Hearth Record

Back to Padlocks, chain locks or other locks

Porta, Inc. Elevator Interlock 32VV padlocks, chain locks or other locks

1 report to CPSC, the latest made Jan 29, 2018. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Jan 29, 2018the latest report was made
  • Jan 29, 2018the earliest
  • 0with the company’s comments
Brand
Porta, Inc. Elevator Interlock 32VV
Maker
Porta, IncMakers, importers or sellers, as the reports name them
Product
Padlocks, chain locks or other locksCPSC’s product type: Padlocks, Chain Locks or Other Locks (code 707), in Home Maintenance and Structures: Home Security

By month

1 report from February 2017 to January 2018; the most in January 2018, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
January 20181

How badly anyone was hurt

  • No one hurt 1 CPSC: Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No one hurt

    Made Jan 29, 2018, sent to the company May 2, 2018, published by CPSC May 16, 2018

    The product, in the report: Porta Inc elevator electro mechanical door lock

    A recently modified installation of the recalled EMDL with the replacement of the plastic lock with the metal lock has resulted in broken Beryllium Copper spring contacts. The problem is that the technician never removed the plastic cover of the EMDL to visually verify the engagement distance of the new metal lock into the EMDL. As a result of incorrect/unadjusted mounting of the EMDL, the spring contacts were pushed way beyond the metal contact plate and actually contacted the underside of the metal lock. The circuit was closed by the spring contacts touching the metal of the lock rather than the metal contact plate surface at the end of the new metal lock. Upon opening the door, the metal lock grabbed and distorted the spring contacts to the point where they were dragged back over the end of the metal lock and snapped away from the metal lock when they had clearance to do so. As a result of repeated cycling in this manner, the contacts broke and fell off, rendering the solenoid circuit inoperable.

    Model
    EMDL Elevator Interlock 32VV
    UPC
    3152415
    Serial number
    3152415
    Bought from
    Seasons Condominium
    Bought
    Jan 1, 2009, about then
    Where
    East Meadow, United States: Home/Apartment/Condominium
    Who was involved
    Age 67, Male
    The reporter’s relation to them
    Other Relative
    As this report names them
    Brand Porta, Inc. Elevator Interlock 32VV, made or sold by Porta, Inc
    How badly, in CPSC’s words
    Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Padlocks, chain locks or other locks

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.