1 report to CPSC, the latest made Nov 20, 2017. A report isn’t a recall.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.
At a glance
From SaferProducts.gov, released Oct 25, 2026.
- 1report to CPSC
- Nov 20, 2017the latest report was made
- Nov 20, 2017the earliest
- 0with the company’s comments
- Brand
- Follett
- Maker
- Follett LLCMakers, importers or sellers, as the reports name them
- Product
- Ice makersSeparate from refrigeratorsCPSC’s product type: Ice Makers (Separate From Refrigerators) (code 227), in Kitchen: Appliances
By month
The numbers, as a table
| Month | Reports |
|---|---|
| November 2017 | 1 |
How badly anyone was hurt
- No one hurt 1 CPSC: Incident, No Injury
As each report says it, in short words; CPSC’s own words are under each.
The reports, as CPSC published them
Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.
Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.
CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.
-
No one hurt Made Nov 20, 2017, sent to the company May 1, 2018, published by CPSC May 15, 2018
The product, in the report: Follett 2013 Ice Machine Model: 12HI 400 A
The Ice machine in the ICU started to smoke. The fire department and facilities management were notified. The Ice machine was taken out of service and the manufacturer was notified. No one was harmed and this did not disrupt patient care. The Follett representative was contacted and stated that due to the previous ice machine fire they investigated, they found an issue with the relay and were in process of a recall to replace these defective part. They started getting other facilities that were having the same issue. The root cause of the problem was that GE did not use enough copper wire in the windings of the relay when making the part, causing them to over heat and melt. The ICU Ice machine was replaced, and 3 other ice machines had the defective part replaced.
- Model
- 12HI 400 A
- Where
- Rochester, New York: Other Public Property/
Office - Who was involved
- Unspecified
- The reporter’s relation to them
- Unspecified
- As this report names them
- Brand Follett, made or sold by Follett LLC
- How badly, in CPSC’s words
- Incident, No Injury
CPSC’s disclaimer
Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.
Word for word, from the disclaimer in CPSC’s export.