Hearth Record

Back to Vacuum cleaners

Central Macinery vacuum cleaners

1 report to CPSC, the latest made Sep 26, 2019. A report isn’t a recall.

Watch it to hear when CPSC publishes new reports about it. CPSC’s own search, on saferproducts.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own search is on saferproducts.gov.

At a glance

From SaferProducts.gov, released Oct 25, 2026.

  • 1report to CPSC
  • Sep 26, 2019the latest report was made
  • Sep 26, 2019the earliest
  • 0with the company’s comments
Brand
Central Macinery
Maker
Harbor Freight ToolsMakers, importers or sellers, as the reports name them
Product
Vacuum cleanersCPSC’s product type: Vacuum Cleaners (code 115), in Home Maintenance and Structures: Home Cleaning Appliances & Equipment

By month

1 report from October 2018 to September 2019; the most in September 2019, 1.
The numbers, as a table
Reports to CPSC by the month each was made, newest first
MonthReports
September 20191

How badly anyone was hurt

  • Emergency room 1 CPSC: Injury, Emergency Department Treatment Received

As each report says it, in short words; CPSC’s own words are under each.

The reports, as CPSC published them

Reports people made to the U.S. Consumer Product Safety Commission. CPSC publishes each one after sending it to the company named, and doesn’t guarantee they’re accurate. A report isn’t a recall.

Each report is the words of the person who made it, as CPSC published them. The company’s comments, where CPSC published any, are set apart as the company’s own.

Source:

CPSC, SaferProducts.gov public database export. Released Oct 25, 2026. Updated daily.

  1. Emergency room

    Made Sep 26, 2019, sent to the company Oct 21, 2019, published by CPSC Nov 4, 2019

    The product, in the report: Central Machinery 5-Gallon Wet/Dry Vacuum/Blower, Item # 61317

    My client purchased a Central Machinery, 5 gallon Wet/Dry Vacuum/Blower from Harbor Freight in October, 2016. The label describes it as a 120 volt, 8.3 amp, 60hz model, item number 61317.

    Her daughter used the vacuum without incident for about fifteen minutes on September 22, 2019. My client then plugged the vacuum in at another location in the same house, and it began to make a strange noise. She could feel there was no suction at the end of the hose. She turned the unit off and back on a couple times. While it was on, she took hold of the handle at the top of the unit, intending to move it. At that moment, she heard a “gunshot” noise, the top separated from the motor housing, and a metal disk in the motor essentially exploded, sending bits of metal shrapnel flying in all directions.

    My client suffered deep lacerations to her left hand and right leg that necessitated emergency transport to a hospital and multiple sutures.

    Bought from
    Harbor Freight
    Bought
    Oct 10, 2016
    Where
    Louisville, Kentucky: Home/Apartment/Condominium
    Who was involved
    Age 55, Female
    The reporter’s relation to them
    My Client, Patient, Student, Etc. (professional relationship)
    As this report names them
    Brand Central Macinery, made or sold by Harbor Freight Tools
    How badly, in CPSC’s words
    Injury, Emergency Department Treatment Received

CPSC’s disclaimer

Disclaimer: CPSC does not guarantee the accuracy, completeness, or adequacy of the contents of the Publicly Available Consumer Product Safety Information Database on SaferProducts.gov, particularly with respect to information submitted by people outside of CPSC.

Source:

Word for word, from the disclaimer in CPSC’s export.

Sources

Sources
  • U.S. Consumer Product Safety Commission, SaferProducts.gov public database export.

    Released Oct 25, 2026 and checked Oct 25, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Reports of harm are from the U.S. Consumer Product Safety Commission (CPSC), on SaferProducts.gov. CPSC does not endorse Hearth Record.

Back to Vacuum cleaners

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.