From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Aug 20, 2026the latest report was made
  • Aug 20, 2026the earliest
  • 0with the company’s comments
Brand
Makevivi
Maker
MAKEVIVIMakers, importers or sellers, as the reports name them
Product
ThermostatsFor heating or cooling systemsCPSC’s product type: Thermostats (For Heating or Cooling Systems) (code 340), in Home Maintenance and Structures: Heating, Ventilation & Air Conditioning

By month

1 report from September 2025 to August 2026; the most in August 2026, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
August 20261

How badly anyone was hurt

  • No incident, no one hurt 1 CPSC: No Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No incident, no one hurt

    Made Aug 20, 2026, sent to the company Aug 26, 2026, published by CPSC Sep 11, 2026

    The product, in the report: The product is a thermostat switch intended for residential exhaust fans. It has a steel enclosure, 5.6”L x 3.2”W x 1.8”H, painted gray, and weighs about 8 oz.

    This product is a thermostatic switch intended for residential exhaust fans. Before installing it, I tested the outlet of the product for correct internal wiring using a plug-in GFCI tester (Intertek 3080912). The tester indicated an open ground. Being a competent electrician, I removed the cover of the product to repair the fault. Upon further examination, I discovered two other serious design flaws: The hot and neutral wires are reversed at the product’s outlet, and worse, the internal relay switches the neutral instead of the hot. This means that the neural of the receptacle is hot continuously, regardless of the state of the relay. So a ground fault in any device plugged into this product will not trip a breaker as safety ground is supposed to do, but instead will cause the frame of the device and any metal it’s in contact with to be hot. This presents a shock and fire hazard.

    Model
    none shown
    UPC
    none shown
    Serial number
    none shown
    Bought from
    Amazon.com
    Bought
    Jul 1, 2026
    Where
    Cincinnati, Ohio: Home/Apartment/Condominium
    Who was involved
    Age 68, Male
    The reporter’s relation to them
    Self
    As this report names them
    Brand Makevivi, made or sold by MAKEVIVI
    How badly, in CPSC’s words
    No Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Thermostats

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.