Hearth Record

Back to Other power-assisted cycles

Ridstar other power-assisted cycles

1 report to CPSC, the latest made Aug 6, 2025. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Aug 6, 2025the latest report was made
  • Aug 6, 2025the earliest
  • 0with the company’s comments
Brand
Ridstar
Maker
HUIZHOU OUMEIDA TRADE CO., LTD.Makers, importers or sellers, as the reports name them
Product
Other power-assisted cyclesCPSC’s product type: Power-assisted cycles, not elsewhere classified (code 5046), in Sports and Recreation: Recreational Vehicles (Unlicensed)

By month

1 report from September 2024 to August 2025; the most in August 2025, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
August 20251

How badly anyone was hurt

  • Seen by a doctor or nurse 1 CPSC: Injury, Seen by Medical Professional

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. Seen by a doctor or nurse

    Made Aug 6, 2025, sent to the company Aug 8, 2025, published by CPSC Aug 22, 2025

    The product, in the report: The product is a Q 20 Lite, 1000 watt electric moped sold online as an e-bike.

    My son was riding a Ridstar Q20 Lite bike and the front wheel fell off. The wheel was installed per the instructions and follow up instructional video, which I believe to be incorrect because the wheel retainer is not put into the axle in the instructions.

    Update 8/7/2025: I’d like to add to the subject report that my son received 4 stitches for a laceration received when his face skid across the pavement after the front wheel fell off of his Ridstar Q20 lite while traveling approximately 15 mph.

    The instructions to assemble the front wheel of the bike aren’t just unclear. I think they’re actually wrong.

    I’m an engineer with a professional engineering license. In my professional opinion, I believe there is a high likelihood that a child will die when the front wheel comes off of a bike traveling at close to top speed. It will happen despite the fact that their parents installed the front wheel in accordance with the instructions.

    Model
    Q20 Lite
    Bought from
    www.ridstar.com
    Bought
    Aug 1, 2025, about then
    Where
    Tega Cay, South Carolina: Street or Highway
    Who was involved
    Age 12, Male
    The reporter’s relation to them
    My Child
    As this report names them
    Brand Ridstar, made or sold by HUIZHOU OUMEIDA TRADE CO., LTD.
    How badly, in CPSC’s words
    Injury, Seen by Medical Professional

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Other power-assisted cycles

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.