Fkc Easton
A dialysis facility in Easton, Pennsylvania 18045
3501 Northwood Avenue, Easton, Pennsylvania 18045. (610) 253-4278.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 6 deficiencies cited in the last three years
- 21 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jul 19, 2024: a standard inspection.
6 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
6 deficiencies in 1 month of the last 36. Last cited Jul 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jul 19, 2024: standard inspection6 deficiencies
-
Ic - Wear Gloves/Hand Hygiene
The inspectors’ words, 294 words
“IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 36372 Based on review of facility policy/procedure, observations, and an interview with the facility Clinical Nurse Manager, the facility failed to ensure the staff followed infection control protocols, included but not limited to, hand hygiene/don clean gloves, for one (1) of two (2) ‘Discontinuation of Dialysis and Post Dialysis Care for AV Fistula or Graft’ observations (Observation#2) Findings include: A review was conducted of facility policy/procedure on July 18, 2024 at approximately 1:15 p.m. Policy ‘Clinical Services’ Termination of Treatment Using Arteriovenous Fistula or Graft and Optiflux Single Use Ebeam Dialyzer’ (Setting: IC. IPS) Termination: Disconnecting the Patient’ step (3) states “Disconnect the bloodlines from the needle lines and remove the needles according to the Post Treatment Needle Removal Procedure’. Policy ‘Clinical Services’ ‘Post Treatment Fistula Needle Removal’ (Setting: IC. HT, IPS) ‘Procedure’ section (2) states “Person removing needles perform hand hygiene and don clean gloves.” Observations conducted in the patient treatment area on July 16, 2024 between approximately 8:20 a.m. and 12:15 p.m. and on July 17, 2024 between approximately 11:00 a.m. and 11:30 a.m, revealed the following: Observation #2: During observation #2 of 2 of ‘Discontinuation of Dialysis and Post Dialysis Care for AV Fistula or Graft’ on 07/16/24 at approximately 9:20 a.m., of patient #7, Employee #12 at station #4 did not perform hand hygiene/don clean gloves after reinfusing the extracorporeal circuit/disconnecting the bloodlines and before removing the needles. An interview with the facility Clinical Nurse Manager on July 18, 2024 at approximately 1:30 p.m. confirmed the above findings.”
-
Ic - Staff Education Re Catheters/Catheter Care
The inspectors’ words, 523 words
“IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 36372 Based on a review of facility policy/procedure, observations, and an interview with the facility Clinical Nurse Manager, the facility failed to ensure that clinical staff maintain aseptic technique for the care of vascular accesses, including intravascular catheters for one (1) of two (2) ‘Central Venous Catheter (CVC) Exit Site Care’ and ‘Initiation of Dialysis with Central Venous Catheter’ observations (Observation #2). Findings: A review was conducted of facility policy/procedure on July 18, 2024 at approximately 1:15 p.m. Policy ‘Central Venous Catheter (CVC) Dressing Change’ (Setting: IPS) ‘Purpose’ states “The purpose of this procedure is to ....... and maintaining a protective barrier to prevent infection.” ‘Removal of Dressing and Inspection of Site’ ‘Follow the steps below to remove a catheter dressing and inspect the exit site before initiation of treatment: ...Step (5) “Inspect and remove the old dressing. ...” ...... ‘Applying the dressing’ Step (1) ....Apply the catheter dressing over the dry exit site, .... Policy ‘Initiation of Treatment using a Central Venous Catheter (CVC) and Optiflux Single Use Ebeam Dialyzer’ (Setting: IC, IPS) ‘Preparing the Catheter: Dressing Change’ “..... dressing replacement must be completed prior to accessing the bloodstream. ....” ‘Prior to Initiation: Assessment and Machine Parameters’ Step (1) “Perform hand hygiene and donn full PPE.” ....Step (9) “....perform hand hygiene then donn new gloves.” ‘Preparing the Catheter: Disinfection of the Catheter Connections, Heparin Removal, Flushing the Catheter and Heparin Administration’ step (1) states “Check to make sure catheter clamps are closed. Step (2) states “Remove cap from clamped arterial limb.” Step (3) states “Using a sterile alcohol pad .....” Observations conducted in the patient treatment area on July 16, 2024 between approximately 8:20 a.m. and 12:15 p.m. and on July 17, 2024 between approximately 11:00 a.m. and 11:30 a.m, revealed the following: Observation #2: On 07/16/24 at approximately 9:00 a.m. while observing ‘Central Venous Catheter Exit Site Care’ observation #2, for patient #2, station #1; employee #7 left the CVC site exposed and began ‘Initiation of Dialysis with Central Venous Catheter’. After completing the initiation steps and connecting sterile syringes to each port, employee #7 then applied a sterile dressing to the CVC exit site. An interview with the facility Clinical Nurse Manager on July 18, 2024 at approximately 1:30 p.m. confirmed the above findings.”
-
Pe - Equipment Maintenance - Manufacturer’S Dfu
The inspectors’ words, 475 words
“PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 36372 Based on a review of facility policy/procedure, manufacturers directions for use, and an interview with the facility Clinical Nurse Manager, facility failed to ensure home therapy dialysis machines were maintained per the manufacturers directions for use for six (6) of six (6) dialysis machine (DM) maintenance documentation records reviewed (DM#1- DM#6). Findings: A review was conducted of facility policy/procedure on July 18, 2024 at approximately 1:15 p.m. ‘NxStage Machine: Operational Preparation’ (Setting: IC, HT) Policy’ states “ The NxStage machine will be operated according to the appropriate NxStage Users Guide and if indicated, the Pure Flow Users Guide and Express Warmer Users Guide.” A review was conducted of the dialysis machine manufacturers ‘NxStage Pureflow SL User Guide’ on July 18, 2024 at approximately 10:30 a.m. ‘Item’ ’’Air Filter’ Maintenance Schedule’ states “Clean or replace every three months. It might require more frequent cleaning depending on environmental conditions.” Maintenance documentation was requested from the facility home therapy nurse (employee #13) on 07/18/24 at approximately 9:30 a.m. Employee #13 could not produce documentation to show the dialysis machine air filters were maintained according to the manufacturers directions for use. The following machines are currently in use by home therapy patients: DM#1: This NxStage dialysis machine (serial #51326) is currently utilized by patient #8 (started home therapy 07/05/23). No documentation provided of the machine air filter being cleaned or replaced every three months. DM#2: This NxStage dialysis machine (serial #37593) is currently utilized by patient #9 (started home therapy 09/11/23). No documentation provided of the machine air filter being cleaned or replaced every three months. DM#3: This NxStage dialysis machine (serial #41088) is currently utilized by patient #10 (started home therapy 07/17/23). No documentation provided of the machine air filter being cleaned or replaced every three months. DM#4: This NxStage dialysis machine (serial #45997) is currently utilized by patient #11 (started home therapy 07/05/23). No documentation provided of the machine air filter being cleaned or replaced every three months. DM#5: This NxStage dialysis machine (serial #55271) is currently utilized by patient #4 (started home therapy 05/22/23). No documentation provided of the machine air filter being cleaned or replaced every three months. DM#6: This NxStage dialysis machine (serial #6250) is currently utilized by patient #12 (started home therapy 08/01/23). No documentation provided of the machine air filter being cleaned or replaced every three months. An interview with the facility Clinical Nurse Manager on July 18, 2024 at approximately 1:30 p.m. and email correspondence with the facility Administrator on July 19, 2024 at approximately 10:35 a.m. confirmed the above findings.”
-
Vascular Access - Monitor/Referrals
The inspectors’ words, 281 words
“POC-VASCULAR ACCESS-MONITOR/REFERRALS CFR(s): 494.90(a)(5) The interdisciplinary team must provide vascular access monitoring and appropriate, timely referrals to achieve and sustain vascular access. The hemodialysis patient must be evaluated for the appropriate vascular access type, taking into consideration co-morbid conditions, other risk factors, and whether the patient is a potential candidate for arteriovenous fistula placement. This Standard is not met as evidenced by: 36372 Based on a review of facility policy/procedure, observations, and an interview with the facility Clinical Nurse Manager, the facility failed to ensure that the staff performed proper aseptic technique while initiating treatment for one (1) of two (2) ‘Access of AV Fistula or Graft for Initiation of Dialysis’ observations (Observation #2). Findings include: A review was conducted of facility policy/procedure on July 18, 2024 at approximately 1:15 p.m. Policy ‘Clinical Services’ ‘Access Assessment and Cannulation’ ‘Assessment of Vascular Assess’ (Setting: IC, HT) ‘Assessment of Vascular Access’ Step (1) states “Prior to treatment, ask patient to wash area with soap per hand hygiene procedure. Wash access (per above) if patients unable to clean their access.” Observations conducted in the patient treatment area on July 16, 2024 between approximately 8:20 a.m. and 12:15 p.m. and on July 17, 2024 between approximately 11:00 a.m. and 11:30 a.m, revealed the following: Observation #2: On 07/17/23 at approximately 11:00 a.m., patient #6 at station #9, employee #8 began to initiate dialysis treatment. Employee #8 did not wash skin over access with soap and water or antibacterial scrub, prior to evaluating access site, nor verbally confirm that the patient had cleansed the access site. An interview with the facility Clinical Nurse Manager on July 18, 2024 at approximately 1:30 p.m. confirmed the above findings.”
-
Md Resp - Ensure All Adhere To P&P
The inspectors’ words, 366 words
“MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 36372 Based on a review of facility policy/procedure, employee files, medical records, and an interview with facility Clinical Nurse Manager, it was determined the facility failed to ensure TB (tuberculosis) screening was conducted according to facility policy for one (1) of three (3) employee files (EF) reviewed (EF#4) and failed to ensure TB (tuberculosis) screening was conducted according to facility policy for three (3) of five (5) medical records (MR) reviewed (MR#1, MR#3, MR#5). Findings include: A review was conducted of facility policy/procedure on July 18, 2024 at approximately 1:15 p.m. Policy ‘Employee Tuberculosis Testing’ (Setting:IC, HT, IPS) ‘New Hire Screening Policy’ states “ TB testing using the two step tuberculin skin test (TST) method is required upon hire. .........” A review of employee files was completed on July 17, 2024 at approximately 11:40 a.m. Employees date of hire is listed below. EF#4 Date of hire 07/25/22: Documentation provided of first TST administered late on 04/03/24. No documentation of second step TST being administered. Policy ‘Patient Tuberculosis Testing’ (Setting: IC, HT) ‘New Admission Screening’ states “ .... On admission, review the medical records of each patient to determine if they have received TB testing within the last year. ...... Patients who have no documented TB test within the last year will be tested using the TST. ...” A review of medical records was completed on July 18, 2024 at approximately 1:15 p.m. Patients date of admit is listed below. MR#1, date of admit 04/19/24: No documentation provided of a TB test (TST) being conducted upon admit. MR#3, date of admit 02/02/22: Documentation provided of a TB test (TST) being conducted late on 03/02/24. MR#5, date of admit 03/25/24: Documentation provided of a TB test (TST) being conducted late on 04/30/24. An interview with the facility Clinical Nurse Manager on July 18, 2024 at approximately 1:30 p.m. confirmed the above findings.”
-
Mr - Centralize All Info, Each Member Of Idt Has Access
The inspectors’ words, 370 words
“MR-CENTRALIZE ALL INFO;IDT HAS ACCESS CFR(s): 494.170(b)(2) (2) All clinical information pertaining to a patient must be centralized in the patient’s record, including whether the patient has executed an advance directive. These records must be maintained in a manner such that each member of the interdisciplinary team has access to current information regarding the patient’s condition and prescribed treatment. This Standard is not met as evidenced by: 36372 Based on a review of facility policy/procedure, medical records, and an interview with facility Clinical Nurse Manager, it was determined the facility failed to ensure documentation of conductivity of dialysate solution prior to patient treatment for two (2) of three (3) incenter hemodialysis patient medical records (MR) reviewed (MR#2, MR#3). Findings include: A review was conducted of facility policy/procedure on July 18, 2024 at approximately 1:15 p.m. Policy ‘Checking Conductivity and pH of Final Dialysate’ ‘Purpose’ “The purpose of this policy is to provide guidelines to verify final dialysate conductivity and pH prior to initiating hemodialysis treatments and during treatments if required.” ‘Test Verification Prior to Treatment’ .”..... Note: If BlueStar software is enabled for independent conductivity and pH readings, an external meter is not a requirement to measure pre-treatment conductivity and pH. This is only allowed on Bluestar machines with a bibag system.” ..... Documentation’ “Record conductivity and pH readings in the FKC treatment record.” A review of medical records was completed on July 18, 2024 at approximately 1:15 p.m. Patients date of admit is listed below. MR#2, date of admit 02/17/18: This patient is treated on a ‘2008T BlueStar Hemodialysis Machine’ which utilizes bibags (bicarbonate bags). Patient treatment flowsheet dated 07/06/24 was reviewed. No documentation (flow sheet or elsewhere) of the theoretical conductivity value (TCD) and actual conductivity being within normal limits, prior to the start of treatment. MR#3, date of admit 05/16/22: This patient is treated on a ‘2008T BlueStar Hemodialysis Machine’ which utilizes bibags (bicarbonate bags). Patient treatment flowsheet dated 07/12/24 was reviewed. No documentation (flow sheet or elsewhere) of the theoretical conductivity value (TCD) and actual conductivity being within normal limits, prior to the start of treatment. An interview with the facility Clinical Nurse Manager on July 18, 2024 at approximately 1:30 p.m. confirmed the above findings.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jul 19, 2024 | Standard inspection | 6 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Aug 31, 1977.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis and peritoneal dialysis.
- Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
- 21 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 6 dialysis facilities CMS lists in Northampton County, 6 have a star rating from CMS: 1 rated 4 of 5, 4 rated 3 of 5, 1 rated 2 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Davita Palmer Dialysis Center | 3 |
| Davita St Lukes Anderson Dialysis | 3 |
| Fkc Bethlehem | 4 |
| Fkc Slatebelt | 3 |
| Fkc Southside Dialysis | 2 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing