1 report to CPSC, the latest made Jul 21, 2020. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Jul 21, 2020the latest report was made
  • Jul 21, 2020the earliest
  • 1with the company’s comments
Brand
Coleman
Maker
The Coleman Company, Inc.Makers, importers or sellers, as the reports name them
Product
Air conditionersCPSC’s product type: Air Conditioners (code 381), in Home Maintenance and Structures: Heating, Ventilation & Air Conditioning

By month

1 report from August 2019 to July 2020; the most in July 2020, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
July 20201

How badly anyone was hurt

  • No one hurt 1 CPSC: Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No one hurt

    Made Jul 21, 2020, sent to the company Oct 26, 2020, published by CPSC Oct 5, 2020

    The product, in the report: A/C Adapter

    This is an A/C adapter designed to specifically connect to a thermal electric cooler, that is made by this same manufacturer. The A/C adapter has a transformer on the plug that is attached to the unit. When the adapter is plugged into the wall outlet and operated, the transformer gets extremely hot. The consumer estimates that the excessive heat occurs within 15 – 20 minutes of use.

    The consumer used it one day and it damaged his wall outlet so severely that he had to replace the outlet. He believes that the outlet’s terminals heated up and shrunk back down. This affected the wires inside the outlet, which prevented them from working properly and caused them to quit working.

    7/21/2020: The consumer called the manufacturer, but their rep. (name unavailable) did not understand his concerns or take them as seriously as he thought that they should have.

    The transformer itself is between the A/C plug and the 12 volt adapter. On his unit, the adapter is connected directly to the plug and acts as a heat-sync.

    Model
    G602-1250
    Serial number
    1912-0000330
    Bought from
    Amazon.com
    Bought
    Jul 13, 2020
    Where
    Plainview, New York: Home/Apartment/Condominium
    Who was involved
    Male
    The reporter’s relation to them
    Unspecified
    As this report names them
    Brand Coleman, made or sold by The Coleman Company, Inc.
    How badly, in CPSC’s words
    Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Air conditioners

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.