Hearth Record

Back to Electric wiring

Crucial Power Systems electric wiring

1 report to CPSC, the latest made Dec 17, 2019. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Dec 17, 2019the latest report was made
  • Dec 17, 2019the earliest
  • 1with the company’s comments
Brand
Crucial Power Systems
Maker
Crucial Power ProductsMakers, importers or sellers, as the reports name them
Product
Electric wiringNot panel boards or outletsCPSC’s product type: Electric Wire or Wiring Systems (Excl Panelboards Recept (code 4062), in Home Maintenance and Structures: Electrical Systems

By month

1 report from January 2019 to December 2019; the most in December 2019, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
December 20191

How badly anyone was hurt

  • No one hurt 1 CPSC: Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No one hurt

    Made Dec 17, 2019, sent to the company Feb 4, 2020, published by CPSC Mar 25, 2020

    The product, in the report: Crucial Power Systems - Emergency Power System

    Crucial Power Systems Model ES1.5 A0100 N1-S S/N ES1562 This is an emergency lighting system designed to provide emergency egress lighting in the event of a utility power failure. The equipment consists of a power inverter, controller, touch screen control/monitor and batteries contained in a cabinet. The system uses one 120V AC circuit for input power and distributes output power to up to six 120V circuits. In the event of a utility power failure the system is designed to provide un-interrupted output power for egress lighting for a minimum of 90 minutes to be in compliance with current life safety codes. This particular system failed recently and shutdown output power to the egress lighting throughout the building. The lights were out until an electrician got to the site and temporarily bypassed the system and directly connected the loads to the line feed. Under certain circumstances this could be a hazardous situation. The building egress path was completely in the dark. The system should either fail to “lights on” or be provided with a bypass switch as a standard feature. The bypass switch is offered as an option.

    Model
    ES1.5A0100N1-S
    Serial number
    ES1562
    Where
    Charlotte CH, Virginia: Other Public Property/Office
    Who was involved
    Male
    The reporter’s relation to them
    Unspecified
    As this report names them
    Brand Crucial Power Systems, made or sold by Crucial Power Products
    How badly, in CPSC’s words
    Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Electric wiring

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.