General Electric other water heaters
2 reports to CPSC, the latest made Apr 20, 2019. A report isn’t a recall.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.
At a glance
From SaferProducts.gov, released Oct 25, 2026.
- 2reports to CPSC
- Apr 20, 2019the latest report was made
- Apr 11, 2019the earliest
- 0with the company’s comments
- Brand
- General Electric
- Maker
- GE Appliances, a Haier companyMakers, importers or sellers, as the reports name them
- Product
- Other water heatersCPSC’s product type: Other Water Heaters (code 133), in Home Maintenance and Structures: Plumbing & Bath
By month
The numbers, as a table
| Month | Reports |
|---|---|
| April 2019 | 2 |
How badly anyone was hurt
- No one hurt 2 CPSC: Incident, No Injury
As each report says it, in short words; CPSC’s own words are under each.
The reports, as CPSC published them
Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.
Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.
CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.
-
No one hurt Made Apr 20, 2019, sent to the company Apr 29, 2019, published by CPSC May 13, 2019
The product, in the report: General Electric Hybrid Water Heater
The hot water heater short circuited and melted the wires in the hot water heater. The insulation on the power wires melted before the circuit breaker tripped.
- Model
- GEH50DEEDSRB
- Serial number
- HD603569G
- Bought from
- Lowe’s, Georgia
- Bought
- Jan 1, 2015
- Where
- Kathleen, Georgia: Home/
Apartment/ Condominium - Who was involved
- Unknown
- The reporter’s relation to them
- Unspecified
- As this report names them
- Brand General Electric, made or sold by GE Appliances, a Haier company
- How badly, in CPSC’s words
- Incident, No Injury
-
No one hurt Made Apr 11, 2019, sent to the company Apr 26, 2019, published by CPSC May 10, 2019
The product, in the report: GE Geospring Hot Hybrid Hot Water Heater
This is for a GE Geosprint Heat Pump Hot Water Heater. The Clean Filter light is on and beeps, I cleaned the filter, attempted to reset the alert per instructions, but the light stays on and the beeping continues.
The problem is a leaking evaporator coil in the heat pump (top portion) of the water heater. Believe it or not, the evaporator coil may be freezing up due to low refrigerant levels, which triggers the filter alarm. GE knows all about this problem. A RECALL IS IN ORDER HERE. 410A refrigerant is leaking into my home is ANYTHING BUT SAFE!
- Model
- GEH50DEEDSRB
- Serial number
- TD606104G
- Bought from
- Lowes, Pennsylvania
- Bought
- Nov 11, 2014
- Where
- Saylorsburg, Pennsylvania: Home/
Apartment/ Condominium - Who was involved
- Unknown
- The reporter’s relation to them
- Unspecified
- As this report names them
- Brand General Electric, made or sold by GE Appliances, a Haier company
- How badly, in CPSC’s words
- Incident, No Injury
CPSC’s disclaimer
Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.
Word for word, from the disclaimer in CPSC’s export.
Sources
Sources
-
U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.
Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.
Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.