Supplies,” revised on 02/03/25 directs staff as follows: “Purpose. The purpose of this policy is to provide guidelines for staff when determining and maintaining emergency equipment and supplies. . .The following minimum emergency supplies and equipment must be on the premises at all times, clean functional accessible and immediately available: Automated External Defibrillator (AED) Oxygen, tubing, and masks/cannulas Emergency medications Suction machine, disposable catheter, and canisters Disposable Ambu Bag with face mask IV solutions and administrative sets Cardiac {back board} Oral airway CPR pocket mask.””

    Rule E0028. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 270 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 22676 Based on review of glucometer logs, interview, review of glucometer policy, and manufacturer’s instructions, the facility failed to ensure the glucometer was in the correct control range and follow manufacturer’s instructions for one of one glucometer used in the facility. This deficient practice had the potential to provide incorrect blood glucose results and could result in inaccurate glucose level results for all 69 incenter patients receiving care at the facility. Findings included: Review of electronic “Blood Glucose Logs” for the treatment unit, from 01/02/25 through 01/31/25 revealed the following: Review of the meter for the treatment unit labeled serial number AN-GM-04084-907 for January revealed: on 01/18/25, the recorded acceptable low control range was 86-116, the recorded low control was 118. There was no documentation that the low-level and high-level control had been repeated. During an interview on 02/11/25 at 1:30 PM, the Facility Administrator confirmed the findings and agreed the staff did not repeat the low-level and high-level control as required by the manufacturer’s instruction. Review of the facility’s policy titled, “Blood Glucose Monitoring Device,” dated 11/06/2023, revealed ...Reviewing the glucometer instructions for use ... Review of the “Embrace Pro” blood glucose monitoring system manufactures instruction revision date 09/2020 revealed, “ ...p. eleven, if the “test fall outside the range printed on the test strip vial, repeat the test ...””

    Rule V0403. Standard-level.

  • Achieve Adequate Clearance

    The inspectors’ words, 315 words

    “POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 22676 Based on medical record reviews, interviews, and policy review, the facility failed to follow the individualized dialysis (an artificial means of kidney function that removes the waste and excess fluid from the blood by passing through a filter) prescription as determined by the medical provider for one of five sampled in-center dialysis patients (Patient (P)3). Failure to follow the medical providers’ plan for the dialysis prescription had the potential to negatively impact on the effectiveness of the prescribed dialysis treatments for all 69 patients receiving in-center dialysis treatments at this facility. Findings include: A review of P3’s electronic medical record (EMR) revealed a prescribed Blood Flow Rate (BFR) of 400 milliliters per minute (ml/min). A review of two of six “Post Treatment” flowsheets from 02/01/25/ through 02/12/25 in the EMR indicated the following: a. On 02/01/25, the BFR was documented at 350 ml/min from 07:49 AM until 11:39 AM. b. On 02/04/25. The BFR was documented at 350 ml/min from 8:300AM until 11:47 AM. There was no documentation for the change to the prescribed BFR. During an interview on 02/12/25 at 10:30 AM, the Charge Nurse II 3, confirmed the above findings and confirmed that the staff did not follow the physician’s plan for the dialysis treatments. A review of the facility’s policy titled, “Unable to Achieve Prescribed Blood Flow Rate” dated 11/01/21, revealed, “Notify physician/extender if unable to achieve prescribed blood flow rate. Document in the patient’s treatment record what action taken to address the inadequate blood flow and if unable to resolve. The nurse shall document any physician’s orders.””

    Rule V0544. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Feb 12, 2025Standard inspection3 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Jan 9, 2006.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
  • Doesn’t offer a shift starting at 5 p.m. or later.
  • 14 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 20 dialysis facilities CMS lists in New Castle County, 16 have a star rating from CMS: 2 rated 5 of 5, 2 rated 4 of 5, 7 rated 3 of 5, 5 rated 2 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.