322548 - Liberty Rio Rancho (Fmc)
A dialysis facility in Albuquerque, New Mexico 87114
5751 Mcmahon Blvd NW, Albuquerque, New Mexico 87114. (505) 899-1019.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 2of 5 CMS’s star rating
- 3of 5 patient survey rating
- 2 deficiencies cited in the last three years
- 19 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Feb 20, 2025: a standard inspection.
2 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
2 deficiencies in 1 month of the last 36. Last cited Feb 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Feb 20, 2025: standard inspection2 deficiencies
-
Ic - Wear Gloves/Hand Hygiene
The inspectors’ words, 629 words
“IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 50656 Based on observations, staff interview and record review, the facility failed to ensure adherence to infection control practices when a staff member did not perform hand hygiene and change gloves after touching a dialysis machine then cannulating (inserting a dialysis needle into the patient’s fistula) a patient’s fistula (a surgically created connection between a vein and an artery, usually in the arm which allows for easier access for a large amount of blood flow for receiving dialysis treatment) to begin hemodialysis [a medical procedure that filters and cleans the blood when the kidney can no longer do so] treatment for 1(P(patient) 7) of 16 (P5, P6, P8, P9, P18, P19, P29, P30, P31, P32, P33, P34, P35, P36, P37, and P38) patients receiving hemodialysis. This deficient practice could likely lead to the increased risk of bloodstream infections [an infection where harmful germs enter the blood, possibly causing serious illness or death] and cross contamination (the process where bacteria or other microorganisms are unintentionally transferred from one object to another, with harmful effects) which may cause complications leading to poor patient health outcomes for all patient receiving hemodialysis treatment at the facility. The findings are: A. During an observation on 02/18/25 at 9:35 am in the facility HD treatment room, S(staff)11, clinical, touched a HD machine computer screen with exam gloves on then without removing the contaminated gloves and without performing hand hygiene, S11 cleaned P7’s fistula site then cannulate the patient’s fistula to begin HD treatment. B. During an interview on 02/18/25 at 9:41 am with S11, clinical, S11 was asked what the facility policy is for hand hygiene prior to cannulating a patient’s fistula for HD treatment, S11 replied “ I’m supposed to wash my hands. Oh, sorry I didn’t do that.” C. Record review of the facility’s policy titled “Hand Hygiene,” dated 11/06/2023 revealed the following: 1. Purpose: The purpose of this policy is to prevent transmission of pathogenic microorganisms to patients and staff through cross contamination [the transfer of harmful bacteria from one person, object or place to another]. 2. Responsibility: All staff, patient care givers, including physicians and non-physician practioners, social workers, dieticians, and any other indirect patient care staff must follow the same requirements for and hygiene. 3. Hand hygiene includes either washing hands with soap and water or using a waterless alcohol-based antiseptic hand rub with 60-90% alcohol content. Drying effects of alcohol can be counteracted by addition of emollient or humectants, e.g. 1-3% glycerol. - Hands will be Decontaminated [sic] using alcohol-based hand rub or by washing hands with antimicrobial soap and water. -Before and after direct contact with patients. -Before performing any invasive procedure such as vascular access cannulation or administration of parenteral medications [medications or fluids given directly into the bloodstream though a needle]. -After contact with inanimate objects near the patient. 4. Procedure for Decontaminating Hands with Alcohol Based Hand Rubs: Follow the procedure outlined below when decontaminating hands with alcohol-based hand rubs: Step a. If gloves are worn, remove and discard gloves in an appropriate waste container. Exposes the skin for decontamination [sic]. b. Apply alcohol-based hand rub to the palm of one hand using the amount recommended by the product manufacturer. Adequate amount of product must be used for maximum effectiveness. c. Rub hands together covering all surfaces of the hands and fingers, until hands are dry. -Allowing alcohol to dry completely allows adequate contact time to kill germs, allows alcohol to evaporate, and prevents risk of igniting flames due to alcohol’s flammable properties.”
-
Manage Volume Status
The inspectors’ words, 619 words
“POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 50656 Based on observations, record reviews and staff interviews, the facility failed to ensure that the arterial drip chambers [small, transparent container that holds blood coming from the patient’s artery before it is filtered by the dialysis machine] were filled to the required level of 85% to 95% full for all patients during hemodialysis treatments for 3 (P[patients]1, P2, and P3) of 21 (P1, P2, P3, P23, P25, P57, P58, P59, P60, P61, P62, P63, P64, P65, P66, P67, P68, P69, P70, P71, and P72 ) patients receiving hemodialysis treatments. This deficient practice could lead to the risk of air embolism, [a condition where air bubbles enter the bloodstream, and may cause serious health issues like heart of brain damage] blood clotting, and inefficient blood flow which can compromise patient safety and dialysis effectiveness for all patients receiving hemodialysis treatments at the facility. The findings are: A. During an observation on 02/17/25 at 1:37 pm, arterial drip chamber for P1 was filled below 75% full, below the required fill level of between 85% to 95% full per facility policy. B. During an observation on 02/17/25 at 1:37 pm, arterial drip chamber for P2 was filled below 75% full, below the required fill level of between 85% to 95% full per facility policy. C. During an observation on 02/17/25 at 1:37 pm, arterial drip chamber for P3 was filled below 75% full, below the required fill level of between 85% to 95% full per facility policy. D. During an interview on 02/17/25 at 1:41 pm with S(staff)1, clinical, when asked what the facility’s policy and procedure was for minimum arterial drip chamber fill level, S1 replied “They have to be 3/4th full (75% full).” When S1 was asked if the drip chamber for P1 was at the require level of 3/4ths full, S1 responded “No.” E. During an interview on 02/17/25 at 1:41 pm with S1, clinical, when asked what the facility’s policy and procedure was for minimum arterial drip chamber line, S1 replied “They have to be 3/4ths full (75% full).” When S1 was asked if the drip chamber for P2 was at the require level of 3/4ths full, S1 responded “No.” F. During an interview on 02/17/2025 at 1:47 pm with S1, clinical, when asked what the facility’s policy and procedure was for minimum arterial drip chamber line, S1 replied “They have to be 3/4ths full (75% full) .” When S1 was asked if the drip chamber for P3 was at the require level of 3/4ths full, S1 responded “No.” G. Record review of the facility’s policy titled “Initiation of Treatment Using an Arteriovenous Graft [a surgically created connection between an artery and a vein, used in dialysis to make it easier to access the bloodstream for treatment] or Fistula [a surgically created connection between an artery and a vein to to make receiving dialysis easier]and Optiflux Single Use Ebeam Dialyzer [a type filter that works as an artificial kidney used in dialysis treatments]” on page 5 of 7, dated 05/06/2024 revealed the following: Prior to starting the blood pump, verify the following: 1. All connections are secure 2. Dialysate lines are attached properly to the dialyzer. 3. There is at least 300 mL [a unit of volume primarily used to measure liquid] of saline in the saline bag and the saline line is double clamped. 4. Any unused administration lines are clamped. 5. The arterial chamber is 85 - 95% full.....”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Feb 20, 2025 | Standard inspection | 2 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Dec 25, 2015.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis and a shift starting at 5 p.m. or later.
- Doesn’t offer peritoneal dialysis and home hemodialysis training.
- 19 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
- In CMS’s survey, patients rate its staff 2 of 5.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- Patients rate it 3 of 5 in CMS’s survey of in-center hemodialysis patients (33 interviews, Oct 18, 2024 to Jul 11, 2025): 65% rated the facility 9 or 10 out of 10.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 2 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | 3 of 5 |
How does it compare nearby?
- Of the 17 dialysis facilities CMS lists in Bernalillo County, 16 have a star rating from CMS: 1 rated 4 of 5, 5 rated 3 of 5, 8 rated 2 of 5, 2 rated 1 of 5.
- CMS rates this one 2 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing