Hearth Record

Back to Ductwork for heating or cooling systems

Honeywell ductwork for heating or cooling systems

1 report to CPSC, the latest made Mar 27, 2012. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Mar 27, 2012the latest report was made
  • Mar 27, 2012the earliest
  • 0with the company’s comments
Brand
Honeywell
Maker
HONEYWELL INTERNATIONAL HEADQUARTERSMakers, importers or sellers, as the reports name them
Product
Ductwork for heating or cooling systemsCPSC’s product type: Ductwork For Heating or Cooling Systems (code 371), in Home Maintenance and Structures: Heating, Ventilation & Air Conditioning

By month

1 report from April 2011 to March 2012; the most in March 2012, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
March 20121

How badly anyone was hurt

  • No one hurt 1 CPSC: Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No one hurt

    Made Mar 27, 2012, sent to the company Apr 4, 2012, published by CPSC Apr 18, 2012

    The product, in the report: Honeywell Fast Acting, Two Position Actuators Model: MS4120F 1006 - spring return, direct coupled actuators for on/off damper control. Designed to operate in smoke control systems requiring Underwriter’s Laboratories Inc UL555S ratings up to 350 degrees F

    Honeywell MS4120F 1006 actuators were being used in the Lincoln Tower fire suppression system in Bellevue, WA. During an annual test for the fire department, a majority of the actuators that were supposed to fail open to allow relief air out of the building, failed to operate properly. Out of 9 actuators tested, 6 exhibited the same failure. The failure was occurring at the main gear shaft. This metal shaft was intended to be mechanically pressed into the spring case and become displaced and loose. The shaft had been only partially pressed into the spring case with allowed the shaft to ‘rock’ in the improper joint which eventually lead to the shaft coming free. Once the shaft joint was compromised, the interior cover bore the eccentric loading from the gear shaft which it was not designed to withstand. The gear cover then broke loose as well, causing the gears to move out of place, grind on each other and eventually causing the gears to become stuck and unable to move.

    Model
    MS4120F 1006
    Where
    Bellevue, Washington: Other Public Property/Office
    Who was involved
    Unspecified
    The reporter’s relation to them
    Unspecified
    As this report names them
    Brand Honeywell, made or sold by HONEYWELL INTERNATIONAL HEADQUARTERS
    How badly, in CPSC’s words
    Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Ductwork for heating or cooling systems

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.