Hearth Record

Back to Scuba diving

Suunto scuba diving

1 report to CPSC, the latest made May 20, 2025. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • May 20, 2025the latest report was made
  • May 20, 2025the earliest
  • 0with the company’s comments
Brand
Suunto
Maker
SUUNTO OYMakers, importers or sellers, as the reports name them
Product
Scuba divingThe activity, its clothing or equipmentCPSC’s product type: Scuba Diving (Activity, Apparel or Equipment) (code 1275), in Sports and Recreation: Pools & Water Sports

By month

1 report from June 2024 to May 2025; the most in May 2025, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
May 20251

How badly anyone was hurt

  • No incident, no one hurt 1 CPSC: No Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No incident, no one hurt

    Made May 20, 2025, sent to the company May 23, 2025, published by CPSC Jun 9, 2025

    The product, in the report: Suunto Tank Pod wireless transmitter Model DP142

    Suunto Tank Pod (wireless tank pressure transmitter) failed without warning during a dive. This resulted in a risk of death or injury to the user due to the sudden loss of the ability to monitor tank pressure or note breathing air remaining while under water. Subsequent to the event, examination of the units battery read 1.02 volts, nominal operating voltage is 3.6 volts. Per the operators manual, battery life is stated at two (2) years. This device has about 60 dives in total on it, and has been maintained in a temperature controlled environment, so the battery depletion is not consistent with the stated operational parameters.

    Model
    DP142
    Serial number
    unable to determine not shown on the device
    Bought from
    Suunto online direct sales
    Bought
    Jan 8, 2024
    Where
    HOLLYWOOD, Florida: Place of Recreation or Sports
    Who was involved
    Age 65, Male
    The reporter’s relation to them
    Self
    As this report names them
    Brand Suunto, made or sold by SUUNTO OY
    How badly, in CPSC’s words
    No Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Scuba diving

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.