Hearth Record

Fmc East Mobile

A dialysis facility in Mobile, Alabama 36604

1217 Government St, Mobile, Alabama 36604. (251) 438-6917.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 4 deficiencies in 1 month of the last 36. Last cited Jun 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jun 6, 2025: a standard inspection.

4 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

4 deficiencies in 1 month of the last 36. Last cited Jun 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

4 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jun 6, 2025: standard inspection4 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 369 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 28297 Based on observation, interview, and policy review, the facility failed to ensure patients washed or sanitized hands after holding access sites (A vascular access is created so that blood can be drawn from the body and run through a dialysis machine, where excess fluid and toxins are removed from the blood.) for one of three survey days. The failure for patients to wash or sanitize hands after holding access site had the potential for cross contamination and could affect 77 in-center patients. Findings include: Observation on 06/05/25 at 10:40 AM revealed Patient (P) 7 at Station 14 applied pressure to the left lower access site until bleeding had stopped. When the patient was finished, he/she walked to the scale to retrieve weight without staff involvement. Patient 7 did not wash or sanitize hands before leaving the facility. During an interview on 06/05/25 at 11:10 AM P7 stated no one had ever educated him/her about washing or sanitizing hands after holding access site prior to leaving the facility. During an interview on 06/06/25 at 2:20 PM Certified Clinical Hemodialysis Technician (CCHT) 3 stated patients were required to wash or sanitize hands after holding access sites prior to leaving the facility to prevent cross contamination in the facility and that patients were educated upon admission. During an interview on 06/06/25 at 4:45 PM the Clinical Manager stated patients should wash or sanitize hands after holding access sites at the end of treatment to prevent cross contamination of blood borne pathogens. Review of the facility’s policy titled, “Hand Hygiene” revised 11/06/23 indicated the following: “Patients should perform hand hygiene if able, prior to and after each dialysis treatment ...Gloves must be provided to patients when performing procedures which risk exposure to blood or body fluids, such as when self-canulating or holding access sites post treatment to achieve hemostasis. To help ensure the prevention of cross contamination to their family members or other patients, hand hygiene must be performed ...””

    Rule V0113. Standard-level.

  • Pe - Safe, Functional, Comfortable Environment

    The inspectors’ words, 817 words

    “PE-SAFE/FUNCTIONAL/COMFORTABLE ENVIRONMENT CFR(s): 494.60 The dialysis facility must be designed, constructed, equipped, and maintained to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment. This Standard is not met as evidenced by: 28297 Based on observation, interview, and review of facility policy, the facility failed to ensure there was an appropriate means for patients to notify staff of an emergency that could occur in the patient lobby for one of three survey days. The failure to have an appropriate means to contact staff in an emergency had the potential for adverse events such as bleeding, falls or other potential accidents not to be addressed in a timely manner and could affect 77 in-center patients. In addition, the facility failed to ensure one of 11 oxygen cylinders was not secured for one of three survey days. The failure to ensure oxygen cylinders were secured had the potential for one to fall and malfunction and this could impact 77 in-center patients. Findings include: 1. Observation on 06/04/25 from 8:20 AM until 8:30 AM revealed the surveyor entered the building into the patient lobby area. The surveyor knocked on the treatment room door a total of three times with the third time continuous and banging. The Administrative Assistant answered the door. There was no doorbell and the window to the treatment area was completely obscured except for a small peep hole. The surveyor called both the Clinical Manager and Director of Operations number that was posted in the lobby, however there was no answer. The Administrative Assistant opened the treatment floor door, and the surveyor continued observation of the treatment floor revealed the nurse’s station was 30 feet (measured by the Clinic Manager) from the lobby door. There was a wall that goes from the floor to the ceiling from station 1 (closest to the lobby door) and extends all the way down the treatment floor that impedes the ability to hear if someone was knocking on the treatment room door from the lobby. During an interview on 06/04/25 at 8:32 AM the Administrative Assistant stated he/she normally was at the front desk, however he/she was working as a Patient Care Technician on this day. During an interview on 06/05/25 at 11:15 AM the Clinical Manager stated the facility had cameras throughout the facility, however staff have to pull it up on their emails to see the lobby area and that there was no other way to monitor patients in the lobby area. He/she stated the computer screen that has all the cameras was in the electrical room at the back of the facility. During an interview on 06/05/25 at 3:00 PM the Medical Director stated he/she did not realize there was no way to visualize patients in the lobby unless staff pull it up on their email. He/she stated there have been security issues in the past. During an interview with Registered Nurse (RN) 2 on 06/06/25 at 2:55 PM revealed in order for staff to visualize patients in the lobby, you have to close several tabs on the computer to open up the email that has the cameras to view the lobby. RN 2 stated they put a bell in the lobby on 06/05/25, however it was not working consistently. Review of an email provided by the Clinical Manager dated 05/30/25 The Area Technical Operations Director (ATOM) emailed a company for a “quote for moving the existing monitor for the security system from the electrical room to the nurses station. As soon as I have the quote ill (sic) let you know.” Review of the facility policy “Security Policy” revised 07/05/22 indicated the following: “ ...Install cameras to record activity in or around the facility. Alert individuals that cameras are I use with appropriate signage ...” Review of facility policy “Physical Security and Facility Access,” revised 09/05/23 indicated the following: “ ...If it is deemed necessary, security camera or communication intercoms will be placed in appropriate areas within the facility ...” 2. Observation on 06/04/25 at 11:00 AM revealed one of 11 oxygen cylinders stored in the supply storage area was not secured in a holding device. During an interview on 06/04/25 at 12:00 PM the Area Technical Operations Manager (ATOM) confirmed the oxygen cylinder was not secured. He/she stated it should be, and everyone was responsible for making sure they were secure to prevent them from falling over. During an interview on 06/06/25 at 2:20 PM Certified Clinical Hemodialysis Technician (CCHT) 3 stated he/she was not aware oxygen cylinders needed to be secured to prevent them from falling over. During an interview on 06/06/25 at 4:45 PM the Clinical Manager stated the oxygen cylinders should be secure to prevent them from falling over. Review of the facility policy “Emergency Administration of Oxygen,” revised 11/01/21 indicated the following: “ ...Oxygen cylinders must be secured in an area where that will not fall ...””

    Rule V0401. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 372 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 28297 Based on observation, interview, policy review and Manufacture Directions for Use, the facility failed to ensure solutions used to calibrate the “Myron L D6 TDS Meter” for one of three survey days, were within date. The failure to have solutions within date had the potential for inaccurate reading of the meter and this could affect 77 in-center patients. Findings include: Observation on 06/04/25 at 10:45 AM revealed (Total Dissolved Solvents (TDS) conductivity solutions manufacture expiration date was June 21, 2024. The Standard Buffer solution 4.0 PH manufacture expiration date was 04/26/25, Conductivity standard solution 14.0 manufacture expiration date was 03/29/25 and standard buffer solution 7.0 manufacture expiration date expired 04/04/25. All were opened and dated 04/09/25 by Certified Clinical Hemodialysis Technician (CCHT) 3. During an interview on 06/04/25 at 11:05 AM CCHT 3 confirmed he/she opened and dated all the solutions on 04/09/25 and failed to look at the manufacture date. CCHT 3 stated the potential risk was that the meter could read inaccurately if using expired solutions. During an interview on 06/04/25 at 12:00 PM the Area Technical Operations Manager (ATOM) stated it was not the Biomedical staff’s responsibility to check supplies for expiration dates. During an interview on 06/06/25 at 4:45 PM the Clinical Manager stated it was direct care staff to check for expiration dates on items and solutions used in the clinic to ensure they were not expired. Review of the facility policy Myron L D6 Meter Maintenance Procedure,” revised 09/01/22 indicated the following: “ ...At the beginning of the day, check conductivity, TDS (442), and PH solution expiration dates. Discard expired solutions or solutions found without a cap. Use unexpired solutions for meter verification ...” Review of the “Myron L Company Standard Solutions Instructions,” undated indicated the following: “ ... Warranty All Myron L Standard Solutions have a shelf life of one year if stored unopened and according to instructions (see expiration date on bottle label) ...””

    Rule V0403. Standard-level.

  • Rd - Nutritional Status

    The inspectors’ words, 426 words

    “PA-RD-NUTRITIONAL STATUS CFR(s): 494.80(a)(6) The patient’s comprehensive assessment must include, but is not limited to, the following: (6) Evaluation of nutritional status by a dietitian This Standard is not met as evidenced by: 28297 Based on interviews, record review and review of facility policy, the facility failed to ensure one of six patients (P) 4 was started on a nutritional supplement in a timely manner. The failure to not start a nutritional supplement in a timely manner to aid in the improvement of albumin levels affected P4 and had the potential to affect all patients in the facility that require a nutritional supplement with low albumin levels. Findings include: Review of the medical record for P4 revealed the facility admitted the patient on 05/06/25 as a transfer from another facility. Review of P4 labs indicated on 05/05/25 the patient’s albumin was 2.9 grams/deciliter (g/dl). The goal for albumin in dialysis patients is >4.0 g/dl based on the Measure Assessment Tool (MAT) for dialysis patients. On 05/15/25 the albumin was 2.8 g/dl. On 05/22/25 Dietician 2 documented that he/she met with the patient. The Nutritional Notes dated 05/22/25 indicated the patient was on Oral Nutritional Supplement Program (ONSP). Reviews of six treatment flowsheets from 05/22/25 to 06/06/25 revealed P4 did not receive any nutritional supplement from the facility. During an interview on 06/06/25 at 12:26 PM Dietician 2 stated there had not been an order for a nutritional supplement at this facility since the patient was admitted (transferred). Dietician 2 stated they had seen the patient at chairside on 05/22/25 however there were other issues with the patient that day and they did not get to talk to the patient about what type of supplement the patient wanted and was going to get back with the patient at a later time. Dietician 2 said the nutritional note that said the patient was on a nutritional supplement was from the patient transfer facility and the patient last received a supplement on 05/02/25 at the previous facility. During an interview on 06/06/25 at 4:45 PM the Clinical Manager stated it was the Dietician responsibility to get the Nutritional Supplement ordered. Review of the facility policy titled “Oral Nutritional Supplements Program (ONSP),” revised 01/23/2023 indicated the following: “ ...Purpose: Administer oral nutritional supplements to FKC dialysis patients who meet the supplement criteria to: Improve nutritional status, ensure compliance with oral intake, Reduce the risk of morbidity and mortality ...Criteria starting and stopping Supplements: Albumin 3.5 g/dl or less or transfer patient with current oral nutrition supplement order at previous provide/clinic.””

    Rule V0509. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jun 6, 2025Standard inspection4 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Dec 1, 1985.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 29 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 3 of 5 in CMS’s survey of in-center hemodialysis patients (35 interviews, Oct 18, 2024 to Jul 11, 2025): 74% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 53 of 5

How does it compare nearby?

  • Of the 15 dialysis facilities CMS lists in Mobile County, 15 have a star rating from CMS: 3 rated 4 of 5, 7 rated 3 of 5, 4 rated 2 of 5, 1 rated 1 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.