Aeris scuba diving
1 report to CPSC, the latest made Sep 29, 2017. A report isn’t a recall.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.
At a glance
From SaferProducts.gov, released Oct 25, 2026.
- 1report to CPSC
- Sep 29, 2017the latest report was made
- Sep 29, 2017the earliest
- 0with the company’s comments
- Brand
- Aeris
- Maker
- Pelagic Pressure SystemsMakers, importers or sellers, as the reports name them
- Product
- Scuba divingThe activity, its clothing or equipmentCPSC’s product type: Scuba Diving (Activity, Apparel or Equipment) (code 1275), in Sports and Recreation: Pools & Water Sports
By month
The numbers, as a table
| Month | Reports |
|---|---|
| September 2017 | 1 |
How badly anyone was hurt
- No one hurt 1 CPSC: Incident, No Injury
As each report says it, in short words; CPSC’s own words are under each.
The reports, as CPSC published them
Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.
Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.
CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.
-
No one hurt Made Sep 29, 2017, sent to the company Oct 11, 2017, published by CPSC Oct 25, 2017
The product, in the report: Aeris A300 CS Dive computer (similar to Oceanic VTX)
The incidents concern an Aeris A300 CS scuba diving computer. This computer has now failed in 3 separate incidents (in a potentially life-threatening manner) since I purchased it June 28, 2016. The first time (Sept. 2016), on changing the battery, all information concerning previous dives was erased, contrary to the statements in the manual that this information is remembered. This means the computer no longer has nitrogen saturation information which is used to determine allowable dive parameters such as how long one can safely stay at particular depths. The only remedy is to not dive for 24 hours, but even this may not fully account for this issue. I returned the unit for warranty service. At this time, Aeris had been merged with Oceanic (both companies were owned by American Underwater Products) and the merger announcement stated that all Aeris warranties were now honored by Oceanic and, indeed, they repaired the unit under warranty.
The second and third incidents occurred about a year later (August 2017). Again, a battery issue caused the computer to lock up in the middle of a dive while I was at a depth of approximately 60 feet. The unit is supposed to give a “low battery” warning but in this case it simply died with no warning in the middle of a dive. Again, this is potentially life threatening since one relies on the logged information to safely ascend without risking decompression sickness (DCS). I determined that the problem was the battery had died, but with no warning. The third incident occurred a few days later and this time, the computer screen suddenly cracked in the middle of a dive (again at about 60 ft), carrying the same life threatening implications. The danger of both of these failures is compounded because the computer also indicates how much air is remaining in the tank.
I returned the unit to the manufacturer but now, Oceanic has been purchased by another company (Huish) and they claim that they no longer warrant Aeris products. They claim that Huish bought Oceanic, but without any involvement with Aeris, despite the previous statement that Oceanic would honor Aeris warranties.
The actual computer is manufactured by a company called Pelagic Pressure Systems and Oceanic appears to market the same computer under their brand name (model VTX). I spoke with representatives of both Oceanic and Pelagic and neither company would honor the warranty or even offer a paid repair option. Further, when I described the 3 incidents above, neither company responded to the potential safety issues I have mentioned, nor did they show any interest in examining the unit in light of these failures. Recall that Oceanic did service the unit under warranty for the first incident just a year ago.
I feel there are two issues:
1. There is a possible safety issue with this dive computer which, under the right circumstances could be life-threatening. 2. Refusing to honor the warranty seems unfair and irresponsible under these circumstances. It seems particularly irresponsible not to examine the unit for information concerning the failures. Many units are in service.
- Model
- A300 CS
- Bought from
- Gigglin Marlin Dive, Texas
- Bought
- Jun 28, 2016
- Where
- HOUSTON, Texas: Other
- Who was involved
- Age 65, Male
- The reporter’s relation to them
- Self
- As this report names them
- Brand Aeris, made or sold by Pelagic Pressure Systems
- How badly, in CPSC’s words
- Incident, No Injury
CPSC’s disclaimer
Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.
Word for word, from the disclaimer in CPSC’s export.
Sources
Sources
-
U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.
Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.
Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.