Parts2o pumps
1 report to CPSC, the latest made Nov 23, 2013. A report isn’t a recall.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.
At a glance
From SaferProducts.gov, released Oct 25, 2026.
- 1report to CPSC
- Nov 23, 2013the latest report was made
- Nov 23, 2013the earliest
- 0with the company’s comments
- Brand
- Parts2o
- Maker
- Sta-Rite Industries, LLC (a Wisconsin Limited Liability CompMakers, importers or sellers, as the reports name them
- Product
- PumpsCPSC’s product type: Pumps, Not Elsewhere Classified (code 1462), in Yard & Garden: Other
By month
The numbers, as a table
| Month | Reports |
|---|---|
| November 2013 | 1 |
How badly anyone was hurt
- No one hurt 1 CPSC: Incident, No Injury
As each report says it, in short words; CPSC’s own words are under each.
The reports, as CPSC published them
Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.
Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.
CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.
-
No one hurt Made Nov 23, 2013, sent to the company Dec 3, 2013, published by CPSC Dec 17, 2013
The product, in the report: Well pressure swithh
Switch failed in the run position after 17 months. A year warranty on something that should last a but forever is not worth much. Pump was running full time. Had over 120 PSI in the system. The gauge was pegged I am glad that the weak link in my pluming was in a unfinished space near a drain and not the pressure tank or in a wall upstairs. (The previous switch lasted 23 years. It failed when the diaphragm devolved a small leak and caused corrosion on one of the contacts resulting in no electrical connection.) The cause of this switches failure is the part that rests against the diaphragm and transmits the force of the water pressure to the switch. It is a disk with two legs bent from the same piece of metal. Both of the legs are and has always be over bent. (>90 degrees) One is bent more than the other. This shows on the wear pattern of the contact points. Over time it the wear caused one of the legs to slid off it’s contact point. With the legs at opposite sides of the diaphragm and the disk not engineered to move parallel with out bot legs in contact little (well less than half) of the pressure was transferred to the switch and the pump would not shut off. With most manufacturing defects if there is one most likely there are more produced at the same time. It is all so possible it has been found and corrected by now.
- Model
- Type SK-2
- Bought from
- Homedepot
- Bought
- Jun 25, 2012
- Where
- Unspecified: Unspecified
- Who was involved
- Unspecified
- The reporter’s relation to them
- Self
- As this report names them
- Brand Parts2o, made or sold by Sta-Rite Industries, LLC (a Wisconsin Limited Liability Comp
- How badly, in CPSC’s words
- Incident, No Injury
CPSC’s disclaimer
Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.
Word for word, from the disclaimer in CPSC’s export.
Sources
Sources
-
U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.
Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.
Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.