Hearth Record

Back to Portable electric heaters

Everstar portable electric heaters

1 report to CPSC, the latest made Feb 4, 2021. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Feb 4, 2021the latest report was made
  • Feb 4, 2021the earliest
  • 0with the company’s comments
Brand
Everstar
Maker
SIENHUA GROUP (NORTH AMERICA) INC.Makers, importers or sellers, as the reports name them
Product
Portable electric heatersCPSC’s product type: Portable Electric Heaters (code 348), in Home Maintenance and Structures: Heating, Ventilation & Air Conditioning

By month

1 report from March 2020 to February 2021; the most in February 2021, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
February 20211

How badly anyone was hurt

  • No one hurt 1 CPSC: Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No one hurt

    Made Feb 4, 2021, sent to the company Mar 3, 2021, published by CPSC Mar 17, 2021

    The product, in the report: Everstar Electric space heater, 1500W, black and grey. Model HPQ15-M UPC 877697-003153

    A tall Everstar electric space heater, Model HPQ15-M, 1500W, was found to keep running even when tipped over, creating a fire hazard. I took it apart and investigated, and found that the switch (brand Jinhe, model XCK-1) that turns the heater off when the unit tips over was faulty; the switch fails to open the circuit even when actuated. The heater was being used by an adult. It was being used normally when it was tipped over. No fire or injuries occurred, but a carpet fire could have been ignited. It’s a clear problem that the first thing on the unit to fail was the only safety feature, because we could have gone on using it for years, risking a fire. There was also melted plastic near the switch, indicating overheating of the switch. Although it is an older unit, I recommend CPSC contact the manufacturer. I have photos if you would like them.

    Model
    HPQ15-M
    UPC
    877697-003153
    Where
    TAKOMA PARK, Maryland: Home/Apartment/Condominium
    Who was involved
    Unknown
    The reporter’s relation to them
    Unspecified
    As this report names them
    Brand Everstar, made or sold by SIENHUA GROUP (NORTH AMERICA) INC.
    How badly, in CPSC’s words
    Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Portable electric heaters

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.