Makevivi thermostats
1 report to CPSC, the latest made Aug 20, 2026. A report isn’t a recall.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.
At a glance
From SaferProducts.gov, released Oct 25, 2026.
- 1report to CPSC
- Aug 20, 2026the latest report was made
- Aug 20, 2026the earliest
- 0with the company’s comments
- Brand
- Makevivi
- Maker
- MAKEVIVIMakers, importers or sellers, as the reports name them
- Product
- ThermostatsFor heating or cooling systemsCPSC’s product type: Thermostats (For Heating or Cooling Systems) (code 340), in Home Maintenance and Structures: Heating, Ventilation & Air Conditioning
By month
The numbers, as a table
| Month | Reports |
|---|---|
| August 2026 | 1 |
How badly anyone was hurt
- No incident, no one hurt 1 CPSC: No Incident, No Injury
As each report says it, in short words; CPSC’s own words are under each.
The reports, as CPSC published them
Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.
Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.
CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.
-
No incident, no one hurt Made Aug 20, 2026, sent to the company Aug 26, 2026, published by CPSC Sep 11, 2026
The product, in the report: The product is a thermostat switch intended for residential exhaust fans. It has a steel enclosure, 5.6”L x 3.2”W x 1.8”H, painted gray, and weighs about 8 oz.
This product is a thermostatic switch intended for residential exhaust fans. Before installing it, I tested the outlet of the product for correct internal wiring using a plug-in GFCI tester (Intertek 3080912). The tester indicated an open ground. Being a competent electrician, I removed the cover of the product to repair the fault. Upon further examination, I discovered two other serious design flaws: The hot and neutral wires are reversed at the product’s outlet, and worse, the internal relay switches the neutral instead of the hot. This means that the neural of the receptacle is hot continuously, regardless of the state of the relay. So a ground fault in any device plugged into this product will not trip a breaker as safety ground is supposed to do, but instead will cause the frame of the device and any metal it’s in contact with to be hot. This presents a shock and fire hazard.
- Model
- none shown
- UPC
- none shown
- Serial number
- none shown
- Bought from
- Amazon.com
- Bought
- Jul 1, 2026
- Where
- Cincinnati, Ohio: Home/
Apartment/ Condominium - Who was involved
- Age 68, Male
- The reporter’s relation to them
- Self
- As this report names them
- Brand Makevivi, made or sold by MAKEVIVI
- How badly, in CPSC’s words
- No Incident, No Injury
CPSC’s disclaimer
Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.
Word for word, from the disclaimer in CPSC’s export.
Sources
Sources
-
U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.
Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.
Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.