ClimateMaster heat pumps
1 report to CPSC, the latest made Aug 26, 2020. A report isn’t a recall.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.
At a glance
From SaferProducts.gov, released Oct 25, 2026.
- 1report to CPSC
- Aug 26, 2020the latest report was made
- Aug 26, 2020the earliest
- 0with the company’s comments
- Brand
- ClimateMaster
- Maker
- CLIMATE MASTER, INC.Makers, importers or sellers, as the reports name them
- Product
- Heat pumpsCPSC’s product type: Heat Pumps (code 365), in Home Maintenance and Structures: Heating, Ventilation & Air Conditioning
By month
The numbers, as a table
| Month | Reports |
|---|---|
| August 2020 | 1 |
How badly anyone was hurt
- No one hurt 1 CPSC: Incident, No Injury
As each report says it, in short words; CPSC’s own words are under each.
The reports, as CPSC published them
Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.
Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.
CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.
-
No one hurt Made Aug 26, 2020, sent to the company Sep 30, 2020, published by CPSC Nov 10, 2020
The product, in the report: ClimateMaster geothermal heat pump split system condenser unit Model TES049BGD02ANNS
Fire hazard. ClimateMaster model TES049 geothermal heat pump wiring shorted out during normal operation in the early morning of August 22, 2020. The wiring harness was positioned close to the copper refrigerant line going into the compressor. Electric sparks from the wiring arced against the copper refrigerant line causing a pinhole leak in the copper line. R410A refrigerant escaped and filled the garage, where the heat pump was located, with freon gas. Prior to this incident, the heat pump was experiencing false high pressure/high temperature faults in the water loop system causing the unit to shutdown prematurely. The house could have caught on fire while the occupants were sleeping. This unit needs to be recalled immediately.
- Model
- TES049BGD02ANNS
- Serial number
- 194211033
- Bought from
- Gildersleeve Geothermal Heating/
Cooling & Well Drilling - Bought
- Nov 14, 2019
- Where
- Virginia Beac, Unspecified: Home/
Apartment/ Condominium - Who was involved
- Unknown
- The reporter’s relation to them
- Unspecified
- As this report names them
- Brand ClimateMaster, made or sold by CLIMATE MASTER, INC.
- How badly, in CPSC’s words
- Incident, No Injury
CPSC’s disclaimer
Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.
Word for word, from the disclaimer in CPSC’s export.
Sources
Sources
-
U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.
Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.
Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.