Hearth Record

Back to Pumps

Xylem pumps

1 report to CPSC, the latest made Mar 12, 2026. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Mar 12, 2026the latest report was made
  • Mar 12, 2026the earliest
  • 0with the company’s comments
Brand
Xylem
Maker
Xylem Inc.Makers, importers or sellers, as the reports name them
Product
PumpsCPSC’s product type: Pumps, Not Elsewhere Classified (code 1462), in Yard & Garden: Other

By month

1 report from April 2025 to March 2026; the most in March 2026, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
March 20261

How badly anyone was hurt

  • No one hurt 1 CPSC: Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No one hurt

    Made Mar 12, 2026, sent to the company Apr 24, 2026, published by CPSC May 8, 2026

    The product, in the report: Pump with electrocution hazard. Problem has been described previously here.

    I purchased a submersible pump for my well water supply to my home. The pump, manufactured by Xylem Corp. was part# 10HS05422C. I checked with my multimeter (I am a retired electrician) when I unboxed the pump and discovered that the metal enclosure on the upper section of the pump was not grounded. That is, there was no connection from this exposed housing to the green grounding wire supplied with the pump. This is an electrocution hazard. If one of the power wires to the pump was to rub onto this housing to a point where the insulation on the wire fails the metal housing would become live (energized) and someone reaching in the water to remove or service the pump would most likely be electrocuted (dead). There are other electrical failures that could have the same outcome. This situation is a violation of the National Electrical Code 250.134 which states that all exposed metal parts of an electrical device must be grounded. It also violates U.L. 778 section 18.2. The pump is a long cylinder, 4 in diameter, which has an exposed metal case around the motor (lower section) and an exposed metal case for the pump (upper section). The two sections are separated by a small plastic middle section (the water intake). This plastic part separates the two sections electrically. The green ground wire connects to the lower pump section housing as it should but because of the plastic section the metal case of the upper section is not grounded. This same construction is used by Xylem for other pumps in this series and I suspect other series as well. I initially submitted this report here around 1/28/2026 but I just learned from your staff that they have no record of it. I was given a case number then ([REDACTED]) but something went wrong apparently. I notified the manufacturer also at the end of January but have only heard that they have received the complaint but no report of any action they have taken. I also submitted a technical addendum to my initial report to you by email and I will do that again in hopes that you can connect it to my case. From my profess ional understanding of the issue with this pump, production and sales should be stopped and a warning and remedy should be issued to distributors. Recalls to consumers as well.

    Model
    10HS05422C
    UPC
    Unknown
    Serial number
    F2531440
    Bought from
    Irr Supply Co. Erie, PA
    Bought
    Jan 27, 2026
    Where
    North East, Pennsylvania: Home/Apartment/Condominium
    Who was involved
    Age 75, Unspecified
    The reporter’s relation to them
    Self
    As this report names them
    Brand Xylem, made or sold by Xylem Inc.
    How badly, in CPSC’s words
    Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Pumps

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.