Hearth Record

Back to Generators

Porter Cable generators

2 reports to CPSC, the latest made Oct 15, 2018. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 2reports to CPSC
  • Oct 15, 2018the latest report was made
  • Aug 28, 2011the earliest
  • 1with the company’s comments
Brand
Porter Cable
Maker
Black & Decker (U.S.) Inc.Makers, importers or sellers, as the reports name them
Product
GeneratorsIncluding power plantsCPSC’s product type: Generators or Power Plants (code 606), in Home Maintenance and Structures: Electrical Systems

By month

1 report from November 2017 to October 2018; the most in October 2018, 1. 1 earlier report, since August 2011, is in the table.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
October 20181
August 20111

How badly anyone was hurt

  • No one hurt 2 CPSC: Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No one hurt

    Made Oct 15, 2018, sent to the company Nov 9, 2018, published by CPSC Nov 27, 2018

    The product, in the report: Generator

    This 78 year old consumer is reporting his generator that he purchased sometime around 2010 from a lumber company in Aurora, Indiana. He states that there are 15 hours use on this generator. Saturday, October 13th, 2018 the consumer had been using the generator for approximately one and a half hours when the gas line from the gas tank to the engine came loose and gas flew out of the tank into the engine and at least a foot outward. The grommet had deteriorated and he only knew this when he placed his finger over the 3/8 of an inch opening to stop the gas from coming out. There are no injuries being reported The caller states that there is no guidance stating that the grommet should be replaced. He contacted the company and spoke with a representative who advised him that yes the grommet should be checked and replaced periodically. He is reporting this incident as a very serious There was no comment from the company regarding there being no guidance for this grommet and an inspection or replacement.

    Model
    H6501S-W
    Serial number
    2812022610
    Bought from
    Do It Best Lumber Company
    Bought
    Oct 13, 2010, about then
    Where
    Aurora, Indiana: Home/Apartment/Condominium
    Who was involved
    Age 78, Male
    The reporter’s relation to them
    Self
    As this report names them
    Brand Porter Cable, made or sold by Black & Decker (U.S.) Inc.
    How badly, in CPSC’s words
    Incident, No Injury
  2. No one hurt

    Made Aug 28, 2011, published by CPSC Sep 20, 2011

    The product, in the report: Porter Cable portable generator

    Rubber drain grommet on fuel tank broke and allowed fuel to drain completely out of tank all over product and ground.

    Model
    BSI550-W
    Serial number
    2212015162
    Bought from
    Home Depot, Pennsylvania
    Bought
    Aug 29, 2002, about then
    Where
    Doylestown, Pennsylvania: Home/Apartment/Condominium
    Who was involved
    Unspecified
    The reporter’s relation to them
    Unspecified
    As this report names them
    Brand Porter Cable, made or sold by Black & Decker (U.S.) Inc.
    How badly, in CPSC’s words
    Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Generators

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.