Bcrd Bronx Center for Renal Dialysis
A dialysis facility in Bronx, New York 10472
1010 Underhill Avenue, Bronx, New York 10472. (718) 863-8300.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 3of 5 CMS’s star rating
- 3of 5 patient survey rating
- 3 deficiencies cited in the last three years
- 21 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Aug 9, 2024: a standard inspection.
3 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
3 deficiencies in 1 month of the last 36. Last cited Aug 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Aug 9, 2024: standard inspection1 deficiency
-
Electrical Systems - Essential Electric Syste
The inspectors’ words, 464 words
“Electrical Systems - Essential Electric Syste CFR(s): NFPA 101 Electrical Systems - Essential Electric System Maintenance and Testing The generator or other alternate power source and associated equipment is capable of supplying service within 10 seconds. If the 10-second criterion is not met during the monthly test, a process shall be provided to annually confirm this capability for the life safety and critical branches. Maintenance and testing of the generator and transfer switches are performed in accordance with NFPA 110. Generator sets are inspected weekly, exercised under load 30 minutes 12 times a year in 20-40 day intervals, and exercised once every 36 months for four continuous hours. Scheduled test under load conditions include a complete simulated cold start and automatic or manual transfer of all EES loads, and are conducted by competent personnel. Maintenance and testing of stored energy power sources (Type 3 EES) are in accordance with NFPA 111. Main and feeder circuit breakers are inspected annually, and a program for periodically exercising the components is established according to manufacturer requirements. Written records of maintenance and testing are maintained and readily available. EES electrical panels and circuits are marked and readily identifiable. Minimizing the possibility of damage of the emergency power source is a design consideration for new installations. 6.4.4, 6.5.4, 6.6.4 (NFPA 99), NFPA 110, NFPA 111, 700.10 (NFPA 70) This Standard is not met as evidenced by: 41886 Based on document review and interview, the facility did not ensure the emergency power supply (EPS) was maintained and tested in accordance with NFPA 110, Standard for Emergency and Standby Power Systems, 2012 Edition. Findings: As per NFPA 110, the generator shall be exercised annually, with supplemental loads not less than 50 percent of the EPS nameplate kW rating, for 30 continuous minutes; and not less than 75 percent of the EPS nameplate kW rating, for 1 continuous hour, for a total test duration not less than 1.5 continuous hours. The facility’s Generator Test Logs, dated from 01/2023 to 08/2024, revealed that the generator failed the monthly 30% load tests exercised from 01/2023 to 08/2024. For the generator named GENERAC (Model SD200), the nameplate kilowatt (kW) rating was 200 kW. The load reached 17 kW during each month’s load test from 2023 to 2024. There was no documented evidence that the annual 1.5 hours load test was performed after the failed monthly 30% load tests. During interview of Staff A (Maintenance Director) on 8/9/2024 at 1:05 PM, Staff A acknowledged that the facility’s generator failed the monthly 30% load test. Staff A stated that they were not aware of the additional requirement to conduct an annual load test in such cases. The facility failed to ensure the maintenance and testing of the emergency power supply was conducted in accordance with NFPA 110.”
Aug 7, 2024: standard inspection2 deficiencies
-
Ic - Wear Gowns, Shields/Masks; Staff Not Eat/Drink In Tx Area
The inspectors’ words, 403 words
“IC-GOWNS, SHIELDS/MASKS-NO STAFF EAT/DRINK CFR(s): 494.30(a)(1)(i) Staff members should wear gowns, face shields, eye wear, or masks to protect themselves and prevent soiling of clothing when performing procedures during which spurting or spattering of blood might occur (e.g., during initiation and termination of dialysis, cleaning of dialyzers, and centrifugation of blood). Staff members should not eat, drink, or smoke in the dialysis treatment area or in the laboratory. This Standard is not met as evidenced by: 28297 Based on observation, interview and policy review, the facility failed to ensure that visitors in the treatment area wore Personal Protective Equipment (PPE) as required for one of three survey days. The failure for visitor to wear PPE as required had the potential for exposure to bloodborne pathogens and this could affect 115 in-center patients. Findings include: Observation on 08/06/24 at 12:15 PM revealed Certified Clinical Hemodialysis Technician (CCHT) 1 was at Station 11 putting on Patient (P) 11 via fistula (a permanent access that connects a vein and artery used for hemodialysis) in the left arm. A visitor (sitter) was sitting in a chair the entire time without any protective grown. During an interview with CCHT1 he/she stated they did not know the visitor needed to wear a protective gown. Observation on 08/06/24 at 12:25 PM the CCHT2 at Station 6 putting on P12 via fistula in the left arm. A visitor was sitting in a chair the entire time without any protective grown. During an interview with CCHT6 he/she stated they did not know the visitor needed to wear a protective gown. During an interview on 08/07/24 at 11:20 AM the Nurse Manager confirmed that the visitors did not have on PPE and that visitors who are in the treatment area during initiation and termination of treatment should have on protective gowns to prevent exposure to bloodborne pathogens. Review of the facility’s policy titled, “Visitor Policy,” effective 03/2020, indicated, “ ...Visitors may be allowed in the hemodialysis treatment area at the discretion of the dialysis Nurse Manager or Charge Nurse. Visitors are not allowed in the treatment area during initiation and termination of the dialysis treatment unless permitted to do so based on the needs of the patient i.e. they are utilized during dialysis to sit with a patient to prevent harm ...The visitor should be offered an impervious gown while in the treatment area. The gown should be fully closed in front ...””
-
Pe - Equipment Maintenance - Manufacturer’S Dfu
The inspectors’ words, 390 words
“PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 28297 Based on observations, interview, and Manufacture Directions for Use, the facility failed to follow the recommendations for dialysis (an artificial means of kidney function that removes the waste and excess fluid from the blood by passing it through a filter) treatments by not maintaining the arterial drip chambers (a pressure and air monitoring component of the dialysis bloodline tubing) fluid levels at 85-95% full for two of three survey days. Failure to follow the Manufacture Directions for Use (DFU) had the potential to result in equipment malfunction and/or failure and negatively impact the safety and wellbeing of the 115 patients receiving dialysis treatments in this facility. Findings include: 1. Observation of the hemodialysis treatment area on 08/05/24 revealed the following: At 12:30 PM, the arterial drip chamber fluid levels were less than 25% full at Stations 3, 4 and 5. Certified Clinical Hemodialysis Technician (CCHT) 3 confirmed the arterial drip chambers were low at Stations 4 and 5 and should be greater than 75 % full to prevent air from getting into the extracorporeal system 2. Observation of the hemodialysis treatment area on 08/06/24 revealed the following: At 1:00 PM the arterial drip chamber at Station 4 and 18 were less than 25 % full. CCHT2 confirmed the arterial drip chambers were low and should be greater than 75 % full to prevent air into the extracorporeal system. During an interview on 08/07/24 at 11:20 PM the Nurse Manager confirmed the arterial drip chambers should always be 75% to 85% full to prevent air from getting into the extracorporeal system. Review of the undated manufacture directions for use (DFU) provided by the facility for “Combi Set True Flow Series Hemodialysis Blood Tubing Set with Priming Set and Transducer Protectors,” indicated, “ ...Prime pre-pump, arterial chamber 85-95% full, post pump arterial and venous chamber 65-75% full ...During Treatment Periodically check the extracorporeal circuit for any evidence of possible Separation or leak. Maintain fluid level in pre-pump arterial chamber at 85%-95% full, post pump arterial and venous chambers at 65-75% full ...””
All 2 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Aug 9, 2024 | Standard inspection | 1 deficiency cited |
| Aug 7, 2024 | Standard inspection | 2 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Jan 19, 2011.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Other.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis and home hemodialysis training.
- Doesn’t offer peritoneal dialysis and a shift starting at 5 p.m. or later.
- 21 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
- In CMS’s survey, patients rate its staff 3 of 5.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Other chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- Patients rate it 3 of 5 in CMS’s survey of in-center hemodialysis patients (43 interviews, Oct 18, 2024 to Jul 11, 2025): 63% rated the facility 9 or 10 out of 10.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | 3 of 5 |
How does it compare nearby?
- Of the 36 dialysis facilities CMS lists in Bronx County, 34 have a star rating from CMS: 1 rated 5 of 5, 8 rated 4 of 5, 13 rated 3 of 5, 5 rated 2 of 5, 7 rated 1 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.