I-T-E (now Siemens) Indoor Load Center E0408ML1125F/S Type 1 breaker panels, circuit breakers and fuses

1 report to CPSC, the latest made Nov 12, 2014. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Nov 12, 2014the latest report was made
  • Nov 12, 2014the earliest
  • 0with the company’s comments
Brand
I-T-E (now Siemens) Indoor Load Center E0408ML1125F/S Type 1
Maker
SIEMENS INDUSTRY INCMakers, importers or sellers, as the reports name them
Product
Breaker panels, circuit breakers and fusesIncluding GFCIsCPSC’s product type: Panelboards, Circuit Breakers, Gfci”s, or Fuses (code 4063), in Home Maintenance and Structures: Electrical Systems

By month

1 report from December 2013 to November 2014; the most in November 2014, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
November 20141

How badly anyone was hurt

  • No one hurt 1 CPSC: Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No one hurt

    Made Nov 12, 2014, sent to the company Nov 24, 2014, published by CPSC Dec 9, 2014

    The product, in the report: Electrical circuit breaker or distribution bus failure in I-T-E (now owned by Siemens) 2-pole 240V load center, Unit manufactured in March, 1986- same unit was recalled with manufacturing dates of Aug-Oct of 1986. Unit fed 240V/ twin 50Amp circuits to electrical resistance heater coils in forced-air heat pump HVAC system. (electrical resistance heat used as “back-up” heat source to HVAC system) Circuit breakers within unit evidenced thermal fatigue/ expansion of metal clip-to load bus and resulted in electrical arcing to center load bus; circuit breaker failed to interrupt circuit, which resulted in overheating and eventual small electrical fire contained within the load center and internal circuit breakers. The ITE distribution load center unit had a date code of C1886 (Mar 18 1986) The Siemens 240V 50A circuit breakers date code is 07/99 Affected Unit: I-T-E Indoor Load Center E0408ML1125F/S-2 Manufactured date: C1886 (March 18, 1986) Affected Circuit Breakers: Siemens Type QP 50 Amp 240V model Q250; mfr date 07/99 Original Recall published by CSPC, Release # 88-0091 Affected units are specified as having date codes as: - H2586-H3186 (H = August, days 25 through 31, 86 = year) - J0186-J3086 (J = September, days I through 30, 86 = year) - K0186-K2486 (K = October, days I through 24, 86 = year) Affected Circuit Breakers: Siemens Type QP 50 Amp 240V model Q250; mfr date 07/99 Unit fed 240V/ twin 50Amp circuits to electrical resistance heater coils in forced-air heat pump HVAC system. (electrical resistance heat used as “back-up” heat source to HVAC system)

    Electrical circuit breaker or distribution bus failure in I-T-E (now owned by Siemens) 2-pole 240V load center, Unit manufactured in March, 1986- same unit was recalled with manufacturing dates of Aug-Oct of 1986.

    Unit fed 240V/ twin 50Amp circuits to electrical resistance heater coils in forced-air heat pump HVAC system. (electrical resistance heat used as “back-up” heat source to HVAC system)

    Circuit breakers within unit evidenced thermal fatigue/ expansion of metal clip-to load bus and resulted in electrical arcing to center load bus; circuit breaker failed to interrupt circuit, which resulted in overheating and eventual small electrical fire contained within the load center and internal circuit breakers.

    The ITE distribution load center unit had a date code of C1886 (Mar 18 1986) The Siemens 240V 50A circuit breakers date code is 07/99

    Affected Unit: I-T-E Indoor Load Center E0408ML1125F/S-2 Manufactured date: C1886 (March 18, 1986)

    Affected Circuit Breakers: Siemens Type QP 50 Amp 240V model Q250; mfr date 07/99

    Original Recall published by CSPC, Relase # 88-0091 Affected units are specified as having date codes as: - H2586-H3186 (H = August, days 25 through 31, 86 = year) - J0186-J3086 (J = September, days I through 30, 86 = year) - K0186-K2486 (K = October, days I through 24, 86 = year)

    Affected Circuit Breakers: Siemens Type QP 50 Amp 240V model Q250; mfr date 07/99

    Unit fed 240V/ twin 50Amp circuits to electrical resistance heater coils in forced-air heat pump HVAC system. (electrical resistance heat used as “back-up” heat source to HVAC system)

    Model
    E0408ML1125F/S
    UPC
    N/A
    Serial number
    N/A
    Bought
    Jun 7, 1986
    Where
    Madison, Alabama: Home/Apartment/Condominium
    Who was involved
    Age 43, Male
    The reporter’s relation to them
    Self
    As this report names them
    Brand I-T-E (now Siemens) Indoor Load Center E0408ML1125F/S Type 1, made or sold by SIEMENS INDUSTRY INC
    How badly, in CPSC’s words
    Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Breaker panels, circuit breakers and fuses

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.