Hearth Record

Back to Gas stoves and ovens

FOTILE gas stoves and ovens

1 report to CPSC, the latest made Jan 13, 2026. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Jan 13, 2026the latest report was made
  • Jan 13, 2026the earliest
  • 0with the company’s comments
Brand
FOTILE
Maker
FOTILE AMERICA LLCMakers, importers or sellers, as the reports name them
Product
Gas stoves and ovensCPSC’s product type: Gas Ranges or Ovens (code 279), in Kitchen: Appliances

By month

1 report from February 2025 to January 2026; the most in January 2026, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
January 20261

How badly anyone was hurt

  • No one hurt 1 CPSC: Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No one hurt

    Made Jan 13, 2026, sent to the company Jan 16, 2026, published by CPSC Feb 6, 2026

    The product, in the report: Gas cooktop (built-in), Fotile EPS series Fuel type: Natural Gas

    After approximately two years of normal household use, both burners on my Fotile EPS series gas cooktop began leaking gas at the same time.

    The burners ignite normally, but when the flame is reduced to a low setting, gas leakage becomes significant. When the flame is increased, the leakage appears reduced but does not fully stop. This behavior occurs on both burners simultaneously.

    I reported the issue to the manufacturer and repeatedly requested an on-site inspection by an authorized technician, but no actionable local service contact or scheduling option was provided. The manufacturer’s technical team conducted a remote assessment and stated that the issue might be related to deformation of burner-related components. Replacement parts for both burners were shipped without any on-site inspection. I was advised that self-repair with remote guidance is an acceptable option for gas-related issues.

    Because the gas leakage occurred on both burners at the same time, I was concerned that shared or upstream gas components might be involved. Without an on-site inspection by an authorized technician, I could not confirm that replacing individual burner parts would fully resolve the gas leakage or eliminate safety risk.

    To mitigate ongoing safety risk, I replaced the cooktop. No injuries occurred during the incident.

    Model
    GAG76202
    UPC
    Unknown
    Serial number
    1002001900407L60231108
    Bought from
    us.fotileglobal.com
    Bought
    Jan 26, 2024
    Where
    Houston, Texas: Home/Apartment/Condominium
    Who was involved
    Age 35, Unspecified
    The reporter’s relation to them
    Self
    As this report names them
    Brand FOTILE, made or sold by FOTILE AMERICA LLC
    How badly, in CPSC’s words
    Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Gas stoves and ovens

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.