Hearth Record

Fmc South Mobile

A dialysis facility in Grand Bay, Alabama 36541

12401 Skopelos Rd, Grand Bay, Alabama 36541. (251) 865-2102.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 6 deficiencies in 1 month of the last 36. Last cited Jul 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jul 18, 2025: a standard inspection.

6 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 1 month of the last 36. Last cited Jul 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jul 18, 2025: standard inspection6 deficiencies
  • Ic - Items Taken To Station Disposed/Dedicated Or Disinfected

    The inspectors’ words, 284 words

    “IC-IF TO STATION=DISP/DEDICATE OR DISINFECT CFR(s): 494.30(a)(1)(i) Items taken into the dialysis station should either be disposed of, dedicated for use only on a single patient, or cleaned and disinfected before being taken to a common clean area or used on another patient. -- Nondisposable items that cannot be cleaned and disinfected (e.g., adhesive tape, cloth covered blood pressure cuffs) should be dedicated for use only on a single patient. -- Unused medications (including multiple dose vials containing diluents) or supplies (syringes, alcohol swabs, etc.) taken to the patient’s station should be used only for that patient and should not be returned to a common clean area or used on other patients. This Standard is not met as evidenced by: 22676 Based on observation, interview, and policy review, the facility failed to ensure the hemostats and clamps used in patient care were disinfected appropriately. This increased the risk of cross contamination for 58 of 58 patients receiving care at the facility. Findings include: During a tour of the treatment floor on 07/16/25 at 9:30 AM, the blue clamps (hemostats) used in patient care were observed to be draining on a blue cloth next to the bleach container. There were numerous clamps in the pile that were observed to be in the closed position versus the open position to ensure adequate disinfection and drainage of the interior surface of the clamp. During an interview on 07/16/25 at 9:30 AM, the Administrator confirmed the clamps were to be in the open position during draining after disinfection. Review of the facility’s policy titled, “Cleaning and Disinfecting Plastic Hemostat Clamps and Vascular Clamp,” dated 07/01/24, revealed, “. . . Air dry in the opened position . . .””

    Rule V0116. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 444 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 22676 Based on observation, interview, facility policy review, and review of Centers for Disease Control (CDC) guidance, the facility failed to ensure that the wall boxes (dispensing outlets) at 25 of 25 dialysis stations (Station 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, and 25) were clean and free of a build-up of a dark yellow substance. This deficient practice had the potential to cause bacteria to grow in the wall boxes and could potentially affect 58 of 58 patients receiving in-center hemodialysis at the facility. Findings include: During an observation of all wall boxes on 07/16/25 at 9:15 AM, the wall boxes at Stations 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, and 25 were observed to have a dark yellow sediment build-up on the bottom of the wall boxes. During an interview on 07/16/25 at 9:15 AM, the Administrator confirmed the above findings. He/she stated the staff were supposed to clean the wall boxes daily. Review of the facility’s policy titled, “Cleaning and Disinfection of the Dialysis Station,” dated 09/05/23, indicated, “Dialysis wall boxes and the area/wall around the wall box must be routinely cleaned at the end of each treatment day or immediately if splattered with blood. All surfaces shall be surface disinfected with 1:100 bleach solution. Special attention should be given to removing build-up and/or cleaning splatter and spray of concentrate solution. If concentrate leaks are noted at the wall box, staff should notify biomedical services for repair.” Review of the “CDC Dialysis Safety,” located at www.cdc.gov and titled, “. . . Wall boxes and Drains,” dated October 25, 2019, indicated, “All box surfaces should be disinfected at least daily (e.g., at the end of the day after all patients have dialyzed); cleaning and disinfection might be needed more frequently (e.g., when visibly dirty). Cleaning and disinfection of the wall box should be performed after the patient has left the station, and not during patient care activities . . . More than one disinfectant wipe or application may be needed to ensure all wall box surfaces are visibly wet with disinfectant to achieve contact time specified by the manufacturer . . .””

    Rule V0122. Standard-level.

  • Environment: Secure And Restricted

    The inspectors’ words, 254 words

    “ENVIRONMENT-SECURE & RESTRICTED CFR(s): 494.40(a) 8 Environment: secure & restricted The water purification and storage system should be located in a secure area that is readily accessible to authorized users. The location should be chosen with a view to minimizing the length and complexity of the distribution system. Access to the purification system should be restricted to those individuals responsible for monitoring and maintenance of the system. This Standard is not met as evidenced by: 22676 Based on observation, interview, and policy review, the facility failed to restrict access to the water purification and storage system to only authorized users on one of three survey days. Failure to restrict access to the water treatment area has the potential to negatively impact the safety and well-being of 58 of 58 in-center dialysis patients receiving treatments at this facility. Findings include: During the flash tour observation on 07/16/25 at 10:30 AM, it was revealed the gate designated as the entrance to the water purification system and storage system was secured by a key lock entry. The key was observed to be in the lock, and the water room was not secure. During an interview on 07/16/25 at 10:30 AM, Biomedical Technician 6 confirmed the key was in the lock. He/she stated that the staff usually kept the key in a drawer in the Nurses station. Review of facility’s policy titled, “Physical Security and Facility,” dated 09/05/23, revealed,”. . . Restricted access must be maintained to prevent unwanted tampering with the water treatment equipment . . .””

    Rule V0184. Standard-level.

  • Mixing Systems - Cleaning

    The inspectors’ words, 263 words

    “MIXING SYSTEMS-CLEANING CFR(s): 494.40(a) 6.4.1 Mixing systems: cleaning Concentrate mixing equipment should be either: (1) completely emptied, cleaned, and disinfected according to the manufacturer’s instructions; or (2) cleaned and disinfected using a procedure demonstrated by the facility to be effective in routinely producing concentrate meeting [these regulations related to allowable bacterial and endotoxin levels]. The disinfection data should be recorded for each ...disinfection cycle using a dedicated log. This Standard is not met as evidenced by: 22676 Based on observation, interviews, and policy review, the facility failed to ensure that one of one bucket holding reverse osmosis (RO) water used to rinse acid container caps and wands was clean and failed to ensure 6 of 6 acid containers were rinsed and inverted to drain. This had the potential to cause harm to 58 of 58 in-center hemodialysis patients receiving care at the facility. Findings include: During a tour of the Storage Area on 07/16/25 at 10:30 AM, the following was found: 1. A gray bucket labeled “RO Water” was observed to have a buildup of a dark orange substance all around the bottom of the bucket. There were two caps and acid wands soaking in the bucket. 2. There were six empty acid containers all laying sideways on a cart and not inverted to drain. During an interview on 07/16/25 at 10:30 AM, Biomedical Technician 6 confirmed the above findings. Review of facility policy titled, “Acid Concentrate Storage and Handling,” dated 09/03/24, revealed, “. . . Place the rinsed containers on a shelf inverted to allow container to air dry . . .””

    Rule V0230. Standard-level.

  • Dialysate Proportioning - Monitor Ph/Conductivity

    The inspectors’ words, 258 words

    “DIALYS PROPORT-MONITOR PH/CONDUCTIVITY CFR(s): 494.40(a) 5.6 Dialysate proportioning: monitor pH/conductivity It is necessary for the operator to follow the manufacturer’s instructions regarding dialysate conductivity and to measure approximate pH with an independent method before starting the treatment of the next patient. This Standard is not met as evidenced by: 22676 Based on observation, interview, and review of the manufacturer’s direction for use, the facility failed to ensure that one of one bottle of Mesa lab 14.0 mS/cm (milli siemens per centimeter), used to check the conductivity of the Myron L[sic] D6 meter (a meter used to conduct the conductivity and PH), was not available for use after its’ expiration date. This had the potential to cause harm to 58 of 58 in-center hemodialysis patients receiving care at the facility. Findings include: During a tour of the Water Room on 07/16/25 at 9:00 AM, the following was found: 1. One bottle of 14.0 mS/cm conductivity solution with an open date of 05/09/25. Instructions on the bottle stated the solution expired 30 days from the date of opening. During an interview on 07/16/24 at 9:00 AM, the Administrator confirmed the conductivity solution was opened on 05/09/25 and expired 30 days after the date of opening. The Administrator stated they used the manufacturer’s instructions which were printed on the front of the bottle as the facility policy. Review of Mesa lab manufacturer’s instructions, dated 01/2023, revealed, “. . . 14.0 mS/cm solutions expire 30 days from opening . . .” These instructions were also printed on the front of the bottle.”

    Rule V0250. Standard-level.

  • Achieve Adequate Clearance

    The inspectors’ words, 393 words

    “POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 22676 Based on record review, interview, and policy review, the facility failed to follow the individualized dialysis plan (an artificial means of kidney function that removes the waste and excess fluid from the blood by passing through a filter) by following the physician prescription as determined by the medical provider for two of seven sampled in-center dialysis patients (Patient (P3) and P5). Failure to follow the medical providers’ dialysis prescription had the potential to negatively impact the effectiveness of the prescribed dialysis treatments for 58 of 58 patients receiving in-center dialysis treatments at this facility. Findings include: 1. Review of P3’s “Treatment Detail Report,” located in the electronic medical record (EMR), revealed a prescribed Dialysis Flow Rate (DFR) of 800 milliliters per minute (ml/min). Review of two of six flow sheets from 07/02/25 through 07/17/25 indicated the following: a. On 07/10/25 from 9:05 AM - 11:49 AM, the DFR was documented at 500 ml/min. b. On 07/15/25 from 7:58 AM - 11:46 AM, the DFR was documented at 500 ml/min. There was no documentation for the change from the prescribed DFR. 2. Review of P5’s “Treatment Detail Report,” located in the EMR, revealed a prescribed Blood Flow Rate (BFR) of 400 ml/min. Review of three of six flowsheets from 07/02/25 through 07/16/25 indicated the following: a. On 07/02/25 from 6:23 AM until 11:05 AM, the BFR was documented at 450 ml/min. b. On 07/04/25 from 6:22 AM until 10:52 AM, the BFR was documented at 450 ml/min. c. On 07/07/25 from 6:33 AM until 11:01 AM, the BFR was documented at 450 ml/min. There was no documentation for the change from the prescribed BFR. During an interview on 07/18/25 at 11:00 AM, the Administrator confirmed the above findings and stated that staff did not follow the physician’s order for dialysis treatments. Review of the facility’s policy titled, “Pre-Intra-Posttreatment Data, Collection, Monitoring and Nursing Assessment,” dated April 2024, stated, “. . . identity, prescription, and machine settings are verified by teammate . . . f. Blood flow rate . . .””

    Rule V0544. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jul 18, 2025Standard inspection6 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Apr 3, 2013.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 27 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 15 dialysis facilities CMS lists in Mobile County, 15 have a star rating from CMS: 3 rated 4 of 5, 7 rated 3 of 5, 4 rated 2 of 5, 1 rated 1 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.