Hearth Record

Back to Electric motors

Air Vent Incorporated electric motors

1 report to CPSC, the latest made Jul 8, 2021. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Jul 8, 2021the latest report was made
  • Jul 8, 2021the earliest
  • 0with the company’s comments
Brand
Air Vent Incorporated
Maker
McMillan Electric CompanyMakers, importers or sellers, as the reports name them
Product
Electric motorsOn their ownCPSC’s product type: Electric Motors (Separate) (code 819), in Home Maintenance and Structures: Tools & Hardware

By month

1 report from August 2020 to July 2021; the most in July 2021, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
July 20211

How badly anyone was hurt

  • Hurt, no treatment 1 CPSC: Injury, No First Aid or Medical Attention Received

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. Hurt, no treatment

    Made Jul 8, 2021, sent to the company Jul 23, 2021, published by CPSC Aug 6, 2021

    The product, in the report: Air Vent Incorporated Power Attic Ventilator Motor, Model Number F0512B2506, UPC Number 046388230233, white, motor diameter = 5-1/8”, motor housing height = 2-7/8”, shaft diameter = 1/2”, shaft length = 2-3/8”. Model F0512B2506 UPC 046388230233

    I received a replacement motor, p/n F0512B2506 from Air Vent, Inc. to replace a motor for an Air Vent attic ventilator that failed during the warranty period. The motor shaft on the new motor was much more difficult to turn than I expected, so before I swapped the motors, I applied 120vac power to the new motor on my workbench to confirm that it worked. After less than 5 seconds, a big spark came out of the motor housing, the circuit breaker blew, and the motor no longer worked. I can see inside the motor housing where the line and neutral power wires are shorted together and melted. I can also see that the insulation on the cordset was stripped way back so that there was no insulation or separation between the uninsulated hot and neutral wires inside the motor housing. There was definitely a problem with the way this motor was manufactured, and it could have caused a fire.

    Model
    F0512B2506
    UPC
    046388230233
    Serial number
    none found
    Bought from
    AirVent.com
    Bought
    May 24, 2021
    Where
    Grayslake, Illinois: Home/Apartment/Condominium
    Who was involved
    Age 59, Male
    The reporter’s relation to them
    Self
    As this report names them
    Brand Air Vent Incorporated, made or sold by McMillan Electric Company
    How badly, in CPSC’s words
    Injury, No First Aid or Medical Attention Received

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Electric motors

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.