Hearth Record

Davita Sandia Peak Dialysis

A dialysis facility in Albuquerque, New Mexico 87123

10410 Copper Pointe Way NE, Albuquerque, New Mexico 87123. (505) 299-0657.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 5 deficiencies in 1 month of the last 36. Last cited Jul 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jul 18, 2024: a standard inspection.

5 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

5 deficiencies in 1 month of the last 36. Last cited Jul 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

5 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jul 18, 2024: standard inspection5 deficiencies
  • Mixing Systems - Permanent Record/Verification Testing

    The inspectors’ words, 529 words

    “MIXING SYSTEMS-PERM RECORD/VERIF TEST CFR(s): 494.40(a) 5.4.4.1 Mixing systems: perm record/verification testing In addition to container labeling, there should be permanent records of batches produced. These records should include the concentrate formula produced, the volume of the batch, the lot numbers of powdered concentrate packages, the manufacturer of the powdered concentrate, the date and time of mixing, any test results, the person performing the mixing, the person verifying mixing and test results, and the expiration date (if applicable). 6.4.1 Mixing systems Acid and bicarbonate concentrates may be tested by using conductivity or by using a hydrometer. Concentrates should not be used or transferred to holding tanks or distribution systems until all tests are completed. The test results and verification that they meet all applicable criteria should be recorded and signed by the individuals performing the tests. This Standard is not met as evidenced by: 35949 Based on observation, interview, mix log review, and facility policy review, the facility failed to perform and/or document test results in a permanent record, after reconstituting and prior to distribution of bicarbonate solution, when batches of bicarbonate solution were produced 65 of 65 times. The facility also failed to have a policy stipulating the expected ranges used to verify the correct solution mixture to prevent distribution of mixtures testing outside those ranges. Failure to perform testing and failure to have a policy which included the expected ranges to verify correct mixing had the potential to negatively impact the dialysate necessary for dialysis and potentially impact the safety and well-being of the 23 in-center patients who received dialysis treatments at the facility. Findings included: A facility policy titled, “Bicarbonate Concentrate System Mixing,” revised 04/2024, indicated, “13. Preparation of bicarbonate concentrate is documented on a log at the time of preparation and verified by a second teammate prior to dispensing. The log should include: * The concentrate formula produced * The number and expiration date of bags used for that batch- * The volume of the batch * The lot numbers of powdered concentrate packages * The date and time of mixing * Any verification test results - if required by the manufacturer, verification of conductivity of the bicarbonate concentrate used at the facility.” During an interview on 07/16/2024 at 10:43 AM, the Biomedical Technician stated the reconstituted bicarbonate solution was not checked prior to distribution, and testing was performed only at the dialysis machines in the treatment area prior to initiation of each dialysis treatment. The Biomedical Technician further stated there was no testing device available and/or utilized in the mixing area. During an observation of the bicarbonate mixing area and interview on 07/16/2024 at 2:00 PM, Patient Care Technician (PCT) #6 stated there was no device in the area. PCT #6 stated she did not test the reconstituted bicarbonate solution prior to distribution. During an interview on 07/18/2024 between 2:20 PM and 3:10 PM, the Medical Director stated the facility was expected to follow federal regulations for testing of the bicarbonate solution prior to distribution. A “Bicarb [bicarbonate] Mix Log,” for the date range 04/13/2024 to 07/16/2024, revealed bicarbonate solution was mixed 65 times with no documentation of the reconstituted bicarbonate solution test results.”

    Rule V0229. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 500 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 35949 Based on observation, interview, manufacturer’s directions for use (DFU) review, and facility policy review, the facility failed to follow the bloodline manufacturer’s DFU during dialysis treatments by not maintaining the venous drip chamber fluid levels at 3/4 full during 4 of 4 observations. Failure to follow the bloodline manufacturer’s DFU had the potential to result in equipment malfunction and/or failure and negatively impact the safety and wellbeing of the 23 patients who received dialysis treatments in the facility. Findings included: A facility policy titled, “Pre-Intra-Post Treatment Data Collection, Monitoring and Nursing Assessment,” revised 04/2024, indicated, “e. The arterial and venous drip chamber levels should be observed and adjusted as needed.” The manufacturer’s DFU titled, “Nipro Instructions for use ... Nipro Set Blood Tubing Set,” revised 03/22/2019, indicated, “Dialysis Treatment Precautions: 1. Before initiating dialysis treatment, check the following: a. Drip chambers are in the upright position and have the fluid level at ¾ full.” In addition, the DFU indicated, “b. Periodically check fluid level in drip chamber and adjust if required.” An observation of the hemodialysis treatment area on 07/16/2024 at 10:15 AM revealed the venous drip chamber fluid levels were greater than ¾ full in Stations 1, 2, 4, 5, 8, and 10. An observation of the hemodialysis treatment area on 07/18/2024 at 10:00 AM revealed the venous drip chamber fluid levels were greater than ¾ full in Stations 1, 2, 3, 4, 5, 8, 10, and 11. An observation of the hemodialysis treatment area on 07/18/2024 at 10:15 AM revealed the venous drip chamber fluid levels were greater than ¾ full in Stations 1, 2, 3, 4, 5, 8, 10, and 11. An observation of the hemodialysis treatment area on 07/18/2024 at 10:26 AM with the covering Facility Administrator revealed the venous drip chamber fluid levels were greater than ¾ full in Stations 1, 2, 4, 5, 7, 8, 10, and 11. During an interview on 07/18/2024 at 10:26 AM, the covering Facility Administrator confirmed the venous drip chamber fluid levels were not adjusted to ¾ full during the dialysis treatments according to the manufacturer’s DFU. During an interview on 07/18/2024 at 2:20 PM, the Medical Director confirmed the staff were trained and expected to follow the manufacturer’s DFU for adjusting the fluid levels in the drip chambers. During an interview on 07/18/2024 at 3:56 PM, Patient Care Technician #6 stated she was trained to fill the venous drip chamber “to the line” and did not remember being trained according to the manufacturer’s DFU. During an interview on 07/18/2024 at 4:16 PM, Registered Nurse #4 stated he was trained to maintain the venous drip chamber at “the line” during treatments and was not familiar with the manufacturer’s DFU.”

    Rule V0403. Standard-level.

  • Frequency - Initial: 30 Days/13 Tx

    The inspectors’ words, 394 words

    “PA-FREQUENCY-INITIAL-30 DAYS/13 TX CFR(s): 494.80(b)(1) An initial comprehensive assessment must be conducted on all new patients (that is, all admissions to a dialysis facility), within the latter of 30 calendar days or 13 hemodialysis sessions beginning with the first dialysis session. This Standard is not met as evidenced by: 35949 Based on interview, record review, and facility policy review, the facility failed to complete an initial comprehensive assessment conducted by all members of the interdisciplinary team (IDT - a registered nurse, a physician who treated the patient for end stage renal disease, a social worker, and a dietitian [Registered Dietician (RD]) within 30 calendar days after admission, for 1 (Patient #4) of 1 sampled home therapy patients new to dialysis and admitted to the facility within the last 90 days. Failure to complete an initial comprehensive assessment performed by all members of the IDT within 30 calendar days after admission for patients new to dialysis provided opportunities for areas of concern to be unidentified and left unaddressed related to the patients’ plan of care, and had the potential to negatively impact the care and well-being of the 12 patients who received home therapy oversight at the facility. Findings included: A facility policy titled, “Interdisciplinary Team (IDT) Patient Assessment and Plan of Care,” revised 07/2023, indicated, “4. A comprehensive assessment will be conducted on all new patients within 30 calendar days (or 13 outpatient dialysis sessions for hemodialysis) beginning with the first outpatient dialysis treatment or per state guidelines.” A “Patient Summary Report” revealed Patient #4 admitted to the facility on 04/09/2024. A “Comprehensive Assessment Report” revealed a completion date by the RD on 05/22/2024, 43 days from the date of admission. During an interview on 07/17/2024 at 1:51 PM, the covering Facility Administrator confirmed Patient #4’s initial comprehensive assessment was late and past the 30-day timeline. During an interview on 07/18/2024 at 2:27 PM, the RD stated he was not aware of an “exact reason” why Patient #4’s initial comprehensive assessment was past the 30-day timeline for completion. The RD stated he was trained and expected to complete the initial comprehensive assessment within 30 days from the admission date. During an interview on 07/18/2024 at 2:20 PM, the Medical Director confirmed the staff were trained and expected to complete the initial comprehensive assessment on newly admitted patients within 30 days of the admission date.”

    Rule V0516. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 332 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 35949 Based on interview, record review, and facility policy review, the facility failed to monitor patients’ vital signs and/or machine parameters according to their policy for 2 (Patient #2 and Patient #3) of 3 sampled in-center patients. Failure to monitor patients’ vitals and machine parameters according to the facility’s policy provided an opportunity for changes to the patients’ condition during dialysis treatments to be unrecognized and unaddressed and negatively impact the care provided to the 23 patients who received dialysis treatments at the facility. Findings included: A facility policy titled, “Pre-Intra-Post Treatment Data Collection, Monitoring and Nursing Assessment,” revised 04/2024, indicated, “Vital signs and treatment monitoring Non-nocturnal treatments are completed at least every thirty (30) minutes.” 1. Patient #2’s “Treatment Details Report,” dated 06/27/2024, revealed monitoring was not documented for 59 minutes, from 7:58 AM until 8:57 AM. Patient #2’s “Treatment Details Report,” dated 07/09/2024, revealed monitoring was not documented for 60 minutes, from 6:54 AM until 7:54 AM. 2. Patient #3’s “Treatment Details Report,” dated 07/09/2024, revealed monitoring was not documented for 61 minutes, from 2:18 PM until 3:19 PM. During an interview on 07/18/2024 at 8:25 AM, the covering Facility Administrator stated staff were trained and expected to monitor patients every 30 minutes according to the facility’s policy. During an interview on 07/18/2024 at 2:20 PM, the Medical Director confirmed staff were trained and expected to monitor patients every 30 minutes. During an interview on 07/18/2024 at 3:56 PM, Patient Care Technician #6 stated she was trained and expected to perform and document patient monitoring every 30 minutes. During an interview on 07/18/2024 at 4:16 PM, Registered Nurse #4 stated patient monitoring should be performed and documented every 30 minutes as trained and expected.”

    Rule V0543. Standard-level.

  • Mr - Protect Patient Records From Loss/Keep Confidential

    The inspectors’ words, 459 words

    “MR-PROTECT PT RECORDS FM LOSS/CONFIDENTIAL CFR(s): 494.170(a) The dialysis facility must- (1)Safeguard patient records against loss, destruction, or unauthorized use; and (2) Keep confidential all information contained in the patient’s record, except when release is authorized pursuant to one of the following: (i) The transfer of the patient to another facility. (ii) Certain exceptions provided for in the law. (iii) Provisions allowed under third party payment contracts. (iv) Approval by the patient. (v) Inspection by authorized agents of the Secretary, as required for the administration of the dialysis program. This Standard is not met as evidenced by: 35949 Based on observation, interview, contract review, and facility policy review, the facility failed to store medical records in a location that provided security, controlled accessibility, and protected against unauthorized use. Failure to store medical records in a secure location provided an opportunity for unauthorized use and/or access and had the potential to negatively impact the integrity of protected health information for 14 patients who had or were currently receiving care at the facility in the home therapy area. Findings included: A facility policy titled, “Administrative, Technical and Physical Safeguards for Protected Health Information,” reviewed 06/2022, indicated, “1. All Teammates of [name] are responsible for ensuring that physical access control and other administrative, technical and physical safeguards are implemented to limit physical access to the facilities and to protect PHI [protected health information] against unauthorized access.” In addition, the policy indicated, “i. Medical Records must be locked in a drawer or filing cabinet when not in use and at the end of each workday.” A facility contract titled, “Facilities Management Services,” dated 03/11/2013, indicated, “Assumptions” that included “Hallways, corridors, stairwells” and “Cleaning hours - cleaning performed: Only on days of operation, After clinic has completed the day operations.” During an observation on 07/16/2024 at 10:10 AM of the home therapy area, 14 medical records were observed on an open wheeled metal shelving cart at the end of the hallway at the nurses’ station. During an interview on 07/16/2024 at 10:35 AM, Patient Care Technician #7 stated the housekeeping staff cleaned the facility “after [business] hours.” During an interview on 07/17/2024 at 8:00 AM, both the covering Facility Administrator and Registered Nurse (RN) #5 confirmed there were 14 medical records (12 current patients and two additional patients) stored in an open wheeled metal shelving cart at the end of the hallway near the nurses’ station in the home therapy area. Both the covering Facility Administrator and RN #5 confirmed the medical records contained protected health information and were not protected from unauthorized access by the housekeeping staff that presented to the facility after business hours. During an interview on 07/18/2024 at 2:20 PM, the Medical Director confirmed medical records should be securely stored.”

    Rule V0727. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jul 18, 2024Standard inspection5 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Apr 23, 2018.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis and peritoneal dialysis.
  • Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
  • 12 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 17 dialysis facilities CMS lists in Bernalillo County, 16 have a star rating from CMS: 1 rated 4 of 5, 5 rated 3 of 5, 8 rated 2 of 5, 2 rated 1 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.