1 report to CPSC, the latest made Sep 23, 2021. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Sep 23, 2021the latest report was made
  • Sep 23, 2021the earliest
  • 0with the company’s comments
Brand
Blichmann
Maker
Blichmann Engineering LLCMakers, importers or sellers, as the reports name them
Product
Pressure cookers and cannersCPSC’s product type: Pressure Cookers or Canners (code 412), in Kitchen: Appliances

By month

1 report from October 2020 to September 2021; the most in September 2021, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
September 20211

How badly anyone was hurt

  • Emergency room 1 CPSC: Injury, Emergency Department Treatment Received

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. Emergency room

    Made Sep 23, 2021, sent to the company Sep 27, 2021, published by CPSC Oct 12, 2021

    The product, in the report: tri-clamp Blichmann spunding valve

    I have owned and used a [REDACTED] unitank beer fermenter for 2 1/2 years.

    I have probably brewed 30 to 40 five gallon batches in my unitank since receiving in January 2019. Around five or six of those have been pressure fermentations (the [REDACTED] is “rated” up to 15 psi according to the manufacturer). A few weeks back, it was my intent to brew a beer in the fermenter and to ferment at 10 psi. I use a tri-clamp Blichmann spunding valve to control psi.

    I sanitized the [REDACTED] placed all connections and lid on the fermenter, and started to pressurize with the spunding valve by keeping it full open at first, and closing the valve until it released CO2 at 10 psi. Never got there. At 9 PSI the band clamp closure failed, the lid exploded off and cracked my knuckle severing two tendons. These severed tendons required orthopedic surgery 10 days later to reattach. I just thank God the lid did not hit me in the face or head.

    Where
    Wheeling, West Virginia: Home/Apartment/Condominium
    Who was involved
    Age 57, Unknown
    The reporter’s relation to them
    Self
    As this report names them
    Brand Blichmann, made or sold by Blichmann Engineering LLC
    Reports CPSC links to it
    20210921-273DA-2147360448
    How badly, in CPSC’s words
    Injury, Emergency Department Treatment Received

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Pressure cookers and canners

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.