1 report to CPSC, the latest made Jul 8, 2014. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Jul 8, 2014the latest report was made
  • Jul 8, 2014the earliest
  • 1with the company’s comments
Brand
Magnum II/Badger Fitness
Maker
Johnson Health Tech of North AmericaMakers, importers or sellers, as the reports name them
Product
Weight liftingThe activity, its clothing or equipmentCPSC’s product type: Weight Lifting (Activity, Apparel or Equipment) (code 3265), in Sports and Recreation: Track, Field & Exercise

By month

1 report from August 2013 to July 2014; the most in July 2014, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
July 20141

How badly anyone was hurt

  • No one hurt 1 CPSC: Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No one hurt

    Made Jul 8, 2014, sent to the company Jul 25, 2014, published by CPSC Aug 8, 2014

    The product, in the report: 10 degree Smith MAchine

    Matrix Fitness acquired Badger Fitness & earlier this year Matrix called me, asking what serial # did I have for the 10 degree Smith Machine. Upon providing them the serial #, Matrix sent 2 black spacer metal bars, instructing us to put them on the guide rods, at the bottom of each vertical guide rod. We did & while on vacation, week of June 9th or June 16th, 2014, a user doing a decline bench press experienced the lifting bar becoming unbalanced. When I returned, I put both machines out of order & brought the situation to the attention of Matrix. The Smith Machine has safety stops which latch onto safety pegs, located throughout the inner part of the frame on both sides. These safety stops are used by users to help the user restrict the range of motion, depending on the exercise they are doing. With the addition of the black spacer bars, the lowest safety pegs cannot be used & in this case when the user needed the lowest range of motion for a decline, the safety stops rested on top of the black spacer bar & the added weight hit one of the unlatched safety stops causing an unbalanced bar. I brought this to the attention of Matrix & was told to have the users use the safety stop, located above the black spacer bar. I asked them for instructions for this & was told that this would be outside the range of support. They would not provide safety instructions. I have 2 calls into supervisors, [REDACTED], spelled wrong. 800-818-6479, as of yet, not heard from either. I have voice mail and have sent email to editor of Athletic Business, [REDACTED]. Knowing that there is mechanical problem since Matrix added this black spacer bar, Club USA has theses 2 machines out of order & are waiting dialog with Matrix or information from this report.

    Serial number
    25157 & 25158
    Bought from
    KOS Fitness
    Where
    Littleton, Colorado: Place of Recreation or Sports
    Who was involved
    Unknown
    The reporter’s relation to them
    My Client, Patient, Student, Etc. (professional relationship)
    As this report names them
    Brand Magnum II/Badger Fitness, made or sold by Johnson Health Tech of North America
    How badly, in CPSC’s words
    Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Weight lifting

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.