Pediatric Renal Center

A dialysis facility in San Juan, Puerto Rico 00919

Pediatric Renal Ctr Dept. De Salud, Dr Antonio Ortiz PO Box 191079, San Juan, Puerto Rico 00919. (787) 474-0333.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 6 deficiencies in 1 month of the last 36. Last cited Jul 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean2
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jan 29, 2026: a standard inspection.

6 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 1 month of the last 36. Last cited Jul 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jul 11, 2024: complaint inspection6 deficiencies
  • Ic - Sanitary Environment

    The inspectors’ words, 185 words

    “IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 47384 Based on observations made of the water treatment area and the treatment area with the facility’s Unit Supervisor (employee #2) and interviews, it was determined that the facility failed to monitor the environment to ensure that it is sanitary to reduce possible transmission of infectious agents. Findings include: 1.It was observed that the floor of the water treatment unit was wet. To the surveyor ask questions about the reason for the water on the floor, the water treatment technician answered that it was due to the draining of the day tank. 2. During observation of the water treatment area and treatment area between the first and second shifts with the facility’s Supervisor (employee #2) on 07/11/24 from 8:30 AM till 1:00 PM, wet gypsum board particles were observed behind the water purification tanks. This allows the generation of bacteria in the area.”

    Rule V0111. Standard-level. From a complaint.

  • Carbon Adsorption - Monitoring, Testing Frequency

    The inspectors’ words, 281 words

    “CARBON ADSORP-MONITOR, TEST FREQUENCY CFR(s): 494.40(a) 6.2.5 Carbon adsorption: monitoring, testing freq Testing for free chlorine, chloramine, or total chlorine should be performed at the beginning of each treatment day prior to patients initiating treatment and again prior to the beginning of each patient shift. If there are no set patient shifts, testing should be performed approximately every 4 hours. Results of monitoring of free chlorine, chloramine, or total chlorine should be recorded in a log sheet. Testing for free chlorine, chloramine, or total chlorine can be accomplished using the N.N-diethyl-p-phenylene-diamine (DPD) based test kits or dip-and-read test strips. On-line monitors can be used to measure chloramine concentrations. Whichever test system is used, it must have sufficient sensitivity and specificity to resolve the maximum levels described in [AAMI] 4.1.1 (Table 1) [which is a maximum level of 0.1 mg/L]. Samples should be drawn when the system has been operating for at least 15 minutes. The analysis should be performed on-site, since chloramine levels will decrease if the sample is not assayed promptly. This Standard is not met as evidenced by: 47384 Based on observations made of the water treatment and the treatment area with the facility’s Unit Supervisor (employee #2) and interviews, it was determined that the facility failed to monitor and test for chlorine, chloramine or total chlorine. Findings include: During observation of the chlorine test carried out in the first carbon tank and the evaluation of the procedure standard “ Procedimiento para hacer muestra de cloro y cloramina en los tanques de carbon”, it was identified that the personnel has a measurement of 0.5 ppm as a parameter. AAMI maximum level permitted for a test should be 0.1 mg/L.”

    Rule V0196. Standard-level. From a complaint.

  • Ro - Meets Aami/Monitored, Recorded On Log

    The inspectors’ words, 279 words

    “RO-MEETS AAMI/MONITORED, RECORDED ON LOG CFR(s): 494.40(a) 5.2.7 Reverse osmosis: meets AAMI/monitored/recorded on log Refer to RD62:2001, 4.3.7 Reverse osmosis: When used to prepare water for hemodialysis applications, either alone or as the last stage in a purification cascade, reverse osmosis systems shall be shown to be capable, at installation, of meeting the requirements of Table 1, when tested with the typical feed water of the user, in accordance with the methods of [AAMI] 5.2.2. 5.2.7 Reverse osmosis Users should carefully follow the manufacturer’s instructions for feed water treatment and monitoring to ensure that the RO is operated within its design parameters. 6.2.7 Reverse osmosis All results of measurements of RO performance should be recorded daily in an operating log that permits trending and historical review. This Standard is not met as evidenced by: 47384 Based on the review of documents related to Reverse Osmosis (RO) system monitoring, it was determined that the facility failed to secure to comply with parameters established by their own policies. Findings include: 1. During review of the document “ Registro Diario de Equipo Pre Tratamiento de Agua RO Central “ it was observed that the RO temperature parameters stated by the facility between 25 degrees and 35 degrees were not followed. The record of temperatures for the RO evaluated covers from July 1 to July 11, 2024, and in all lines the recorded measurements were below the lowest value of the parameter established. 2. During review of the document “ Registro Diario de Equipo Pre Tratamiento de Agua RO Central “ it was observed that the pre filter and post filter of 30 microns did not comply with parameters established by the facility.”

    Rule V0199. Standard-level. From a complaint.

  • Dist Sys - Culture/Lal/Sample Sites/Frequency(New)/Log

    The inspectors’ words, 327 words

    “DIST SYS-CULTURE/LAL/SITES/FREQ(NEW)/LOG CFR(s): 494.40(a) 6.3.3 Water distribution systems: culture/LAL sample sites/frequency (new)/log Water distribution piping systems should be monitored for bacteria and endotoxin levels. Bacteria and endotoxins shall not exceed the levels specified in [AAMI] 4.1.2. [(i.e., bacteria <200 CFU/mL and endotoxin <2 EU/mL] Bacteria and endotoxin testing should be conducted at least monthly. For a newly-installed water distribution piping system, or when a change has been made to an existing system, it is recommended that weekly testing be conducted for 1 month to verify that bacteria or endotoxin levels are consistently within the allowed limits. Monitoring should be accomplished by taking samples from the first and last outlets of the water distribution loop and the outlets supplying reuse equipment and bicarbonate concentrate mixing tanks. If the results of this testing are unsatisfactory, additional testing (e.g., ultrafilter inlet and outlet, RO product water, and storage tank outlet) should be undertaken as a troubleshooting strategy to identify the source of contamination, after which appropriate corrective actions can be taken. Bacteria and endotoxin levels shall be measured as specified in ANSI/AAMI RD62:2001 (see 2.3). All bacteria and endotoxin results should be recorded on a log sheet to identify trends that may indicate the need for corrective action. This Standard is not met as evidenced by: 47384 Based on the review of documents related to Reverse Osmosis (RO) system monitoring, it was determined that the facility failed to maintain bacteria and endotoxin levels as specified in The Association for the Advancement of Medical Instrumentation (AAMI). Findings include: During review of document related to the monitoring of the Central RO endotoxin monitoring it was identified that for the periods of 2022 to the month of July 2024 the facility identified at least five (5) times levels of endotoxins out of specifications of AAMI regulations. Dates of out of parameters endotoxin levels: 06/14/2022 - (0.921 EU) 09/22/2023 - (1.4 EU) 11/17/2023 - (1.91 EU) 02/17/2024 - (1.70 EU) 04/15/2024 -( 5.0 EU)”

    Rule V0213. Standard-level. From a complaint.

  • Personnel - Training Program/Periodic Audits

    The inspectors’ words, 190 words

    “PERSONNEL-TRAINING PROGRAM/PERIODIC AUDITS CFR(s): 494.40(a) 9 Personnel: training program/periodic audits A training program that includes quality testing, the risks and hazards of improperly prepared concentrate, and bacterial issues is mandatory. Operators should be trained in the use of the equipment by the manufacturer or should be trained using materials provided by the manufacturer. The training should be specific to the functions performed (i.e., mixing, disinfection, maintenance, and repairs). Periodic audits of the operators’ compliance with procedures should be performed. The user should establish an ongoing training program designed to maintain the operator’s knowledge and skills. This Standard is not met as evidenced by: 47384 Based on the review of documents related to training for personnel responsible for the water and dialysate systems and competencies it was determined that the facility failed to have a training program that includes quality testing, the risks and hazards of improperly prepared concentrate, and bacterial issues as stated in AAMI RD 52. Findings include: 1. Facility failed to provide evidence of annual training for personnel responsible for the water and dialysate systems. 2. Facility failed to provide evidence of personnel certifications on water system management.”

    Rule V0260. Standard-level. From a complaint.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 209 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 47384 Based on observations made of the water treatment and the treatment area with the facility’s Unit Supervisor (employee #2) it was determined that the facility failed to implement and maintain a program to ensure that all equipment is maintained and operated in accordance with the manufacturer’s recommendations. Findings include: 1. During observation of the water treatment area it was noted that metal framing for both day tank and RO had rust due to contact with water on floor. 2. All four (4) water treatment tanks were observed with broken blue masking tape on the bottom part of the tank. 3. Mixing tank was observed in the room next to the water treatment room, this tank has not been in use since the dialysis machines had been changed to B-bags. During the survey the water technician filled the mixing tank which caused the units day tank to fall beneath the safe level and caused the water level alarm to activate.”

    Rule V0403. Standard-level. From a complaint.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Jan 29, 2026Standard inspectionNo deficiencies cited
Jul 11, 2024Complaint inspection6 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Oct 28, 1993.
  • Run as a non-profit.
  • No deficiency on record in the last three years.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • 6 deficiencies cited in the last three years came from inspections that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis and peritoneal dialysis.
  • Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
  • 5 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • CMS lists it as independent, not owned or managed by a chain.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS gives no : “Not enough quality measure data to calculate a star rating.”
  • Compared by CMS with what it expects for the facility’s patients: hospital admissions, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Survey data not available for this reporting period.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 5Not rated
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 7 dialysis facilities CMS lists in San Juan, 6 have a star rating from CMS: 6 rated 1 of 5.
  • CMS gives this facility no star rating to compare.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.