1 report to CPSC, the latest made Aug 29, 2023. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Aug 29, 2023the latest report was made
  • Aug 29, 2023the earliest
  • 1with the company’s comments
Brand
Murray (Siemens)
Maker
Siemens Industr Inc.Makers, importers or sellers, as the reports name them
Product
Breaker panels, circuit breakers and fusesIncluding GFCIsCPSC’s product type: Panelboards, Circuit Breakers, Gfci”s, or Fuses (code 4063), in Home Maintenance and Structures: Electrical Systems

By month

1 report from September 2022 to August 2023; the most in August 2023, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
August 20231

How badly anyone was hurt

  • No incident, no one hurt 1 CPSC: No Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No incident, no one hurt

    Made Aug 29, 2023, sent to the company Sep 6, 2023, published by CPSC Sep 20, 2023

    The product, in the report: Circuit breaker and load center that electrical contractor supplied and installed.

    As I was opening and closing circuit breakers in our house’s panel to try to find which one the dishwasher was on, when I closed one it made a buzzing/arcing noise. I turned it off again and pulled the breaker from the panel to investigate. Its contacts were pitted and there was loose metal pieces inside its case. Our electrical panel was upgraded in 2015 from 100 to 200 amps. It’s a Murray (Siemens) MP120 breaker in a Murray LC3040B1200 Load Center. No injuries, but if I hadn’t heard the arcing and the breaker was left on, this could have led to smoke and/or possibly a fire. I definitely have concerns about all of the other breakers in the panel.

    Model
    MP120 in LC3040B1200
    Where
    Webster Groves, Missouri: Home/Apartment/Condominium
    Who was involved
    Age 63, Unspecified
    The reporter’s relation to them
    Self
    As this report names them
    Brand Murray (Siemens), made or sold by Siemens Industr Inc.
    How badly, in CPSC’s words
    No Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Breaker panels, circuit breakers and fuses

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.