FLUIDMASTER toilets
1 report to CPSC, the latest made May 29, 2022. A report isn’t a recall.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.
At a glance
From SaferProducts.gov, released Oct 25, 2026.
- 1report to CPSC
- May 29, 2022the latest report was made
- May 29, 2022the earliest
- 0with the company’s comments
- Brand
- FLUIDMASTER
- Maker
- FLUIDMASTER, INCMakers, importers or sellers, as the reports name them
- Product
- ToiletsCPSC’s product type: Toilets (code 649), in Home Maintenance and Structures: Plumbing & Bath
By month
The numbers, as a table
| Month | Reports |
|---|---|
| May 2022 | 1 |
How badly anyone was hurt
- Seen by a doctor or nurse 1 CPSC: Injury, Seen by Medical Professional
As each report says it, in short words; CPSC’s own words are under each.
The reports, as CPSC published them
Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.
Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.
CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.
-
Seen by a doctor or nurse Made May 29, 2022, sent to the company Jun 3, 2022, published by CPSC Jun 21, 2022
The product, in the report: The product is a FLUIDMASTER Toilet Fill Valve 401LG, it looks identical to the model 400 seen here: [REDACTED]
I was repairing our Fluidmaster 401LG Fill Valve, already installed in the toilet tank. The Fill Valve Cap Assembly was faulty and I decided to use a new Fill Valve as a donor for its Fill Valve Cap Assembly. I was sitting on the closed toilet lid, facing the tank, I held the solid section of the new Fluidmaster 401LG Fill Valve Body in my left hand, while pressing and turning the Fill Valve Cap Assembly with my right hand. The Valve Body is height adjustable by a molded threaded section below the solid section, it requires turning like a nut & bolt to change the length. I put the threaded shank end of the Valve Body, on the toilet lid, for extra support. As I was pressing and turning the top Fill Valve Cap Assembly, the entire adjustable section of the Valve Body collapsed. When it collapsed, the skin of my thigh and my pants were trapped in between the upper & lower section of the Valve Body, and the entire Fluidmaster 401LG Fill Valve was attached to my thigh. I was in shock and severe pain, I tried to pull the sections apart, but couldn’t. I tried to twist the sections as one would normally do to adjust the height, but that was even more painful. I was going to call 911, but decided to try once more to pull the sections apart, as I thought of the time it would take for them to arrive and that I would have to walk with the valve attached to my leg, I was finally able to free myself from the assembly. The skin was deeply damaged in a diameter the size of a nickel. The skin was white and the blood was pressed out of the area, I was concerned the section was turned into hamburger and would become necrotic from lack of blood flow and damaged capillaries. I sought medical attention.
- Model
- 401LG Fill Valve
- UPC
- 039961240118
- Serial number
- N/
A - Where
- BOCA RATON, Florida: Home/
Apartment/ Condominium - Who was involved
- Unknown
- The reporter’s relation to them
- Self
- As this report names them
- Brand FLUIDMASTER, made or sold by FLUIDMASTER, INC
- How badly, in CPSC’s words
- Injury, Seen by Medical Professional
CPSC’s disclaimer
Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.
Word for word, from the disclaimer in CPSC’s export.
Sources
Sources
-
U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.
Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.
Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.