Hearth Record

Ranken Jordan Pediatric Bridge Hospital

A children’s hospital in Maryland Heights, Missouri 63043

11365 Dorsett Road, Maryland Heights, Missouri 63043. (314) 872-6400.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 20, 2026.

The last 24 months 7 deficiencies in 1 month of the last 36. Last cited Jun 2024. Most serious: Condition-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
Condition-level deficiency
For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.

What did inspectors find?

The last inspection on record was on Jun 13, 2024: a standard inspection.

7 deficiencies cited in the last three years, 1 of them at condition level, the most serious.

1 deficiency at condition level, the more serious of CMS’s two levels

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

When those deficiencies happened

7 deficiencies in 1 month of the last 36. Last cited Jun 2024. Most serious: Condition-level. The last 3 years, to Oct 27, 2026.

7 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Jun 13, 2024: standard inspection7 deficiencies
  • Infection Prevention Control Abx Stewardship

    The inspectors’ words, 316 words

    “INFECTION PREVENTION CONTROL ABX STEWARDSHIP CFR(s): 482.42 The hospital must have active hospital-wide programs for the surveillance, prevention, and control of HAIs and other infectious diseases, and for the optimization of antibiotic use through stewardship. The programs must demonstrate adherence to nationally recognized infection prevention and control guidelines, as well as to best practices for improving antibiotic use where applicable, and for reducing the development and transmission of HAIs and antibiotic resistant organisms. Infection prevention and control problems and antibiotic use issues identified in the programs must be addressed in collaboration with the hospital-wide quality assessment and performance improvement (QAPI) program. This Condition is not met as evidenced by: 36473 Based on observation, interview, nationally-recognized standards review and policy review, the hospital failed to have systemic practices in place to ensure: - The containment and separation of the Sterile Processing Clean room (room used to sterilize instruments) from the exposure of contaminants. - Staff measured the amount of water used to mix the enzyme cleaner per manufacture recomendations, used to clean instruments in the Sterile Processing Decontamination room. - The Sterile Processing Decontamination room and Sterile Processing Clean room were terminally cleaned each day the areas were used. - The containment and separation of the soiled laundry and clean laundry for patients. - The cleaning and maintenance of equipment in the kitchen. - Eyewash solution was not expired for the emergency eyewash station in the kitchen. - Staff performed hand hygiene (washing hands with soap and water or use of appropriate hand sanitizer) when indicated when staff prepared medications for patients. - Staff maintained equipment used for patients. The severity and cumulative effects of these systemic practices resulted in the hospital’s non-compliance with 42 CFR 482.42 Condition of Participation: Infection Prevention and Control and Antibiotic Stewardship Programs and resulted in the hospital’s failure to ensure quality health care and safety. Please refer to A-750 for details.”

    Rule A0747. Condition-level.

  • Form And Retention Of Records

    The inspectors’ words, 400 words

    “FORM AND RETENTION OF RECORDS CFR(s): 482.24(b) The hospital must maintain a medical record for each inpatient and outpatient. Medical records must be accurately written, promptly completed, properly filed and retained, and accessible. The hospital must use a system of author identification and record maintenance that ensures the integrity of the authentication and protects the security of all record entries. This Standard is not met as evidenced by: 46554 Based on observation, interview, and policy review, the hospital failed to provide a secure environment that prevented patients’ medical records from being accessed by unauthorized individuals. This deficient practice failed to provide safe storage and retention of the Protect Health Information (PHI) in the medical records for all patients, current and past, the hospital has served. The hospital census was 41 inpatients. Findings included: 1. Observation on 06/13/2024 at 8:59 AM, showed: · The medical records department was located in the basement of the facility that requires staff access. · The medical records department was a four-person cubicle housed in an area with information technologies, revenue cycle, accounting, and the pharmacy manager’s desk. · There was not restricted access to the medical records cubicle from unauthorized staff. · There was one medical record employee present in the cubicle and three open workstations. 2. During an interview on 06/13/2024, 8:59 AM, Staff M, stated the medical records department was only accessible to staff but not restricted to medical record staff only. 3. Review of the hospital policy titled, “Medical Record Retention and Destruction”, reviewed 10/2023, showed: · Hospital shall retain, store, and destroy medical records in compliance with applicable legal and regulatory requirements. · Other acquired documentation from outside resources used for clinical decision making and treatment planning will be scanned and stored in the patient’s electronic medical record (EMR) and will be available in electronic image format. · Paper copies from outside facilities can be destroyed once scanned and verified in the patient’s EMR. · Storage areas for inactive records can include either an area inside the hospital that has been approved for record storage use, or an off-site, private, professional record storage facility with which the hospital has ab active contract for storage and retrieval. · Storage areas approved for records storage must be physically secure and environmentally controlled to protect records from unauthorized access and damage or loss due to temperature fluctuations, fire, water damage, pests and other hazards.”

    Rule A0438. Standard-level.

  • Protecting Patient Records

    The inspectors’ words, 426 words

    “PROTECTING PATIENT RECORDS CFR(s): 482.24(b)(3) The hospital must have a procedure for ensuring the confidentiality of patient records. Information from or copies of records may be released only to authorized individuals, and the hospital must ensure that unauthorized individuals cannot gain access to or alter patient records. Original medical records must be released by the hospital only in accordance with Federal or State laws, court orders, or subpoenas. This Standard is not met as evidenced by: 46554 Based on observation, interview, and policy review, the hospital failed to promptly secure paper medical records from outside providers in 18 of 18, outside paper medical records. This deficient practice failed to provide safe storage and retention of the Protect Health Information (PHI) in the medical records for all patients, current and past, the hospital has served. The hospital census was 41 inpatients. Findings Included: 1. Observation on 06/13/2024 at 8:59 AM, showed: · There was one medical record employee present in the cubicle and three open workstations. · There were outside paper medical records for 18 different patients on a table in the center of the cubicle that were not secured from employees without medical record authorization. 2. During an interview on 06/13/2024, 8:59 AM, Staff M, stated the 18 outside paper medical records had been on the table for close to a month or more after an employee for the department is no longer with them. They stated the expectation when a patient arrives with outside paper medical records is that the records should be scanned and shredded. They stated that apparently didn’t happen here. 3. Review of the hospital policy titled, “Medical Record Retention and Destruction”, reviewed 10/2023, showed: · Policy: Hospital shall retain, store, and destroy medical records in compliance with applicable legal and regulatory requirements. · Other acquired documentation from outside resources used for clinical decision making and treatment planning will be scanned and stored in the patient’s electronic medical record (EMR) and will be available in electronic image format. · Paper copies from outside facilities can be destroyed once scanned and verified in the patient’s EMR. · Storage areas for inactive records can include either an area inside the hospital that has been approved for record storage use, or an off-site, private, professional record storage facility with which the hospital has ab active contract for storage and retrieval. · Storage areas approved for records storage must be physically secure and environmentally controlled to protect records from unauthorized access and damage or loss due to temperature fluctuations, fire, water damage, pests and other hazards.”

    Rule A0441. Standard-level.

  • Secure Storage

    The inspectors’ words, 191 words

    “SECURE STORAGE CFR(s): 482.25(b)(2)(i) §482.25(b)(2)(i) - All drugs and biologicals must be kept in a secure area, and locked when appropriate. This Standard is not met as evidenced by: 36473 Based on observation, interview and policy review, the facility failed to ensure controlled substance medications were secured under double-lock in a pharmacy refrigerator. These failures had the potential to allow unauthorized access of medications. The hospital census was 41 inpatients. Findings included: 1. Observation on 6/11/24 at 3:30 PM, in the pharmacy, in an unlocked unsecure refrigerator, showed 10 drawn-up syringes (2 mg/ml) labeled Lorazepem (a controlled substance that can cause paranoia, suicidal ideation, impaired memory and judgement) one (30 ml) oral dose of Lorazepam and 16 vials (2mg/ml) of Lorazepam. 2. During an interview on 6/12/24 at 1:47 PM, Staff I, Director of Pharmacy, stated they were aware of the controlled substances needing to be double-locked and did not think about it since it was inside the pharmacy. 3. Review of the facility’s policy titled, “Pharmacy Accountability Process For Controlled Substances,” last reviewed on 09/2023, showed the direction for staff to ensure Controlled Substances were stored under a double-lock system.”

    Rule A0502. Standard-level.

  • Infection Control Surveillance, Prevention

    The inspectors’ words, 2,205 words

    “INFECTION CONTROL SURVEILLANCE, PREVENTION CFR(s): The infection prevention and control program includes surveillance, prevention, and control of HAIs, including maintaining a clean and sanitary environment to avoid sources and transmission of infection, and addresses any infection control issues identified by public health authorities; and This Standard is not met as evidenced by: 36473 Based on observation, interview, nationally-recognized standards review and policy review, the hospital failed to have systemic practices in place to ensure: - The containment and separation of the Sterile Processing Clean room (room used to sterilize instruments) from the exposure of contaminants. - Staff measured the amount of water used to mix the enzyme cleaner per manufacture recomendations, used to clean instruments in the Sterile Processing Decontamination room. - The Sterile Processing Decontamination room and Sterile Processing Clean room were terminally cleaned each day the areas were used. - The containment and separation of the soiled laundry and clean laundry for patients. - The cleaning and maintenance of equipment in the kitchen. - Eyewash solution was not expired for the emergency eyewash station in the kitchen. - Staff performed hand hygiene (washing hands with soap and water or use of appropriate hand sanitizer) when indicated when staff prepared medications for patients. - Staff maintained equipment used for patients. These failed practices had the potential to expose patients, visitors and staff to cross-contamination and increased the potential to spread infection. The hospital census was 41 inpatients. Findings included: Sterile Processing Rooms 1.Observation on 6/12/24 at 2:10 PM, in the Central Sterile Clean room, showed the room was not contained and was a high-traffic area with two laundry carts, storage carts and two closets for pediatric patient toys with cloth curtains that staff frequently access. These items in the room, prevented terminally cleaning. 2.Although requested, the facility failed to produce a terminal cleaning log of the Central Sterile Rooms on the days the areas were used. 3.During an interview with Staff C, Respiratory Therapy Director, stated they were unaware the area needed to be contained, terminally cleaned and they follow AAMI National Guidelines. 4.AAMI National Guidelines Recommendations showed staff were to terminally clean sterile processing areas each day the areas are used. Sterile processing personnel conduct critical processes, such as decontaminating, assembling, and sterilizing surgical instrumentation, in support of operating and invasive procedure rooms. As such, the recommendations for terminal cleaning apply in sterile processing areas as in areas where surgical and other invasive procedures are performed. Furthermore, sterile processing areas where decontamination occurs have some of the highest risks for environmental contamination of all perioperative areas. Environmental cleaning in sterile processing areas is critical for reducing the risk of disease transmission from reservoirs of bloodborne pathogens and microorganisms in the decontamination environment. 5.Observation with concurrent interview on 6/12/24 at 2:15 PM, in the Central Sterile Decontamination room, showed the enzymatic cleaner used to clean the instruments with manufacturer recommendations. Staff C stated they were not measuring the amount of water to mix the enzymatic cleaner per the manufacturer recommendations. 6.During an interview on 6/12/24 at 2:20 PM, Staff C, Respiratory Therapy Director, stated they follow AAMI National Guidelines. 7.During an interview on 6/13/24 at 12:22 PM, Staff Y, Infection Prevention and Quality Specialist, stated they expected staff to accurately measure the cleaners per manufacturer guidelines and they were unaware of the high traffic in the Central Sterile Clean room. 8.Review of the American National Standards Institute (ANSI) and Associate for the Advancement of Medical Instrumentation (AAMI) document titled, “ANSI/AAMI ST79:2017, Comprehensive Guide to Steam Sterilization and Sterility Assurance in Health Care Facilities Amendment 2: Inspection of Insulated Instruments,” dated 2020, showed each time a medical device is processed, it should be visually inspected for cleanliness and integrity. When recommended in the instrument manufacturer ’ s written IFU, enhanced inspection should be used and the enhanced visualization tool manufacturer ’ s written IFU should be followed. Health care facilities should have a method of ensuring the cleanliness and integrity of every instrument and medical device used in every procedure. Laundry 9. Observation on 6/12/24 at 4:20 PM, in the laundry room, showed the washers and dryers across from each other and the soiled laundry brought into the clean room exposing contaminants to the clean laundry. 10.During an interview on 6/12/24 at 4:30 PM, Staff K, Director of Facilities, stated they did not realize the soiled clothes were exposed in the clean laundry room. 11.During an interview on 6/13/24 at 12:22 PM, Staff Y, Infection Preventionist and Quality Specialist, stated they were unaware of the exposure in the laundry room and they did not perform environmental rounds in the laundry. 12.Review of the facility ’ s policy titled, “Laundry Service and Linen Handling,” last reviewed on 05/2022, showed laundry was to be handled and processed in such a manner to prevent the transmission of infectious organisms from one patient to another or from patient to staff. Kitchen 13.Observation on 6/10/24 at 3:15 PM, in the kitchen, showed: - An unclean hotbox/holding box. - A large amount of residue on the range oven. - A large amount of residue and dirt on the top of the dishwasher. - Residue on the wall behind the dishwasher. - Eyewash solution with an expiration date of 08/2023 in the emergency eyewash station. 14.During an interview on 6/11/24 at 10:30 AM, Staff A, Dietary Manager, stated they expected staff to clean the hotbox, range oven, dishwasher and wall behind the dishwasher. They also stated they expected staff to check the eyewash solution for current dates. 15.During an interview on 6/13/24 at 12:22 PM, Staff Y, Infection Preventionist and Quality Specialist, stated they performed kitchen environmental rounds quarterly, they expected staff to maintain any need of cleaning and repairs and they expected the staff to check for expiration dates. 16.Review of the facility ’ s policy titled, “Dietary Manual,” last reviewed 07/2023, showed food contact surfaces were to be cleaned once per day and non-food contact surfaces of equipment shall be cleaned as often as necessary to keep the equipment free of accumulation of dust, dirt, food particles and other debris. 17.Review of the facility ’ s policy titled, “Infection Control Plan,” last reviewed on 03/2024, showed the Infection Prevention staff were to complete hospital-wide rounds on an ongoing, routine basis, including but not limited to: central line, kitchen, isolation precaution, high touch surface cleaning, and environment of care rounds. MEDICATION ADMINISTRATION 18. Observation on 06/12/24 at 9:00 AM, showed Staff Z, Registered Nurse (RN), on the West Unit prepared and administered medications to Patient #5: - Staff Z failed to perform hand hygiene upon entry into the treatment room to administer two subcutaneous (Sub Q - under the skin) injections. - With un-gloved hands, Staff Z removed the bar code scanner from the computer workstation on wheels and scanned the patient’s identification (ID) band and each bar code on the medications. - After scanning the bar codes on the medications, Staff Z put on gloves, however, Staff Z failed to perform hand hygiene before gloving. - Patient #5 dropped an object onto the floor and Staff Z picked the item off the floor, removed gloves and re-gloved, however, Staff Z failed to perform hand hygiene after removal of gloves or before re-gloving. - After Staff Z administered the Sub Q medications, Staff Z removed gloves but failed to perform hand hygiene after glove removal. 19. Observation on 06/12/24 at approximately 9:30 AM, showed Staff U, RN, on the East Unit prepared and administered medications to Patient #18. - Staff U failed to perform hand hygiene before Staff U retrieved medications from the automated medication dispensing system to administer medication to Patient #18 per the patient’s gastrostomy tube (G-Tube - a soft flexible tube inserted through the skin of the abdomen and into the stomach, used to administer medications, fluids, and tube feedings). - Staff U performed hand hygiene upon entry into the patient’s room and put on gloves, removed the bar code scanner from the computer workstation on wheels and scanned the patient’s ID band and each medication bar code. - After Staff U used the bar code scanner, Staff U removed gloved and re-gloved, however, Staff U failed to perform hand hygiene after removal of gloves or before re-gloving. - Staff U attached the patient’s G-Tube to the patient and administered each medication and at the completion of administering the medications, Staff U flushed the patient’s G-Tube with water. - Wearing the same gloves worn to administer the medications and flush the patient’s G-Tube, Staff U applied topical medication to the patient per orders. 20.Staffs’ failure to perform hand hygiene and remove/change gloves when indicated increased the risk of cross-contamination towards patients, staff, supplies and anything touched with contaminated hands and/or gloves. 21. During an interview on 06/12/24 at 9:11 AM, Staff Z, RN, stated: - Staff received education/training related to hand hygiene and gloving during orientation, on an on-going basis, and yearly per electronic education. - Staff was expected to perform hand hygiene: - Upon entry & exit of patients’ rooms; - Before and after staff touched a patient; - Before gloving, after removal of gloves, and before re-gloving; and - Anytime staff touched medical equipment. - Staff was expected to wear/change gloves: - Anytime staff touched a patient; - Anytime gloves are indicated. 22. During an interview on 06/13/24 at 11:54 AM, Staff D, East Unit Nursing Manager, stated staff was expected to perform hand hygiene and wear/changes gloves: - Upon entry and exit of patients’ rooms. - When retrieving and handling medications. - Anytime staff touch anything in the patient’s environment. - Before gloving, after removal of gloves and before re-gloving. - Remove gloves after providing care for a patient and perform hand hygiene before retrieving supplies from the supply drawer. - Follow the facility’s policy and procedure related to hand hygiene. 23. During an interview on 06/13/24 at 11:54 AM, Staff F, West Unit Nursing Manager, stated staff was expected to perform hand hygiene and wear/change gloves: - With aseptic techniques. - The 5 Moments of Hand Hygiene. - Before medication preparation and administration. 24. During an interview on 06/13/24 at 12:53 PM, Staff L, Infection Control Prevtionist, stated staff was expected to: -Follow the 5 Moments of Hand Hygiene. - To removal gloves after using the bar code scanner on patients’ ID bands and bar codes on medications, before removing medications from the medication packages, and before administering medication to the patient. - Perform hand hygiene before gloving, after removal of gloves, and before re-gloving. - Follow the facility’s hand hygiene policy and procedure. 25. Observation on 6/11/24 at 2:07 PM, in Patient #12 ’ s room, during a J tube (Jejunostomy feeding tube, a soft, plastic tube placed through the skin of the abdomen into the midsection of the small intestine used to administer food and medication) medication administration, showed: - Staff H, Registered Nurse (RN), washed hands and put gloves on; - Scanned the medication and the patient ’ s wrist band; - Touched the computer; - Touched the patient; - Opened the medication and placed in the crusher; - Mixed medication with 10 ml of water; - Administered medication; - Administered 5 ml of flush; - Recapped the patient ’ s J tube and signed off the computer; and - Showed Staff H used the same contaminated gloves throughout the medication administration. 26. During an interview on 6/11/24 at 2: 10 PM, Staff H, RN, stated they did not realize how much they touched the computer with the same gloves. 27. During an interview on 6/13/24 at 12:22 PM, Staff Y, Infection Preventionist and Quality Specialist, stated they expected staff to follow WHO and the five moments of hand hygiene. 28. Review of the facility’s policy titled, “Hand Hygiene,” dated 03/2024, showed staff directives: - The 5 Moments for Hand Hygiene, defined by the WHO (World Health Organization) - Before touching a patient - Before clean/aseptic procedures - After body fluid exposure/risk (and after removing gloves) - After touching a patient - After touching patient surroundings - Other indication for handwashing and hand antiseptic - Decontaminate hands after contact with body fluids or excretions, mucous membranes, non-intact skin, and wound dressings if hands are not visibly soiled. - Decontaminate hands if moving from a contaminated-body site to a clean-body site during patient care. - Staff education: All staff will be educated regarding proper hand hygiene practice upon hire and on an ongoing basis. EQUIPMENT 29. Observation on 06/12/24 and 06/13/24, on the East Unit showed a large medical wedge cushion on a stretcher located by Room 15. The top and sides of the wedge cushion had several strips of wide gray colored adhesive tape on the top and each side. 30. During an interview on 06/13/24 at 8:57 AM, Staff DD, QAPI, acknowledged the large medical wedge cushion on the stretcher located by Room 15 had wide gray colored strips of adhesive tape on the top and sides. Staff DD stated the wedge cushion belonged to the facility and was not a patient’s. 31.The wide gray colored strips of adhesive tape on the large medical wedge cushion made the surface non-cleanable and increased the risk to harbor bacteria and germs. 18018”

    Rule A0750. Standard-level.

  • Initial Comments - Not A Deficiency Citation

    “42 CFR 483.90 (a) The facility does not meet the applicable provisions of the 2012 exixting edition of the Life Safety Code of the National Fire Protection Association (NFPA) and related reference documents.”

    Rule K0000. Standard-level.

  • Electrical Systems - Essential Electric Syste

    The inspectors’ words, 1,152 words

    “Electrical Systems - Essential Electric Syste CFR(s): NFPA 101 Electrical Systems - Essential Electric System Maintenance and Testing The generator or other alternate power source and associated equipment is capable of supplying service within 10 seconds. If the 10-second criterion is not met during the monthly test, a process shall be provided to annually confirm this capability for the life safety and critical branches. Maintenance and testing of the generator and transfer switches are performed in accordance with NFPA 110. Generator sets are inspected weekly, exercised under load 30 minutes 12 times a year in 20-40 day intervals, and exercised once every 36 months for 4 continuous hours. Scheduled test under load conditions include a complete simulated cold start and automatic or manual transfer of all EES loads, and are conducted by competent personnel. Maintenance and testing of stored energy power sources (Type 3 EES) are in accordance with NFPA 111. Main and feeder circuit breakers are inspected annually, and a program for periodically exercising the components is established according to manufacturer requirements. Written records of maintenance and testing are maintained and readily available. EES electrical panels and circuits are marked, readily identifiable, and separate from normal power circuits. Minimizing the possibility of damage of the emergency power source is a design consideration for new installations. 6.4.4, 6.5.4, 6.6.4 (NFPA 99), NFPA 110, NFPA 111, 700.10 (NFPA 70) This Standard is not met as evidenced by: 19172 Based on observation and facility staff interview, facility staff failed to provide an emergency stop switch away from the generator set location. This facility had a census of 43. Findings Included: 1. Observation 6/11/24, during the facility tour, showed the emergency generator’s emergency stop switch located on the exterior generator casing without protection from activation. 2. During an interview on 6/11/24 at approximately 9:26 A.M., the facility maintenance director confirmed the observation. 3. NFPA 110, Standard for Emergency and Standby Power Systems, 2010 edition states: 5.6.5.6* All installations shall have a remote manual stop station of a type to prevent inadvertent or unintentional operation located outside the room housing the prime mover, where so installed, or elsewhere on the premises where the prime mover is located outside the building. 5.6.5.6.1 The remote manual stop station shall be labeled. 8.4.2* Diesel generator sets in service shall be exercised at least once monthly, for a minimum of 30 minutes, using one of the following methods: (1) Loading that maintains the minimum exhaust gas temperatures as recommended by the manufacturer (2) Under operating temperature conditions and at not less than 30 percent of the EPS nameplate kW rating 8.4.2.1 The date and time of day for required testing shall be decided by the owner, based on facility operations. 8.4.2.2 Equivalent loads used for testing shall be automatically replaced with the emergency loads in case of failure of the primary source. 8.4.2.3 Diesel-powered EPS installations that do not meet the requirements of 8.4.2 shall be exercised monthly with the available EPSS load and shall be exercised annually with supplemental loads at not less than 50 percent of the EPS nameplate kW rating for 30 continuous minutes and at not less than 75 percent of the EPS nameplate kWrating for 1 continuous hour for a total test duration of not less than 1.5 continuous hours. 8.3 Maintenance and Operational Testing. 8.3.1* The EPSS shall be maintained to ensure to a reasonable degree that the system is capable of supplying service within the time specified for the type and for the time duration specified for the class. 8.3.2 A routine maintenance and operational testing program shall be initiated immediately after the EPSS has passed acceptance tests or after completion of repairs that impact the operational reliability of the system. 8.3.2.1 The operational test shall be initiated at an ATS and shall include testing of each EPSS component on which maintenance or repair has been performed, including the transfer of each automatic and manual transfer switch to the alternate power source, for a period of not less than 30 minutes under operating temperature. 8.3.3 A written schedule for routine maintenance and operational testing of the EPSS shall be established. 8.3.4 A permanent record of the EPSS inspections, tests, exercising, operation, and repairs shall be maintained and readily available. 8.3.4.1 The permanent record shall include the following: (1) The date of the maintenance report (2) Identification of the servicing personnel (3) Notation of any unsatisfactory condition and the corrective action taken, including parts replaced (4) Testing of any repair for the time as recommended by the manufacturer 8.3.5* Transfer switches shall be subjected to a maintenance and testing program that includes all of the following operations: (1) Checking of connections (2) Inspection or testing for evidence of overheating and excessive contact erosion (3) Removal of dust and dirt (4) Replacement of contacts when required 8.3.6 Paralleling gear shall be subject to an inspection, testing, and maintenance program that includes all of the following operations: (1) Checking of connections (2) Inspection or testing for evidence of overheating and excessive contact erosion (3) Removal of dust and dirt (4) Replacement of contacts when required 8.3.7* Storage batteries, including electrolyte levels or battery voltage, used in connection with systems shall be inspected weekly and maintained in full compliance with manufacturer ’ s specifications. 8.3.7.1 Maintenance of lead-acid batteries shall include the monthly testing and recording of electrolyte specific gravity. Battery conductance testing shall be permitted in lieu of the testing of specific gravity when applicable or warranted. 8.3.7.2 Defective batteries shall be replaced immediately upon discovery of defects. 8.3.8 A fuel quality test shall be performed at least annually using tests approved by ASTM standards. 8.4 Operational Inspection and Testing. 8.4.1* EPSSs, including all appurtenant components, shall be inspected weekly and exercised under load at least monthly. 8.4.6 Transfer switches shall be operated monthly. 8.4.6.1 The monthly test of a transfer switch shall consist of electrically operating the transfer switch from the standard position to the alternate position and then a return to the standard position. 7.2.4* Minimizing the possibility of damage resulting from interruptions of the emergency source shall be a design consideration for EPSS equipment. A.7.2.4 When installing the EPSS equipment and related auxiliaries, environmental considerations should be given, particularly with regard to the installation of the fuel tanks and exhaust lines, or the EPS building, or both. To protect against disruption of power in the facility, it is recommended that the transfer switch be located as close to the load as possible. The following are examples of external influences: (1) Natural conditions (a) Storms (b) Floods (c) Earthquakes (d) Tornadoes (e) Hurricanes (f) Lightning (g) Ice storms (h) Wind (i) Fire (2) Human-caused conditions (a) Vandalism (b) Sabotage (c) Other similar occurrences (3) Material and equipment failures For natural conditions, EPSS design should consider the “100-year storm” flooding level or the flooding level predicted by the Sea, Lake, and Overland Surges from Hurricanes”

    Rule K0918. Standard-level.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Jun 13, 2024Standard inspection5 deficiencies cited
Jun 13, 2024Standard inspection2 deficiencies cited

How do patients fare?

  • CMS gives no overall : “Data are shown only for hospitals that participate in the Inpatient Quality Reporting (IQR) and Outpatient Quality Reporting (OQR) programs.”
  • CMS gives no : “Data are shown only for hospitals that participate in the Inpatient Quality Reporting (IQR) and Outpatient Quality Reporting (OQR) programs.”
Ratings and measures, as published
MeasureRating
Overall ratingCMS’s overall hospital quality star rating, 1 to 5Not rated
Patient survey ratingCMS star rating from its survey of the hospital’s patients (HCAHPS), 1 to 5Not rated

Is it certified, and in good standing?

  • Medicare-certified children’s hospital since Jul 31, 2002.
  • Ownership: voluntary non-profit - other.
  • It is not accredited by a private organisation, so the state carries out its routine inspections for Medicare.
  • Cited at in the last three years: it didn’t meet a whole condition of Medicare’s rules for hospitals.
  • Voluntary non-profit - Other.
Source:

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Jul 15, 2026. Updated quarterly.

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for hospitals.
  • CMS’s HAC Reduction Program file has no result for it: the program covers general acute care hospitals Medicare pays under its inpatient prospective payment system.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, Hospital-Acquired Condition (HAC) Reduction Program. Released Aug 13, 2026. Updated yearly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

What do patients say about their care?

  • CMS doesn’t publish staffing levels for hospitals.
Source:

CMS, Patient survey (HCAHPS) - Hospital and Timely and Effective Care - Hospital. Released Aug 13, 2026. Updated quarterly.

Who owns it?

  • 7 owners or officers are people: Thomas Minogue (corporate director, 25%); Christopher Cioffi (corporate director, 25%); Nick Williamson (corporate director, 25%); Elizabeth Prosperi (corporate director, 25%); Kim Buie (corporate officer); Shawn Dryden (corporate officer); Shawn Dryden (managing employee (on the payroll)).
  • CMS’s Provider of Services file records no change of ownership.
  • No private-equity firm among the owners CMS lists.
  • No real-estate investment trust among the owners CMS lists.
Source:

CMS, Hospital All Owners and Hospital Enrollments. Released Sep 29, 2026. Updated monthly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Jul 15, 2026. Updated quarterly.

How does it compare nearby?

  • Of the 12 hospitals CMS lists in St. Louis County, 9 have an overall star rating from CMS: 3 rated 5 of 5, 4 rated 4 of 5, 1 rated 3 of 5, 1 rated 2 of 5.
  • CMS gives this hospital no overall star rating to compare.
Source:

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for hospitals, so none are shown. The one payment cut CMS publishes for each hospital, under its Hospital-Acquired Condition Reduction Program, is shown where it applies.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • Most hospitals are accredited by a private organisation (The Joint Commission, DNV and others) whose routine inspections stand in for the state’s; those reports aren’t public, and QCOR holds only the state’s surveys: no inspection on record here doesn’t mean none took place.
  • QCOR says its hospital inspection data are complete only through September 17, 2026, while it moves to a new system.
  • CMS doesn’t publish staffing levels for hospitals.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 27, 2026.

From the hospital

The public record above comes first. Anything the hospital adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the hospital will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the hospital”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.