Hearth Record

Back to Gas water heaters

Bosch gas water heaters

1 report to CPSC, the latest made Jan 1, 2012. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Jan 1, 2012the latest report was made
  • Jan 1, 2012the earliest
  • 1with the company’s comments
Brand
Bosch
Maker
BOSCH THERMOTECHNOLOGY CORP.Makers, importers or sellers, as the reports name them
Product
Gas water heatersCPSC’s product type: Gas Water Heaters (code 118), in Home Maintenance and Structures: Plumbing & Bath

By month

1 report from February 2011 to January 2012; the most in January 2012, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
January 20121

How badly anyone was hurt

  • No one hurt 1 CPSC: Incident, No Injury

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. No one hurt

    Made Jan 1, 2012, sent to the company Jan 25, 2012, published by CPSC Feb 8, 2012

    The product, in the report: bosch tankless hot water heater...wall mounted chimney vented

    a dangerous situation occurred when I started the washing machine which created a call for hot water. I heard the water heater clicking at least 10 seconds followed by a burst of flame. Apparently this was caused by a buildup of natural gas which occurred after the delayed ignition. It seems the gas valve opened despite no flame sensed by the flame sensor of the device. Upon further inspection, the pilot tube failed to produce sufficient gas to be lit by the ignitor which continued to spark. After 10 seconds of sparking the gas valve opened and a miniblast occurred..Immediately the device was shut off...I took it apart to see if there were any user serviceable parts but this is an engineering wonder and I noted how easy it was to remove the pilot assembly. There appeared to be 2 solenoid gas valves which I removed from the housing to inspect. I suspect that somehow one of these valves failed which prevented gas from entering the pilot tube..I put everything back together and everything seemed ok..However. this is an extremely unsafe condition which needs to be recognized and I would like some assurance that this condition never reoccurs. I need to have the safety devices checked on my unit

    Model
    gwh 425 hn
    Serial number
    789-000-26
    Bought from
    Riley plumbing, Connecticut
    Bought
    Aug 26, 2008
    Where
    southington, Connecticut: Home/Apartment/Condominium
    Who was involved
    Age 47, Male
    The reporter’s relation to them
    My Friend / Neighbor / Co-worker
    As this report names them
    Brand Bosch, made or sold by BOSCH THERMOTECHNOLOGY CORP.
    How badly, in CPSC’s words
    Incident, No Injury

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Gas water heaters

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.