1 report to CPSC, the latest made May 28, 2026. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • May 28, 2026the latest report was made
  • May 28, 2026the earliest
  • 1with the company’s comments
Brand
HUANUO
Maker
BESTERGO INC.Makers, importers or sellers, as the reports name them
Product
Dressers, desks and chestsIncluding bureaus and buffetsCPSC’s product type: Desks, Dressers, Chests, Bureaus, or Buffets (code 604), in Furniture, Furnishings & Decorations: Furniture

By month

1 report from June 2025 to May 2026; the most in May 2026, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
May 20261

How badly anyone was hurt

  • No one hurt 1 CPSC: Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No one hurt

    Made May 28, 2026, sent to the company Jun 3, 2026, published by CPSC Jun 17, 2026

    The product, in the report: Electric standing desk, height adjustable desk. Product label identifies it as Electric Standing Desk. The desk uses an included 29V DC power supply to power the lift controller. The failed component was the included AC DC wall power supply. The power supply sparked on first use and the desk would not power on. After unplugging and inspecting the power supply, the internal circuit board showed visible charring, soot, and apparent electrical arcing or thermal damage. Amazon listing model or part number is USMSESD202N-80A-US-57. Physical product label model is ESD01-80A. Physical product serial number is 01011302009220. Product label lists input as 29V DC 1A. Product label lists production date as 02-2026. Manufacturer date code appears to be 2026-02-10. The included power supply model is YHPWR K24R10290100.

    After assembling a HUANUO 32” Small Electric Standing Desk purchased from Amazon, I plugged in the included AC/DC wall power supply for the first time. The power supply immediately sparked, and the desk would not power on or function.

    The failed power supply is labeled YHPWR K24R10290100. After unplugging it, I inspected the power supply and found visible internal damage on the circuit board, including charring/soot and apparent electrical arcing or thermal damage. Photos of the damaged power supply circuit board are attached.

    The desk itself appears to function when powered from an external 29V DC supply, so the failure appears to be with the included power supply rather than the desk frame or controller.

    There were no injuries, but this appears to be a serious safety concern. A mains-powered adapter sparking and showing internal burn damage during first use could have created a fire or shock hazard, especially if it had remained plugged in or failed near combustible material.

    The product was being used normally by an adult consumer during initial setup in a residence.

    Model
    ESD01-80A
    UPC
    840478827477
    Serial number
    01011302009220
    Bought from
    Amazon.com
    Bought
    May 26, 2026
    Where
    Georgetown, Texas: Home/Apartment/Condominium
    Who was involved
    Age 31, Male
    The reporter’s relation to them
    Self
    As this report names them
    Brand HUANUO, made or sold by BESTERGO INC.
    How badly, in CPSC’s words
    Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Dressers, desks and chests

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.