Hearth Record

Back to Scaffolding

[REDACTED] OK5STAR [REDACTED] scaffolding

1 report to CPSC, the latest made Mar 13, 2024. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Mar 13, 2024the latest report was made
  • Mar 13, 2024the earliest
  • 0with the company’s comments
Brand
[REDACTED] OK5STAR [REDACTED]
Maker
Anji Belem Furniture Co.,LtdMakers, importers or sellers, as the reports name them
Product
ScaffoldingCPSC’s product type: Scaffolding (code 1816), in Yard & Garden: Outdoor Structures

By month

1 report from April 2023 to March 2024; the most in March 2024, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
March 20241

How badly anyone was hurt

  • Emergency room 1 CPSC: Injury, Emergency Department Treatment Received

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. Emergency room

    Made Mar 13, 2024, sent to the company Mar 19, 2024, published by CPSC Apr 2, 2024

    The product, in the report: 5-Inch Scaffolding Casters Wheel, with Dual Locking Brakes, Heavy Duty 440LBS Capacity per Wheel, Rubber Casters Square 1.25”

    A contractor was working on a scaffold when a newly replace 5-inch caster broke away. As a result, the contractor fell 4 feet from the ground causing bruised ribs and a broken rib to his right side. Further investigation revealed the caster was not properly weld between the stem and the top plate. The caster was improperly manufactured and could not sustain the recommended rating of 440lbs. The caster was in the lock position and no movement was conducted with the scaffold. While inspecting other casters, we noticed the newly purchased casters did not have an outside weld like other original casters. The contractor stated they purchased the castors from Amazon and the vendor is still to be determined. We recommended the vendor to conduct an inspection of all scaffolds to determine if they possess the new replacement caster. If so, they were to suspend operations of the scaffold until further notice.

    Model
    [REDACTED]
    UPC
    Unknown
    Serial number
    Unknown
    Where
    Fort Eisenhower, Georgia: Other Public Property/Office
    Who was involved
    Age 24, Male
    The reporter’s relation to them
    Unspecified
    As this report names them
    Brand [REDACTED] OK5STAR [REDACTED], made or sold by Anji Belem Furniture Co.,Ltd
    How badly, in CPSC’s words
    Injury, Emergency Department Treatment Received

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Scaffolding

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.