INMOTION hoverboards and electric skateboards
3 reports to CPSC, the latest made May 11, 2026. A report isn’t a recall.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.
At a glance
From SaferProducts.gov, released Oct 25, 2026.
- 3reports to CPSC
- May 11, 2026the latest report was made
- Jul 17, 2024the earliest
- 0with the company’s comments
- Brand
- INMOTION
- Makers
- InMotion LLC and Hong Kong Lemotion Co. Ltd.Makers, importers or sellers, as the reports name them
- Product
- Hoverboards and electric skateboardsCPSC’s product type: Hoverboards and powered skateboards (code 5025), in Sports and Recreation: Cycling, Scooters, Skateboards & Skates
By month
The numbers, as a table
| Month | Reports |
|---|---|
| May 2026 | 1 |
| April 2026 | 1 |
| July 2024 | 1 |
How badly anyone was hurt
- Emergency room 1 CPSC: Injury, Emergency Department Treatment Received
- Seen by a doctor or nurse 1 CPSC: Injury, Seen by Medical Professional
- First aid 1 CPSC: Injury, First Aid Received by Non-Medical Professional
As each report says it, in short words; CPSC’s own words are under each.
The reports, as CPSC published them
Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.
Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.
CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.
-
Seen by a doctor or nurse Made May 11, 2026, sent to the company Jun 18, 2026, published by CPSC Jul 7, 2026
The product, in the report: InMotion V14 Adventure electric unicycle 50s Serial: A0311851800217C0
CPSC Office of Compliance and Field Operations,
I am reporting a substantial product hazard under 15 U.S.C. Section 2064 and requesting investigation of manufacturer non-compliance with Section 15(b) reporting obligations.
INCIDENT SUMMARY
On December 13, 2025, at approximately 40 mph 0.3 miles from my home during normal operation, my InMotion V14 Adventure electric unicycle 50s (Serial: A0311851800217C0, Activated: 2025-05-08, Mileage: approximately 1,292 miles) experienced a sudden, complete loss of motor stabilization without tilt-back, audible warning, or pre-failure degradation. The controller ceased providing stabilization instantaneously, resulting in a high-speed crash. The crash as seen in the video is only 0.3 miles from my home, yet as the images show below, it claims 1.6 miles which is what it would have been had I made it to the store and back home. Luckily it was my father behind me in the vehicle recording and he immediately brought me to the hospital as the injury images show, it would have been impossible for me to have rode another 1.3 miles after the crash.
INJURY: acute radius break and ulna requiring four-hour surgery, a titanium plate and eight screws, ongoing physical therapy, and pending hardware removal procedure due to massive loss of mobility. I am right-hand dominant and a sawmill owner. I am also an independent researcher in HCI-IC. I have six years of college for a ba in math(csci major specializing in robotics). I am 42 years old and this vehicle was my main means of transportation and only means of transportation to get to [REDACTED] over 12 miles away. My riding data reflect my daily use and not a joyride for thrills. My images of all seven months of my ride data show the hall sensor was silently failing indicated by the mph spikes beyond the 43 mph so called tiltback and beeping alarm you can hear and see was missing in the unedited video. Medical records available upon request. FAILURE MODE: Silent control-path failure - not envelope exceedance. Post-incident: left hall sensor read error present; device exhibited uncontrolled motor runaway to maximum RPM when powered. This indicates single-point control-path failure rather than designed fail-safe behavior (torque reduction, speed clamping, tilt-back, or degraded mode). MANUFACTURER RESPONSE - DOCUMENTED EVASION AND ENDANGERMENT I engaged InMotion customer support (Ticket: [REDACTED] / Request #[REDACTED]) beginning January 3, 2026, providing engineering failure report, video evidence, device photos, and firmware information. Critical timeline: January 6-7, 2026: InMotion technical team reviewed available materials (video, photos, cloud telemetry) and identified specific faulty hardware: Controller Assembly, HMI Board PCBA Assembly, and [REDACTED] Display Board. Replacement of these assemblies was advised to restore app connectivity and support further diagnostics. January 7-14, 2026: Despite having identified faulty boards, InMotion instructed me - while I was recovering from surgery to my dominant hand - to reassemble and power the device to upload logs. Upon powering the controller with all components connected, the wheel immediately accelerated to uncontrolled maximum RPM runaway. I was fortunate my young son was not in the path of the device. This was not a diagnostic step. This was energizing a known-faulty control system in a residential environment. I refused further physical handling of the device after this event. January 20, 2026: Without new technical evidence, InMotion pivoted to undetermined cause framing - either due to faulty internal component or pushing the EUC over its limits - and demanded I purchase a replacement controller to retrieve logs, despite: (a) prior identification of faulty components; (b) documented runaway behavior making the device unsafe to handle; (c) my surgical recovery status. January 30, 2026: One-time exception offer: purchase new V14 50S for 2,499 USD (standard market price). February 28, 2026: New narrative introduced: Our technical team reviewed the historical logs associated with the device and identified multiple instances of overspeed riding, including recorded overspeed warnings. This narrative omits the uncontrolled runaway triggered by their own instructions. It contradicts six months of conservative riding, video evidence, their January 7 hardware-fault determination, and the silent nature of the original cutout. March 4, 2026: Formal evidence preservation notice issued. InMotion refused to confirm preservation, refused corporate legal contact, and reiterated purchase discount offer. March 26, 2026: [REDACTED], Director of North America, initiated unsolicited P6 sales outreach - side-channel engagement after safety-incident escalation was refused. EVIDENCE OF DATA POSSESSION Through network traffic analysis of the InMotion [REDACTED] application ([REDACTED]), I documented continuous real-time telemetry upload to manufacturer-controlled cloud infrastructure ([REDACTED]) and [REDACTED] infrastructure ([REDACTED]). This contradicts InMotion’s repeated claims that post-incident log upload was impossible due to destroyed [REDACTED] connectivity. Approximately February 2026, InMotion implemented certificate pinning/hardening in the application, preventing further independent audit of data flows. A full application overhaul followed. These actions occurred after I cited federal regulatory reporting obligations and documented their data architecture. REQUESTED ACTION 1. Open defect investigation of InMotion V14 control-path architecture, specifically single-point failure modes resulting in instantaneous loss of stabilization without rider warning or agency. 2. Subpoena manufacturer records including: raw ride telemetry for SN A0311851800217C0; internal technical notes from January 6-7 review; communications authorizing withdrawal of hardware-fault determination; and records of any other V14 incidents involving silent cutout or control-path failure. 3. Investigate Section 15(b) non-compliance - InMotion had knowledge of hardware fault and catastrophic failure mode by January 7, 2026, yet failed to report to CPSC and instead pursued consumer-level containment. 4. Preserve third-party records - Notification to [REDACTED] of relevant data custody for SN A0311851800217C0 telemetry. 5. Investigate manufacturer instructions creating secondary hazard - InMotion directed a recovering surgical patient to re-energize a device they had identified as containing faulty control electronics, resulting in uncontrolled motor runaway in a residential environment, my oldest son was present. ATTACHED DOCUMENTATION - [REDACTED] export: Main correspondence thread (67 messages, Ticket [REDACTED]) - [REDACTED] export: Response/offer thread (16 messages, Request #[REDACTED]) - [REDACTED] export: Pending request thread (9 messages) - [REDACTED] export: [REDACTED] P6 outreach (March 26, 2026) - Network traffic analysis summary (TLS endpoints, [REDACTED] ingest, API architecture) Within the pdf’s should be the video link via [REDACTED}. - Incident video metadata and description I am available for interview, additional documentation, or technical clarification. I request confirmation of report receipt and assigned investigation number. Respectfully, [REDACTED]
- Model
- V14
- Serial number
- A0311851800217C0
- Where
- Woodworth, Louisiana: Home/
Apartment/ Condominium - Who was involved
- Age 42, Unspecified
- The reporter’s relation to them
- Self
- As this report names them
- Brand InMotion, made or sold by InMotion LLC
- How badly, in CPSC’s words
- Injury, Seen by Medical Professional
-
First aid Made Apr 15, 2026, sent to the company Apr 17, 2026, published by CPSC May 1, 2026
The product, in the report: Electric self-balancing unicycle designed for recreational use, primarily marketed for beginners and children. The product operates using a single motorized wheel with dynamic balance control. It includes audible warning alerts and tilt-back mechanisms intended to prevent unsafe riding conditions. The device is battery powered and controlled via a mobile application. At the time of the incident, the battery level was approximately 50 percent and the device was functioning normally prior to the sudden shutdown. A critical safety concern is that under certain conditions, the device can abruptly shut down while in motion, which immediately removes balancing capability and results in a fall.
Product: INMOTION E20 Electric Unicycle An abrupt shutdown occurred while my 8 year old son was riding the device on a slight downhill residential street. Prior to the shutdown, the device emitted warning beeps. However, before the rider had sufficient time to safely decelerate, the unit shut down completely. Because this is a self balancing device, the sudden loss of power resulted in an immediate and unavoidable loss of balance, causing a fall and physical injury. The device had sufficient battery at the time, approximately 50 percent, and there were no modifications or abnormal usage conditions beyond normal residential riding. The incident was witnessed by two children, and photos and app data were captured immediately afterward without any modification to the device. Manufacturer Response: The manufacturer reviewed diagnostic logs and stated in writing that abrupt shutdown under certain conditions such as overload or overspeed is expected behavior and part of the system protection logic. Safety Concern: For a self balancing device, an abrupt shutdown directly causes a fall and creates a foreseeable injury risk. The warning system did not provide sufficient time or margin for safe recovery before shutdown. This raises concern that the product design allows a failure mode where rider injury is unavoidable. I am reporting this as a potential product safety hazard that may warrant further investigation and review.
- Model
- E20
- Serial number
- A14219C100009197
- Bought from
- InMotion Official Website
- Bought
- Jan 2, 2026
- Where
- Irvine, California: Street or Highway
- Who was involved
- Age 8, Male
- The reporter’s relation to them
- My Child
- As this report names them
- Brand INMOTION, made or sold by InMotion LLC
- How badly, in CPSC’s words
- Injury, First Aid Received by Non-Medical Professional
-
Emergency room Made Jul 17, 2024, sent to the company Jul 22, 2024, published by CPSC Aug 5, 2024
The product, in the report: Inmotion V5F electric unicycle at https://store.inmotionworld.com/products/inmotion-v5f?_gl=1*drc7pp*_up*MQ..&gclid=CjwKCAjw1920BhA3EiwAJT3lSUzBN-pq5ZLT15V8HXAgKjpdMOBJGqFRZ3r-_aA1Is8zJu_6S5ejNBoCHh4QAvD_BwE
On Sunday 6/23/2024 I was riding the Inmotion V5F electric unicycle at full speed when wheel suddenly powered off causing me to go sliding face first on the asphalt and causing me to go to hospital with serious injuries.
- Model
- V5F
- Serial number
- 17916A5CD1DA0055
- Bought from
- https:/
/ store.inmotionworld.com/ products/ inmotion- - Bought
- Jan 27, 2024
- Where
- San Angelo, Texas: Street or Highway
- Who was involved
- Age 69, Male
- The reporter’s relation to them
- Self
- As this report names them
- Brand Inmotion, made or sold by Hong Kong Lemotion Co. Ltd.
- How badly, in CPSC’s words
- Injury, Emergency Department Treatment Received
CPSC’s disclaimer
Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.
Word for word, from the disclaimer in CPSC’s export.
Sources
Sources
-
U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.
Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.
Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.