Heatizon house repair and building materials
1 report to CPSC, the latest made Jan 13, 2018. A report isn’t a recall.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.
At a glance
From SaferProducts.gov, released Oct 25, 2026.
- 1report to CPSC
- Jan 13, 2018the latest report was made
- Jan 13, 2018the earliest
- 0with the company’s comments
- Brand
- Heatizon
- Maker
- HEATIZON SYSTEMMakers, importers or sellers, as the reports name them
- Product
- House repair and building materialsCPSC’s product type: House Repair or Construction Materials,nec (code 1876), in Home Maintenance and Structures: Building Materials & Home Structures
By month
The numbers, as a table
| Month | Reports |
|---|---|
| January 2018 | 1 |
How badly anyone was hurt
- No one hurt 1 CPSC: Incident, No Injury
As each report says it, in short words; CPSC’s own words are under each.
The reports, as CPSC published them
Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.
Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.
CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.
-
No one hurt Made Jan 13, 2018, sent to the company May 17, 2018, published by CPSC Jun 1, 2018
The product, in the report: a specialty roof deicing system with a heating element consisting of a bronze mesh installed underneath the shingles.
At 11:39 a.m. on April 13, 2015, a water flow alarm associated with the fire sprinkler system in the attic of the Fraser Holiday Inn Express initiated a call to the fire department. The fire department responded with the first units arriving on scene at 11:45 a.m. Upon arrival, the fire department observed fire in the roof/soffit area on the back side of the building. Sprinklers in the attic were containing fire spread, and the responding fire fighters were able to complete fire extinguishment. Fire, smoke, and water resulted in significant damage to the structure and contents. The Holiday Inn Express in Fraser had previously provided lodging under another name, but had recently been purchased and renovated, with renovations completed in early October 2014. The renovation project was executed by general contractor, Superior Builders, Inc. (Superior), with subcontractors Limon Electric Supply, Inc. (Limon Electric), Roofcraft, Inc., and others. The work included the removal of the existing ice- and snow-melt cables from the roof and replacement of the roof. A new ice- and snow-melt system was installed on the roof, under the shingles. The new ice- and snow-melt system was manufactured by Heatwave Systems, LLC, doing business as Heatizon Systems, and the system that was installed is designated as a ZMesh system. The ZMesh system was installed by the electrical contractor, Limon Electric, after which the shingles were installed by RoofCraft and their subcontractor, G&R Roofing. The ignition source in the area of origin was the ZMesh system. Photographs of the point of fire origin showed the presence of the ZMesh material in the area of origin. In addition, a distinctive oxidation pattern of concentric rings was seen on the sheet metal of the drip edge surrounding a nail hole in immediate proximity to the point of origin (see Figure 6). This concentric ring oxidation pattern is consistent with extreme heat being generated at the interface between the nail and the sheet metal. Thus, the burn patterns in and around the area of fire origin were consistent with the ZMesh system providing the energy of fire ignition. A detailed engineering analysis of the Zmesh system determined the product to be unreasonably dangerous.
- Model
- Zmesh
- Where
- Fraser, Colorado: Other
- Who was involved
- Male
- The reporter’s relation to them
- No Relationship
- As this report names them
- Brand Heatizon, made or sold by HEATIZON SYSTEM
- How badly, in CPSC’s words
- Incident, No Injury
CPSC’s disclaimer
Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.
Word for word, from the disclaimer in CPSC’s export.
Sources
Sources
-
U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.
Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.
Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.