Hearth Record

Back to Electric wiring

Cerrowire CerroMax electric wiring

1 report to CPSC, the latest made Dec 16, 2025. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Dec 16, 2025the latest report was made
  • Dec 16, 2025the earliest
  • 0with the company’s comments
Brand
Cerrowire CerroMax
Maker
CERRO WIRE AND CABLE CO., INC.Makers, importers or sellers, as the reports name them
Product
Electric wiringNot panel boards or outletsCPSC’s product type: Electric Wire or Wiring Systems (Excl Panelboards Recept (code 4062), in Home Maintenance and Structures: Electrical Systems

By month

1 report from January 2025 to December 2025; the most in December 2025, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
December 20251

How badly anyone was hurt

  • No incident, no one hurt 1 CPSC: No Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No incident, no one hurt

    Made Dec 16, 2025, sent to the company Dec 22, 2025, published by CPSC Jan 9, 2026

    The product, in the report: 3 rolls at 250 ft each of Cerrowire 12/2 NM-B (Yellow Jacket) BATCH CODE: 7/30/2025 | at 2150 J5 BTS

    During the rough-in electrical phase of a total-loss home reconstruction, a severe manufacturing defect was discovered in Cerrowire 12/2 NM-B made on 7/30/2025. The defect consists of a continuous longitudinal slit (lengthwise cut) in the insulation of the neutral (white) conductor. Hazard Description: Latent Nature: The defect is hidden beneath the outer yellow jacket of the cable. It is not visible to the naked eye during a standard “pull” or installation. Failure Mechanism: When the outer jacket is stripped and the neutral wire is bent or manipulated (as required for box termination), the slit in the insulation “pops” open, exposing the bare copper conductor. Imminent Risk: This creates an immediate risk of electrical arcing and fire. Because the insulation is breached along the entire 750-foot run, the hazard exists behind the walls where it cannot be monitored

    Model
    CerroMax with SLiPWire 12/2 NM-B (Yellow Jacket) M
    UPC
    See receipt
    Serial number
    Home Depot recipt00021612-2 NM 250 A) 12-2 NM /G 2
    Bought from
    Home Depot/ Farmington Hills
    Bought
    Sep 10, 2025
    Where
    Livonia, Michigan: Home/Apartment/Condominium
    Who was involved
    Male
    The reporter’s relation to them
    Self
    As this report names them
    Brand Cerrowire CerroMax, made or sold by CERRO WIRE AND CABLE CO., INC.
    How badly, in CPSC’s words
    No Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Electric wiring

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.