Crucial Power Systems electric wiring
1 report to CPSC, the latest made Dec 17, 2019. A report isn’t a recall.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.
At a glance
From SaferProducts.gov, released Oct 25, 2026.
- 1report to CPSC
- Dec 17, 2019the latest report was made
- Dec 17, 2019the earliest
- 1with the company’s comments
- Brand
- Crucial Power Systems
- Maker
- Crucial Power ProductsMakers, importers or sellers, as the reports name them
- Product
- Electric wiringNot panel boards or outletsCPSC’s product type: Electric Wire or Wiring Systems (Excl Panelboards Recept (code 4062), in Home Maintenance and Structures: Electrical Systems
By month
The numbers, as a table
| Month | Reports |
|---|---|
| December 2019 | 1 |
How badly anyone was hurt
- No one hurt 1 CPSC: Incident, No Injury
As each report says it, in short words; CPSC’s own words are under each.
The reports, as CPSC published them
Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.
Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.
CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.
-
No one hurt Made Dec 17, 2019, sent to the company Feb 4, 2020, published by CPSC Mar 25, 2020
The product, in the report: Crucial Power Systems - Emergency Power System
Crucial Power Systems Model ES1.5 A0100 N1-S S/N ES1562 This is an emergency lighting system designed to provide emergency egress lighting in the event of a utility power failure. The equipment consists of a power inverter, controller, touch screen control/monitor and batteries contained in a cabinet. The system uses one 120V AC circuit for input power and distributes output power to up to six 120V circuits. In the event of a utility power failure the system is designed to provide un-interrupted output power for egress lighting for a minimum of 90 minutes to be in compliance with current life safety codes. This particular system failed recently and shutdown output power to the egress lighting throughout the building. The lights were out until an electrician got to the site and temporarily bypassed the system and directly connected the loads to the line feed. Under certain circumstances this could be a hazardous situation. The building egress path was completely in the dark. The system should either fail to “lights on” or be provided with a bypass switch as a standard feature. The bypass switch is offered as an option.
- Model
- ES1.5A0100N1-S
- Serial number
- ES1562
- Where
- Charlotte CH, Virginia: Other Public Property/
Office - Who was involved
- Male
- The reporter’s relation to them
- Unspecified
- As this report names them
- Brand Crucial Power Systems, made or sold by Crucial Power Products
- How badly, in CPSC’s words
- Incident, No Injury
CPSC’s disclaimer
Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.
Word for word, from the disclaimer in CPSC’s export.
Sources
Sources
-
U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.
Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.
Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.